37-115-21223

Well Details

Well ID: 37-115-21223
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Harford Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 146436
Farm/Lease Name: PRITCHARD D 1
License Status: Active
Spud Date: 2013-06-27
Permit Date: 2013-04-09
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.798317
Longitude: -75.704883

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-10-11 2013-10-22 6953 13,723,700.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Plexbreak 145 Chemplex Non-Emulsifier Methyl Alcohol 67-56-1 15 0.000140074 182.655
2-Butoxyethanol 111-76-2 15 0.000140074 182.655
Diethanolamine 111-42-2 3 0.00002801 36.531
Cocamide Based Surfactant Proprietary 10 0.00009338 121.77
Water Rain for Rent Carrier/Base Fluid Water 7732-18-5 100 88.316 115,163,000.0
Plexhib 256 Chemplex Acid Inhibitor Polyethoxylated Alcohol Surfactant 68951-67-7 30 0.000250966 327.258
Thiourea/Formaldehyde Copolymer 68527-49-1 30 0.000250966 327.258
Propargyl Alcohol 107-19-7 10 0.00008366 109.086
Methyl Alcohol 67-56-1 60 0.000501933 654.515
C-14 to C-16 Alpha Olefins 64743-02-8 5 0.00004183 54.543
Hydrochloric Acid (15%) Reagent Acidizing Hydrochloric Acid 7647-01-0 15 0.0787525 102692
Plexslick 957 Chemplex Friction Reducer Paraffinic, Naphtehenic Solvent 64742-47-8 30 0.0191068 24915
Poly (acrylamide-co-acrylic acid), partial sodium salt 62649-23-4 35 0.0222912 29067.5
Nonionic Surfactants Proprietary 1.5 0.000955338 1245.75
Ammonium Chloride 12125-02-9 5 0.00318446 4152.5
Ferriplex 40 Chemplex Iron Control Sodium Hydroxide 1310-73-2 1 0.00002845 37.102
Sodium Sulfate Anhydrous 7757-82-6 2 0.00005691 74.204
Trisodium Nitrilotriacetate 5064-31-3 40 0.0011381 1484.08
Plexcide 15G Chemplex Biocide Ethanol 64-17-5 3 0 887.178
Glutaraldehyde 111-30-8 14 0.003175 4140.16
Alkyl Dimethyl Benzyl Ammonium Chloride 68424-85-1 3 0 887.178
Didecyl Dimethyl Ammonium Chloride 7173-51-5 3 0.000680357 887.178
Sand (Proppant) TSS Proppant Silica Substrate 14808-60-7 100 11.0437 14,400,800.0
Greenhib 679 Chemplex Friction Reducer Glycerine 56-81-5 20 0.00487537 6357.42
Proprietary Proprietary 35 0.00853189 11125.5

