If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-21277 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.346411,"lon":-76.958839,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Gamble Township | |
Operator Name: INFLECTION ENERGY (PA) LLC | |
Well Pad ID: 149762 | |
Farm/Lease Name: STUNNER SMITH 1H | |
License Status: Active | |
Spud Date: 2013-09-08 | |
Permit Date: 2013-08-08 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.346411 | |
Longitude: -76.958839 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-08-19 | 2014-08-23 | 9328 | 8,653,180.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | AI-301 | U.S. Well Services | Acid Corrosion Inhibitors | Hydrogen Chloride | 7647-01-0 | 10 | 0.00005000 | 42.5674 |
Polyethylene polyamine | 68603-67-8 | 10 | 0.00004000 | 36.9529 | ||||
Diethylene Glycol | 111-46-6 | 30 | 0.00013 | 123.188 | ||||
Methenamine | 100-97-0 | 20 | 0.00011 | 97.6114 | ||||
Coco amine | 61791-14-8 | 5 | 0.00002000 | 16.8802 | ||||
K-BAC 1020 | U.S. Well Services | Anti-Bacterial Agent | 2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 20 | 0.00774 | 7064.53 | |
Water | 7732-18-5 | 20 | 0.00316 | 2882.3 | ||||
Polyethylene Glycol | 25322-68-3 | 50 | 0.00884 | 8070.45 | ||||
Sand | U.S. Well Services, LLC | Proppant | Crystalline Silica, quartz | 14808-60-7 | 100 | 8.47312 | 7,738,510.0 | |
LGC-15 | U.S. Well Services | Gelling Agents | Petroleum Distillates | 64742-47-8 | 60 | 0.00097 | 882.18 | |
Suspending agent (solid) | 14808-60-7 | 3 | 0.00001000 | 6.57 | ||||
Guar Gum | 9000-30-0 | 50 | 0.00012 | 109.5 | ||||
Surfactant | 68439-51-0 | 3 | 0.00006000 | 55.8897 | ||||
WFRA-405 | U.S. Well Services | Friction Reducer | Ammonium Chloride | 12125-02-9 | 5 | 0.00348 | 3181.29 | |
Water | 7732-18-5 | 40 | 0.02787 | 25450.3 | ||||
Ethoxylate Alcohol | 68551-12-2 | 5 | 0.00348 | 3181.29 | ||||
Petroleum Distillates | 64742-47-8 | 22 | 0.01234 | 11268.1 | ||||
Anionic Polyacrylamide | 62649-23-4 | 40 | 0.02787 | 25450.3 | ||||
AP One | U.S. Well Services | Gel Breakers | Ammonium Persulfate | 7727-54-0 | 100 | 0.00002000 | 22 | |
HCL Acid (12.6%-17.5%) | U.S. Well Services, LLC | Bulk Acid | Hydrogen Chloride | 7647-01-0 | 17.5 | 0.03652 | 33356.7 | |
Water | 7732-18-5 | 87.4 | 0.0878 | 80192.2 | ||||
30/50 EconoProp | U.S. Well Services | Ceramic Proppant | Silicon Dioxide | 7631-86-9 | 35 | 0.47385 | 432768 | |
Silica Crystalline-Cristobalite | 14464-46-1 | 20 | 2.25823 | 2,062,450.0 | ||||
Mullite | 1302-93-8 | 85 | 9.59749 | 8,765,410.0 | ||||
Water | Inflection Energy | Base Fluid | Water | 7732-18-5 | 100 | 78.9392 | 72,095,300.0 | |
SI-1100 | U.S. Well Services | Scale Inhibitor | 2-Phosphonobutane 1,2,4 tricarboxylic salt | 37971-36-1 | 10 | 0.00251 | 2293.73 | |
Potassium salt of diethylene triamine penta (methylene phosphonic acid) |
15827-60-8 | 10 | 0.00263 | 2400.42 | ||||
Di Water | 7732-18-5 | 80 | 0.01558 | 14224.7 | ||||
Acrylic polymer | 52255-49-9 | 5 | 0.00097 | 889.044 | ||||
bis (hexamethylene) tramine penta (methylene phosphonic acid) - phosphate acid |
40623-75-4 | 10 | 0.00224 | 2044.8 | ||||
Ethylene Glycol | 107-21-1 | 40 | 0.0088 | 8036.96 | ||||
hexamethylenediamine tetra (methylene phosphonic acid) | 38820-59-6 | 10 | 0.00243 | 2222.61 | ||||
Copolymer of Maleic and Acrylic acid | 26677-99-6 | 10 | 0.0023 | 2098.14 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2016 | INFLECTION ENERGY (PA) LLC | 1,021,981.00 | 184 | 0.00 | 0 | 0.00 | 0 |
2017 | INFLECTION ENERGY (PA) LLC | 2,479,874.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2018 | INFLECTION ENERGY (PA) LLC | 1,889,071.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | INFLECTION ENERGY (PA) LLC | 409,597.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 3,866.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S01 | Waste Water Treatment Sludge (in Tons) RWC 804 | 64.78 Tons | LANDFILL | 301626 |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 567.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 132.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 87.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 60.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 116.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 52.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 137.50 Bbl | REUSE (AT WELL PAD) | |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 60.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 52.50 Bbl | REUSE (AT WELL PAD) | |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 132.00 Bbl | REUSE (AT WELL PAD) | |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 206.00 Bbl | REUSE (AT WELL PAD) | |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
2018-M04 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 60.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018-M05 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 60.00 Bbl | REUSE (AT WELL PAD) | |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 120.00 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 85.00 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 180.00 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 165.00 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 60.00 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 300.00 Bbl | REUSE (AT WELL PAD) | |
