37-111-20304

Well Details

Well ID: 37-111-20304
Loading map...
Country: United States
State: Pennsylvania
County: Somerset
Municipality: Addison Township
Operator Name: LPR ENERGY LLC
Well Pad ID: 149073
Farm/Lease Name: PMG GRACE UNIT 1H
License Status: Active
Spud Date: 2011-06-11
Permit Date: 2011-05-31
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 39.757744
Longitude: -79.356553

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-04-30 2013-05-03 9304 4,814,130.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Unislik ST 50 CESI Friction Reducer Hydrotreated Light Distillite 64742-47-8 30 0.03182 0
Iron Control A Nalco Iron Control Ethylene Glycol 107-21-1 30 0.00709 0
ASP 900 Nalco Friction Reducer Ammonium Sulfate 7783-20-2 30
15% Hcl Acid Reagent/PPG Used to open perfs Hydrochloric Acid 7647-01-0 15 0.09599 0
GBL Clearwater Gel Breaker Ethylene Glycol 107-21-1 60 0.00004000 0
EC 6116a Nalco Biocide Polyethylene Glycol 25322-68-3 60 0.0153 0
Dibromoacetonitrile 3252-43-5 5 0.00127 0
1, 1-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.00765 0
Proppant Chevron Applachia, LLC Proppant Crystalline Sillica 14808-60-7 100 9.17 0
CMHPG Ashland Water Viscosifier Carboxymethyl Hydroxporoyl Guar Blend 68130-15-4 100 0.00234 0
Clean Volume Chevron Applachia, LLC Carrier/Base Fluid H20 7732-18-5 100 90.83 0
Scale Inhibitor A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00756 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 387,685.00 177 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 495,164.00 365 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 288,630.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 186,121.06 360 0.00 0 0.00 0
2017 LPR ENERGY LLC 151,718.00 363 0.00 0 0.00 0
2018 LPR ENERGY LLC 214,176.00 361 0.00 0 0.00 0
2019 LPR ENERGY LLC 72,714.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2011-S01 Drilling Fluid Waste (in Barrels) 220.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2011-S02 Drill Cuttings (in Tons) 781.73 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 101674
2011-S02 Fracing Fluid Waste (in Barrels) 190.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2011-S02 Produced Fluid (in Barrels) 410.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2012-S01 Drilling Fluid Waste (in Barrels) 240.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S01 Fracing Fluid Waste (in Barrels) 1,183.30 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013-S01 Fracing Fluid Waste (in Barrels) 108.60 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Fracing Fluid Waste (in Barrels) 7,584.60 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013-S02 Fracing Fluid Waste (in Barrels) 538.50 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Produced Fluid (in Barrels) 4,995.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S01 Fracturing Fluid Waste (in Tons) 33.56 Tons LANDFILL 100280
2014-S01 Produced Fluid (in Barrels) 3,346.67 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S02 Produced Fluid (in Barrels) 26.67 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014-S02 Produced Fluid (in Barrels) 1,464.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Produced Fluid (in Barrels) 525.67 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Produced Fluid (in Barrels) 539.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M04 Produced Fluid (in Barrels) RWC 802 35.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016-M05 Produced Fluid (in Barrels) RWC 802 29.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016-M07 Produced Fluid (in Barrels) RWC 802 44.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016-M08 Produced Fluid (in Barrels) RWC 802 42.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016-M09 Produced Fluid (in Barrels) RWC 802 120.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2016-M11 Produced Fluid (in Barrels) RWC 802 21.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016-M12 Produced Fluid (in Barrels) RWC 802 42.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016-S01 Produced Fluid (in Barrels) RWC 802 325.67 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M01 Produced Fluid (in Barrels) RWC 802 22.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-M02 Produced Fluid (in Barrels) RWC 802 53.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-M03 Produced Fluid (in Barrels) RWC 802 130.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM
2017-M04 Produced Fluid (in Barrels) RWC 802 64.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM
2017-M05 Produced Fluid (in Barrels) RWC 802 21.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM
2017-M06 Produced Fluid (in Barrels) RWC 802 22.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM
2017-M09 Produced Fluid (in Barrels) RWC 802 45.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2017-M10 Produced Fluid (in Barrels) RWC 802 15.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2018-M03 Produced Fluid (in Barrels) RWC 802 61.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM
2018-M04 Produced Fluid (in Barrels) RWC 802 106.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM
2018-M05 Produced Fluid (in Barrels) RWC 802 15.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM
2018-M06 Produced Fluid (in Barrels) RWC 802 57.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM
2018-M09 Produced Fluid (in Barrels) RWC 802 74.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM
2018-M10 Produced Fluid (in Barrels) RWC 802 49.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM
2018-M10 Produced Fluid (in Barrels) RWC 802 249.00 Bbl REUSE (AT WELL PAD)
2018-M11 Produced Fluid (in Barrels) RWC 802 25.00 Bbl REUSE (AT WELL PAD)
2018-M12 Produced Fluid (in Barrels) RWC 802 60.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM
2019-M01 Produced Fluid (in Barrels) RWC 802 60.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM
2019-M02 Produced Fluid (in Barrels) RWC 802 60.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM
2019-M03 Produced Fluid (in Barrels) RWC 802 40.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1985992 Primary Facility 2011-06-28 Drilling/Alteration No Violations Noted At the time of inspection, no E&S or IW discharge issues at the site. Chief contracted UDI. 9 5/8¿ pipe set at 3800 feet with Universal performed cement using gas block. Chevron present performing site inspection. Deviation of hole is less than 1 %. DEP performed a site walk and did not find any issues.
