Well Details

Well ID: 37-105-21239
Loading map...
Country: United States
State: Pennsylvania
County: Potter
Municipality: Keating Township
Operator Name: MINARD RUN OIL CO
Well Pad ID:
Farm/Lease Name: WARRANT 3914 1906
License Status: Regulatory Inactive Status
Spud Date: 2006-10-05
Permit Date: 2006-07-07
Unconventional Well: N
Configuration: Vertical Well
Latitude: 41.713909
Longitude: -78.151608

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2006 0.00 0 0.00 0 0.00 0
2007 0.00 0 0.00 0 0.00 0
2008 PA GEN ENERGY CO LLC 4,869.11 365 0.76 365 0.00 0
2009 PA GEN ENERGY CO LLC 3,877.44 365 0.00 0 0.00 0
2010 PA GEN ENERGY CO LLC 7,268.75 365 0.00 0 0.00 0
2011 PA GEN ENERGY CO LLC 3,239.00 365 0.00 0 0.00 0
2012 PA GEN ENERGY CO LLC 3,202.75 365 0.00 0 0.00 0
2013 PA GEN ENERGY CO LLC 6,981.33 365 0.00 0 0.00 0
2014 PA GEN ENERGY CO LLC 6,189.00 365 0.00 0 0.00 0
2015 0.00 0 0.00 0 0.00 0
2016 0.00 0 0.00 0 0.00 0
2017 0.00 0 0.00 0 0.00 0
2018 0.00 0 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2010-A00 Drilling Fluid Waste (in Barrels) 100.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010-A00 Drilling Fluid Waste (in Barrels) 200.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2010-A00 Produced Fluid (in Barrels) 101.75 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010-A00 Produced Fluid (in Barrels) 233.75 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011-A00 Drilling Fluid Waste (in Barrels) 15.48 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011-A00 Produced Fluid (in Barrels) 80.95 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2012-A00 Drilling Fluid Waste (in Barrels) 473.25 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2012-A00 Produced Fluid (in Barrels) 238.45 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2013-A00 Produced Fluid (in Barrels) 288.76 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0101508
2013-A00 Produced Fluid (in Barrels) 33.33 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0102784
2013-A00 Servicing Fluid (in Barrels) 33.33 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0101508
2014-A00 Produced Fluid (in Barrels) 164.05 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0101508
2014-A00 Produced Fluid (in Barrels) 126.67 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0102784

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2155314 Primary Facility 2013-04-10 Routine/Partial Inspection No Violations Noted
2423921 Primary Facility 2015-10-27 Routine/Complete Inspection No Violations Noted
2609269 Primary Facility 2017-06-12 Routine/Complete Inspection No Violations Noted
2648864 Primary Facility 2017-10-17 Routine/Complete Inspection No Violations Noted On 10/17/17 at 1310 hrs I conducted an inspection of the Warrant 3914 1906 well site. No one was present at the site. It was sunny and 57 degrees F.

The well was drilled by the Pennsylvania General Energy Co. (PGE) in 2006 and transferred to the Minard Run Oil Company on 3/23/17. The well was tagged. According to DEP records, the well was in production between 2008 - 2014; it has been on inactive status since 12/23/15.

The site is restored and permanently stabilized as per 25 Pa Code Section 102.22(a). A Well Site Restoration Report (WSRR) was received on 11/6/13 and acknowledged on 11/15/13.

No violations were cited during the inspection. I departed the location at 1345 hrs. TLT

2685854 Primary Facility 2018-01-23 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was not in production. The wellhead assembly all fittings and flow lines were tested for gas. The results of this testing was no gas was detected on the wellhead assembly or the well area.

For data sources see[6]

References