If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-131-20537 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.544467,"lon":-76.144267,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Wyoming | |
Municipality: Forkston Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 152119 | |
Farm/Lease Name: OTTEN 2H | |
License Status: Active | |
Spud Date: 2017-02-18 | |
Permit Date: 2016-11-21 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.544467 | |
Longitude: -76.144267 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2017-05-29 | 2017-06-01 | 8724 | 3,809,280.0 | 54000 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | HYDROCHLORIC ACID | Halliburton | Solvent | Listed Below | ||||
SAND-COMMON WHITE - 100 MESH | Halliburton | Proppant | Listed Below | |||||
FR-76 | Halliburton | Friction Reducer | Listed Below | |||||
Fresh Water | Operator | Base Fluid | Listed Below | |||||
Ingredients | Listed Above | Listed Above | Listed Below | |||||
BE-9 | Halliburton | Biocide | Listed Below | |||||
HAI-150E | Halliburton | Corrosion Inhibitor | Listed Below | |||||
LCA-1 | Halliburton | Solvent | Listed Below | |||||
Tributyl tetradecyl phosphonium chloride | 81741-28-8 | 10 | 0.00362287 | 1339 | ||||
Crystalline silica, quartz | 14808-60-7 | 100 | 12.5557 | 4,640,510.0 | ||||
Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.0286048 | 10573 | ||||
Acrylamide acrylate copolymer | Proprietary | 30 | 0.0286048 | 10573 | ||||
Hydrochloric acid | 7647-01-0 | 15 | 0.21521 | 79542 | ||||
Diammonium phosphate | 7783-28-0 | 5 | 0.0011608 | 430 | ||||
Organic phosphonate | Proprietary | 60 | 0.0139296 | 5149 | ||||
Non-hazardous food substance | Proprietary | 100 | 0.000146107 | 54 | ||||
Water | 7732-18-5 | 100 | 85.8543 | 31,731,200.0 | ||||
Inorganic salt | Proprietary | 30 | 0.0286048 | 10573 | ||||
Water | 7732-18-5 | 100 | 1.54213 | 569964 | ||||
Ammonium chloride | 12125-02-9 | 30 | 0.0069648 | 2575 | ||||
LP-65 MC | Halliburton | Scale Inhibitor | Listed Below | |||||
SAND-PREMIUM WHITE-30/50 | Halliburton | Proppant | Listed Below |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2017 | SWN PROD CO LLC | 637,293.00 | 198 | 0.00 | 0 | 0.00 | 0 |
2018 | SWN PROD CO LLC | 1,279,584.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 296,660.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2017-M02 | Drill Cuttings (in Tons) RWC 810 | 174.05 Tons | LANDFILL | 101247 |
2017-M03 | Drill Cuttings (in Tons) RWC 810 | 1,672.72 Tons | LANDFILL | 100933 |
2017-M03 | Drilling Fluid Waste (in Barrels) RWC 803 | 324.00 Bbl | REUSE (AT WELL PAD) | |
2017-M03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 170.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M04 | Drill Cuttings (in Tons) RWC 810 | 1,873.83 Tons | LANDFILL | 100933 |
2017-M04 | Drilling Fluid Waste (in Barrels) RWC 803 | 450.00 Bbl | REUSE (AT WELL PAD) | |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 323.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M05 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 430.00 Bbl | REUSE (AT WELL PAD) | |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 1,786.66 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M06 | Produced Fluid (in Tons) RWC 802 | 39.72 Tons | LANDFILL | THR029 |
2017-M06 | Synthetic Liner Materials (in Tons) RWC 806 | 11.20 Tons | LANDFILL | 101247 |
2017-M06 | Unused Fracturing Fluid Waste (in Barrels) RWC 805 | 259.66 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M06 | Unused Fracturing Fluid Waste (in Tons) RWC 805 | 13.33 Tons | LANDFILL | THR029 |
2017-M07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 74.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 3,507.33 Bbl | SURFACE IMPOUNDMENT | 826342 |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 2,446.67 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 1,688.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 151.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M08 | Synthetic Liner Materials (in Tons) RWC 806 | 5.39 Tons | LANDFILL | 100933 |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 873.67 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M09 | Produced Fluid (in Tons) RWC 802 | 3.24 Tons | LANDFILL | 301358 |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 455.67 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M11 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 105.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 449.67 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 500.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 217.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M01 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 45.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 471.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M01 | Synthetic Liner Materials (in Tons) RWC 806 | 8.33 Tons | LANDFILL | 101247 |