1986652 Primary Facility 2011-06-30 Routine/Complete Inspection No Violations Noted Site visit was part of routine inspection. Spoke with Bill Delcambre, Chief Company Man on site.
1997544 Primary Facility 2011-08-04 Routine/Complete Inspection No Violations Noted Site visit was part of routine inspection. Paule Wyrwas was present during inspection. Spoke with Tim Trib, Chief Company Man on site.
2003200 Primary Facility 2011-09-08 Routine/Complete Inspection No Violations Noted At the time of inspection, Well ID Sign, ES plan, and ESCGP-1 present. Access road entrance and roadway appear adequately rocked and stable. Well drilled and actively being vented while onsite, not yet in production. Temporary BMPs installed according to plan (both 12in and 18in compost soxs) and functioning. Noted ¿stressed¿ vegetation alongside and surrounding sediment traps. It appears as possible evidence that sediment traps are not properly functioning and/or water is improperly draining to traps. Although no (active) accelerated erosion or sedimentation issues are noted during this inspection, due to recent heavy rains, it is recommend that operator examine and monitor sediment traps and areas surrounding to ensure that proper drainage is occurring in order to prevent a possible pollution event. Noted red staining at toe slope of pad, again previously attributed to decomposition of mulch/tress. Accompanied by WQS Marc Maestra during inspection.
2016742 Primary Facility 2011-11-03 Routine/Complete Inspection No Violations Noted At the time of inspection, well sign (multi- well pad), ES Plan, ESCGP-1, PPC Plan present. Site gated and locked, as well as monitored by security. Access road and well pad adequately rocked and maintained. Well drilled. Well head protected from third party access with metal fencing. No accelerated erosion or sedimentation issues noted during inspection. Bmp's are installed and appear to be functioning, although operator should continue to monitor and maintain all bmp's until final permanent restoration is complete. Previously disturbed areas have been temporarily seeded/mulched with observed growth. No violations noted during this inspection.
2051548 Primary Facility 2012-03-14 Routine/Complete Inspection No Violations Noted Site visit was part of routine inspection.
2067333 Primary Facility 2012-05-04 Drilling/Alteration No Violations Noted At the time of inspection, no E&S issues were present at the site. Well head was modified in order to drill gas well Grace 2H.
2069203 Primary Facility 2012-05-10 Routine/Complete Inspection No Violations Noted At the time of inspection the site appeared to be in sound condition. The E&S plan was onsite and properly installed and maintained. The Department notes that a significant precipitation event occurred in the past 24 hours and the site shows no accelerated erosion on the well pad area or the access road.
2069224 Primary Facility 2012-05-18 Routine/Complete Inspection No Violations Noted At the time of inspection the site appeared to be in sound condition. The E&S plan was onsite and properly installed and maintained.
2078296 Primary Facility 2012-06-20 Routine/Complete Inspection No Violations Noted At the time of this inspection, well sign ES plan, PPC plan, ESCGP-1 onsite. Site gated by 24hr security. Well(s) drilled. Bmp's installed and functioning according to Es plan. No accelerated erosion or sedimentation issues noted with site or access road. No industrial waste issues present. Operator plans to drill 4H in the near future. One roll off box located onsite. ROC Rep Blair onsite during inspection.
2094686 Primary Facility 2012-08-06 Drilling/Alteration No Violations Noted At the time of inspection, no E&S issues were present at the site. Crown rig 8 was set up on well 2H to drill the curve and horizontal section.
2094814 Primary Facility 2012-08-14 Drilling/Alteration No Violations Noted At the time of inspection, no E&S issues were present at the site. Crown rig 8 was set up on well 2H to drill the curve and horizontal section.
2095539 Primary Facility 2012-08-28 Drilling/Alteration No Violations Noted At the time of inspection, no E&S issues were present at the site. Crown rig 8 was set up on well 3H to drill the curve and horizontal section.
2107614 Primary Facility 2012-10-09 Site Restoration No Violations Noted At the time of inspection the well appeared to be drilled but not equipped for production. The Erosion and Sedimentation plan was onsite and appeared to installed as outlined in the plan. No observation of accelerated erosion or sedimentation in relation to the well pad area or access road. The Department suggest the Operator continue to monitor the site weekly and after significant precipitation event to ensure the stability of the site is maintained.
2123137 Primary Facility 2012-12-12 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S issues were present at the site. Gas well was not in production
2144612 Primary Facility 2013-02-25 Routine/Complete Inspection No Violations Noted Multi-well pad. Site ID sign, valid permit, E&S plan, ESCGPI, PPC plan all on-site.
2160659 Primary Facility 2013-04-23 Incident- Response to Accident or Event No Violations Noted Incident inspection. Company reported a 10 gallon spill. Company could not find spill location. Asked company to locate spill.
2163938 Primary Facility 2013-05-02 Follow-up Inspection No Violations Noted Follow up inspection to a 4/21/13 spill. Spill Cleaned up correctely.
2169703 Primary Facility 2013-05-22 Routine/Complete Inspection No Violations Noted
2182694 Primary Facility 2013-07-11 Routine/Complete Inspection No Violations Noted Met with chevron on site. No issues noted.
2229820 Primary Facility 2013-09-26 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S issues were present at the site. Well was in production.
2297854 Primary Facility 2014-08-20 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S issues were present at the site. Well was in production
2311292 Primary Facility 2014-10-08 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2408926 Primary Facility 2015-09-18 Routine/Complete Inspection No Violations Noted At time of inspection, well tag present and legible.
2486270 Primary Facility 2016-05-19 Routine/Complete Inspection No Violations Noted system running. no issues
2532260 Primary Facility 2016-10-05 Routine/Complete Inspection No Violations Noted no issues, system running.
2548876 Primary Facility 2016-12-29 Routine/Complete Inspection No Violations Noted Multi-well Marcellus pad.