2018-M10 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 360.00 Bbl | REUSE (AT WELL PAD) | |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 180.00 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 180.00 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 530.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 165.00 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 120.00 Bbl | REUSE (AT WELL PAD) | |
2019-M03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 66.25 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2209512 | Primary Facility | 2013-10-02 | Routine/Complete Inspection | No Violations Noted | |
2246455 | Primary Facility | 2014-02-19 | Routine/Complete Inspection | No Violations Noted | |
2247493 | Primary Facility | 2014-02-20 | Drilling/Alteration | No Violations Noted | |
2254931 | Primary Facility | 2014-03-18 | Routine/Partial Inspection | No Violations Noted | |
2261495 | Primary Facility | 2014-04-02 | Routine/Partial Inspection | No Violations Noted | H&P 354 onsite drilling the 081-21286 well, modular tank onsite storing flowback. No Vio. |
2435543 | Primary Facility | 2015-12-17 | Routine/Complete Inspection | No Violations Noted | 081-21277: Department records indicate well 081-21277 (Stunner Smith 1H) was Proposed but never materialized yet the Department received a well record for the well. The well was not located on the well site. |
2605757 | Primary Facility | 2017-06-20 | Administrative/File Review | Violation(s) Noted | Administrative Inspection entered for the purpose of entering an Enforcement Record (NOV).
VIOLS closed (CRCTD) 12/15/2017 upon issuance of permit modification. |
2686985 | Primary Facility | 2018-01-23 | Routine/Complete Inspection | No Violations Noted | Arrived at 13:15. Weather: warm, sunny, T¿s in upper 40s. There are 7 wells. The Stunner Smith 1H and Ryder Park 1H are in production. Stunner Smith 2H and 3H are top-holed. SS 2H: TD 6692¿ with a plug from 6648¿ to 6144. IC casing to 3018¿. SS 3H: TD 6621¿, IC casing to 3007. For both wells, methane was leaking (few bubbles, slow rate) from the join between the intermediate vent pipe and the intermediate casing (Altair 5X gas meter calibrated on 1/1/23/17). Notified Greg Malekos of the leaks. For the SS 6H, a plugged conductor, all that was visible was a gravel filled cellar. For the SS 4H and SS 5H, also plugged, the cellars were filled with water. The surface hole locations for the plugged conductors were updated in eFACTS to address locational discrepancies observed in the field. |
2696675 | Primary Facility | 2018-02-22 | Follow-up Inspection | No Violations Noted | Arrived at 7:40. Weather: rainy, temperatures in low 40's. There are 7 wells. The Stunner Smith 1H and Ryder Park 1H are in production. Stunner Smith 2H and 3H are top-holed. SS 2H: TD 6692' with a plug from 6648' to 6144'. IC casing to 3018'. SS 3H: TD 6621', IC casing to 3007. This is a follow up IR to see if methane is still leaking from the join between the intermediate vent pipe and the intermediate casing. It was. Will schedule follow-up with Inflection. For the SS 6H, a plugged conductor, all that was visible was a gravel filled cellar. For the SS 4H and SS 5H, also plugged, the cellars were filled with water. |
2818960 | Primary Facility | 2018-12-26 | Routine/Complete Inspection | No Violations Noted | A H&P rig is drilling on the Smith Well pad. The Department representative did not locate the rig manager so Department could not determine which well was being drilled.
The site had a primary containment overlaid with wood plank rig matting with beveled edges (see photo). All materials held on containment and within secondary containment. The overall site conditions were clean and well organized. No leaks or spills detected. No violations. |
2840550 | Primary Facility | 2019-02-14 | Routine/Complete Inspection | No Violations Noted | I met Ross Drnjevich of Inflection on the site. H&P 521 on location, drilling the 2HN well at 8300'. The chemical containment appeared to be in good condition, but also contained several inches of snow and ice. The secondary containment for the mud tanks had been bolted on with wood strips on the inside of the containment in the back, approximately 4-5" down from the top. Although it is unlikely that this brought the containment volume below 110% of the volume of the tanks, I still recommended to Ross that these liners be attached on the outside of the berms. Meltwater had built up to 3-4" deep on the backside of the pad, and Ross told me he would have it vacced. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2605757 | 788463 | 2017-06-20 | 2017-12-15 | OGA3211(F1) | Administrative | Well was intentionally drilled at a Surface Hole Location (SHL) other than the approved SHL on the well permit, resulting in the actual SHL being approximately 122 feet from the permitted SHL. |
2605757 | 788464 | 2017-06-20 | 2017-12-15 | 78a12 | Administrative | The well was not drilled in accordance with the approved well permit. The actual SHL is approximately 122 feet from the permitted SHL. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
788463 | 354434 | NOV - Notice of Violation | 2017-12-15 | ||||
788464 | 354434 | NOV - Notice of Violation | 2017-12-15 |
For data sources see[7]