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 CABOT OIL & GAS CORP 727,469.93 48 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 4,158,172.65 362 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 2,033,711.12 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 1,623,790.66 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 1,192,843.30 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 1,040,455.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 244,757.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2013-S02 Drill Cuttings (in Tons) 1,012.72 Tons LANDFILL 101247
2013-S02 Drill Cuttings (in Tons) 297.12 Tons LANDFILL THR029
2013-S02 Drilling Fluid Waste (in Barrels) 118.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2013-S02 Drilling Fluid Waste (in Barrels) 225.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013-S02 Fracing Fluid Waste (in Barrels) 1,539.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2013-S02 Fracing Fluid Waste (in Barrels) 3,740.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013-S02 Produced Fluid (in Barrels) 20,296.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014-S01 Produced Fluid (in Barrels) 111.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014-S01 Produced Fluid (in Barrels) 6,487.31 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014-S02 Produced Fluid (in Barrels) 7.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014-S02 Produced Fluid (in Barrels) 2,461.02 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015-S01 Produced Fluid (in Barrels) 5.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2015-S01 Produced Fluid (in Barrels) 1,749.38 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015-S02 Produced Fluid (in Barrels) 1,298.80 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016-S01 Produced Fluid (in Barrels) RWC 802 968.51 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016-S02 Produced Fluid (in Barrels) RWC 802 56.45 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE004
2016-S02 Produced Fluid (in Barrels) RWC 802 855.54 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017-M01 Produced Fluid (in Barrels) RWC 802 184.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017-M02 Produced Fluid (in Barrels) RWC 802 159.84 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017-M03 Produced Fluid (in Barrels) RWC 802 81.37 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017-M03 Produced Fluid (in Barrels) RWC 802 61.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017-M04 Produced Fluid (in Barrels) RWC 802 89.37 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017-M04 Produced Fluid (in Barrels) RWC 802 47.88 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017-M05 Produced Fluid (in Barrels) RWC 802 131.12 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017-M06 Produced Fluid (in Barrels) RWC 802 115.34 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017-M06 Produced Fluid (in Barrels) RWC 802 53.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017-M07 Produced Fluid (in Barrels) RWC 802 55.68 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017-M07 Produced Fluid (in Barrels) RWC 802 106.30 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017-M08 Produced Fluid (in Barrels) RWC 802 126.81 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017-M09 Produced Fluid (in Barrels) RWC 802 97.82 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017-M10 Produced Fluid (in Barrels) RWC 802 176.44 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017-M11 Produced Fluid (in Barrels) RWC 802 128.63 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017-M12 Produced Fluid (in Barrels) RWC 802 97.49 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018-M01 Produced Fluid (in Barrels) RWC 802 73.91 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018-M01 Produced Fluid (in Barrels) RWC 802 40.23 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-M02 Produced Fluid (in Barrels) RWC 802 71.06 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-M02 Produced Fluid (in Barrels) RWC 802 46.21 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2018-M03 Produced Fluid (in Barrels) RWC 802 10.55 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018-M03 Produced Fluid (in Barrels) RWC 802 129.70 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-M04 Produced Fluid (in Barrels) RWC 802 147.91 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018-M05 Produced Fluid (in Barrels) RWC 802 105.65 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018-M06 Produced Fluid (in Barrels) RWC 802 65.96 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018-M06 Produced Fluid (in Barrels) RWC 802 42.22 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-M07 Produced Fluid (in Barrels) RWC 802 108.93 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018-M07 Produced Fluid (in Barrels) RWC 802 50.27 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-M08 Produced Fluid (in Barrels) RWC 802 117.95 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-M09 Produced Fluid (in Barrels) RWC 802 157.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-M10 Produced Fluid (in Barrels) RWC 802 156.39 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-M11 Produced Fluid (in Barrels) RWC 802 132.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-M12 Produced Fluid (in Barrels) RWC 802 145.55 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019-M01 Produced Fluid (in Barrels) RWC 802 109.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2019-M02 Produced Fluid (in Barrels) RWC 802 48.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019-M02 Produced Fluid (in Barrels) RWC 802 108.49 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2019-M03 Produced Fluid (in Barrels) RWC 802 114.21 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2179928 Primary Facility 2013-07-02 Drilling/Alteration No Violations Noted Spudder rig on location
2180030 Primary Facility 2013-06-25 Routine/Complete Inspection No Violations Noted The Department was on site at the D Pritchard Well Site to conduct a Preoperational Inspection. Well permits that have been issued for this pad are the 1H (115-21223), 2H (115-21224), and the 3H (115-21225). Inspection conducted with Eric Griffin of Don Bower Construction and Dillon Otten field tech for Tioga Environmental Consulting. All perimeter BMP’s in place. Red lined diversion berm reconfiguration located on the northeast side of the pad is acceptable. Pad is approximately 80% complete.
2231985 Primary Facility 2013-12-11 Routine/Complete Inspection No Violations Noted Inspection conducted on 12/11/13. Inspection conducted in response to a complaint that pad design and installation is causing increased storm water flow to agricultural field. Ground is frozen and snow covered. Pad placement does not appear as if would increase storm water flow to field in question.
2238465 Primary Facility 2014-01-23 Administrative/File Review Pending On 1/21/14, Andy Mehalko reported the following incident: On 1/20/14 at approximately 10:00 AM a release of approximately 5-6 gallons of glycol solution was identified at the Pritchard 1H well. Due to an issue with the thermostat on the GPU, the burner unit overheated the glycol solution causing it to flow, as designed, into the adjacent overflow tank. At this point, due to the volume and temperature of the fluid transferred, it escaped the primary overflow tank and was captured by the secondary containment system consisting of an overpack type drum. Unfortunately, the drain valve at the bottom of the overpack drum was not fully seated allowing a portion of the fluid to migrate to the pad surface.
2262826 Primary Facility 2014-04-16 Administrative/File Review Viol(s) Noted & Immediately Corrected This administrative inspection has been created to document Cabot’s remediation of the small spill which occurred on their Pritchard, D. Pad documented in the 1/23/14 inspection record # 2238465. A review of the remediation summary report prepared by Resource Environmental indicates that the remediation was adequate. No further action is required of Cabot at this time. Attached is a copy of the remediation summary report, the waste manifest associated with this spill, and the 1/23/14 inspection.
2476528 Primary Facility 2016-04-20 Routine/Complete Inspection No Violations Noted
2486951 Primary Facility 2016-05-23 Routine/Complete Inspection No Violations Noted
2502677 Primary Facility 2016-07-18 Routine/Complete Inspection No Violations Noted
2510521 Primary Facility 2016-08-11 Routine/Partial Inspection No Violations Noted
2533885 Primary Facility 2016-11-01 Routine/Complete Inspection No Violations Noted On 11/1/16, the Department conducted an inspection of the COG Pritchard D Well Site located in Harford Township, Susquehanna County in response to a nearby malodor complaint. The Department arrived on-site at approximately 12:00 AM. There are 2 wells drilled and in production on this pad, the 1H and 2H. The pad is equipped with the standard equipment associated with steady state production. A water truck was collecting produced fluid from the production tanks during the inspection. No other activity is occurring at this pad. I spent approximately 5 minutes at each corner of the well pad and did not detect any malodors. No E&S issues were observed during this inspection. No violations noted.
2582540 Primary Facility 2017-04-12 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 14:20p.m.

The cellar was about a quarter full of water with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into the production tank, the (9x5) annulus vent pipe was open and venting into the production tank. There was 498psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:45p.m.

2688197 Primary Facility 2018-01-30 Routine/Complete Inspection No Violations Noted At time of inspection.

The cellar had water about 6.5' below grade and there was no bubbling noticed. The (20x13) annulus was above the water level and there was no gas detected. The (13x9) and (9x5) annuli vent pipes were connected together and venting to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2737674 Primary Facility 2018-06-04 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. No E&S issues identified. No violations noted.
2786347 Primary Facility 2018-10-10 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 6.5' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same production tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2834854 Primary Facility 2019-01-31 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. As the photo's show, the site is snow covered. Production tank containment should be emptied the next time the stormwater melts, as there is not much free board present. Overall the site has good stabilization. No E&S issues identified. No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2262826 693345 04/16/2014 2014-04-16 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety

For data sources see[7]

References