Site ID sign, E&S plan, ERP and PPC plan on site. At time of inspection no E&S issues observed on access road. Well pad surrounded by security fence. Well pad rocked, no E&S issues observed. Well appears equipped for production. Well tag present and legible. Brine tank located in secondary containment appears structurally sound.

2594473 Primary Facility 2017-04-25 Routine/Complete Inspection No Violations Noted system running. no issues
2594597 Primary Facility 2017-05-16 Routine/Complete Inspection No Violations Noted system running. no issues
2626062 Primary Facility 2017-08-16 Routine/Complete Inspection No Violations Noted system running. no issues
2656086 Primary Facility 2017-11-02 Routine/Complete Inspection No Violations Noted Site sign present. Three wells present at site. All wells active. Site gated and locked. No,issues at the site
2672005 Primary Facility 2017-12-18 Routine/Complete Inspection No Violations Noted System producing. No issues
2672095 Primary Facility 2017-12-18 Routine/Complete Inspection No Violations Noted Well appears to be in production. Well head surrounded by cement barriers. Site gated.
2685325 Primary Facility 2018-01-23 Routine/Complete Inspection No Violations Noted System producing. Emergency contact present. Well tag present.
2700688 Primary Facility 2018-03-05 Routine/Complete Inspection No Violations Noted Multi well site. Well appears to be in production. Three brine tanks on site. Well pad surrounded by security fence. Well head surrounded by cement barriers.
2700699 Primary Facility 2018-03-05 Routine/Complete Inspection No Violations Noted Well tag present and emergency contact information present. No issues at the site
2766556 Primary Facility 2018-08-23 Routine/Complete Inspection No Violations Noted Well appears equipped for production. Well pad surrounded by security fence. Well head surrounded by cement barriers. Three brine tanks on site.

For data sources see[7]

References