2018-M02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 27.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 37.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 172.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 156.33 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 203.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 39.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 81.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 103.33 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 111.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 131.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 38.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 38.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M09 | Other Oil & Gas Wastes (in Tons) RWC 899 | 111.67 Tons | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 73.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 256.67 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 43.67 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 496.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 43.33 Bbl | SURFACE IMPOUNDMENT | 826342 |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 362.67 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 231.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 202.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2563329 | Primary Facility | 2017-02-21 | Drilling/Alteration | No Violations Noted | |
2567707 | Primary Facility | 2017-03-02 | Drilling/Alteration | No Violations Noted | |
2580161 | Primary Facility | 2017-04-04 | Drilling/Alteration | No Violations Noted | |
2581580 | Primary Facility | 2017-04-11 | Drilling/Alteration | No Violations Noted | |
2584136 | Primary Facility | 2017-04-11 | Drilling/Alteration | No Violations Noted | |
2584466 | Primary Facility | 2017-04-18 | Drilling/Alteration | No Violations Noted | |
2639886 | Primary Facility | 2017-09-26 | Routine/Complete Inspection | No Violations Noted | Arrived on location at: 10:30. Weather: Clear, warm, ~ 75 degs. On location to perform routine inspection of wells on pad. This pad has a total of (3) wells on pad. All wells were in production at time of inspection. All wells were producing through tubing. Tubing production pressures were being monitored by wireless sending units with LED readouts. Tubing pressures were: 1H: 1170.6 psi., 2H: LED readout not working., 3H: 1169.9. Production line pressures were being monitored by "PCS High-Low" control panels. Prod. line pressures were: 1H: 1164 psi., 2H: 1162 psi., 3H: 1165 psi. All wells (9x5) annuli vents were plumbed to surface. These vents were SI. Taylor plugs were present for pressure checks using a crystal gauge. No gauges were present to check pressures at these annuli at time of inspection. (3) GPU units were present, one for each well. The Total Flow Control panel by GPUs was password protected and inaccessible at time of inspection. No obvious concerns were noted at wells or production units. (15) |
2819648 | Primary Facility | 2019-03-12 | Site Restoration | No Violations Noted | I arrived onsite at 1255 to conduct a site restoration inspection of the pad. I was accompanied by Jon Sassi (EPS-DEP).
While onsite, we observed staining on an unlabeled tank near the compressor facility that is reportedly used for oil associated with the compressor. The fluid in secondary containment had a foamy oily substance floating on top. The pad surface was also stained in the immediate vicinity of the tank. Mr. Sassi called Mike Deming (SWN) to notify him of the release. Mr. Deming stated that SWN had known about the release, and that it had occurred several days earlier but was not reported due to SWN's assertion that it was under 5 gallons. Operator, the Department requests that you inspect the area and begin remediation activities immediately. Additionally, please ensure all tanks are labeled with the name of the substance they contain as well as remove any standing fluid in the tank's containment. Violations were noted during this inspection. Please contact me with any questions. |
2836165 | Primary Facility | 2019-01-24 | Routine/Complete Inspection | No Violations Noted | I arrived onsite at 1423 to perform a routine complete inspection of the pad. The weather was 36 degrees F with moderate snow beginning to accumulate, cloudy skies, and a steady moderate wind.
The lengthy access road appeared to be in good condition with no obvious areas of accelerated erosion and sedimentation. Pad was not plowed and most of the pad surface was covered in an icy slush. I noticed that some areas of the access slope contained exposed erodible material on the steep fill slope, providing a potential source for accelerated erosion and sedimentation. Operator, please inspect the area and determine if they need to be reseeded/mulched when weather permits. I also noted that the one (1) produced water tank located near the GPUs on the pad was not labeled. As I continued my inspection, I observed that there was another tank on the pad located next to the compressor facility that was also unlabeled. Operator, please inspect the area and determine what steps need to be taken to remedy the aforementi |
For data sources see[7]