{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.996642,"lon":-75.715489,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Great Bend Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 152982 | |
Farm/Lease Name: DAYTON 4H | |
License Status: Active | |
Spud Date: 2014-05-05 | |
Permit Date: 2014-01-16 | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Latitude: 41.996642 | |
Longitude: -75.715489 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-09-23 | 2015-09-29 | 5763 | 5,044,020.0 | 46780 |
2 | 2014-09-19 | 2014-09-21 | 5734 | 1,714,570.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | HYDROCHLORIC ACID | Halliburton | Base Fluid | NA | NA | 0 | 0 | 0 |
Fresh Water | Operator | Base Fluid | Fresh Water | 7732-18-5 | 100 | 81.7614 | 42,722,700.0 | |
Hazardous and Non-Hazardous Ingredients | Tributyl tetradecyl phosphonium chloride | 81741-28-8 | 10 | 0.00193004 | 1009 | |||
Water | 7732-18-5 | 100 | 0.871397 | 455332 | ||||
Crystalline silica, quartz | 14808-60-7 | 100 | 17.3089 | 9,044,400.0 | ||||
Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.0249727 | 13049 | ||||
Acrylamide acrylate polymer | Confidential | 30 | 0.0249727 | 13049 | ||||
Hydrochloric acid | 7647-01-0 | 15 | 0.120323 | 62872 | ||||
Ammonium Chloride | 12125-02-9 | 30 | 0.00743778 | 3887 | ||||
Organic phosphonate | Proprietary | 60 | 0.0148756 | 7773 | ||||
Sodium chloride | 7647-14-5 | 30 | 0.0249727 | 13049 | ||||
Non-hazardous food substance | Proprietary | 100 | 0.000268578 | 141 | ||||
BE-9, FR-76, HAI-150E, LP-65 MC, SAND-COMMON WHITE - 100 MESH, SAND-PREMIUM WHITE-30/50 |
Halliburton | Biocide, Corrosion Inhibitor, Friction Reducer, Proppant, Scale Inhibitor | NA | NA | 0 | 0 | 0 | |
2 | EC6486 | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.00306584 | 521.028 |
Water | SWN | Water / Produced Water | H2O + Disolved Salts | 7732-18-5 | 100 | 84.1916 | 14,308,100.0 | |
FRA-405 | Clearwater | Friction Reducer | Sodium Chloride | 7647-14-5 | 10 | 0.00655829 | 1114.56 | |
Ammonium Chloride | 12125-02-9 | 7 | 0.00459081 | 780.191 | ||||
Alcohols, C-12-16, Ethoxylated | 68551-12-2 | 7 | 0.00459081 | 780.191 | ||||
Petroleum Distillates | 64742-47-8 | 40 | 0.0262332 | 4458.23 | ||||
Sand | Keane | Sand | Crystalline Silica, Quartz | 14808-60-7 | 100 | 14.5252 | 2,468,500.0 | |
AI-600 | Weatherford | Acid Inhibitor | Cinnamaldehyde | 104-55-2 | 10 | 0.000298236 | 50.684 | |
Tar bases, quinoline derivs, benzyl chloride-quaternized | 72480-70-7 | 13 | 0.000387707 | 65.889 | ||||
Ethoxylated Nonylphenol | 68412-54-4 | 10 | 0.000298236 | 50.684 | ||||
N,N-Dimethylformamide | 68-12-2 | 40 | 0.00119294 | 202.736 | ||||
Ethylene Glycol | 107-21-1 | 60 | 0.00178941 | 304.105 | ||||
Isopropyl Alchol | 67-63-0 | 7 | 0.000208765 | 35.479 | ||||
2-Butoxyethanol | 111-76-2 | 7 | 0.000208765 | 35.479 | ||||
Triethyl Phosphate | 78-40-0 | 7 | 0.000208765 | 35.479 | ||||
15% HCl | Reagent | Acid | HCL | 7647-01-0 | 15 | 0.178941 | 30410.5 | |
K Bac -1020 | WST | Biocide | 2,2-Diobrom-3nirilopropionamide | 10222-01-2 | 20 | 0.0023012 | 391.08 | |
Polyethylene glycol | 25322-68-3 | 60 | 0.00690359 | 1173.24 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | SOUTHWESTERN ENERGY PROD CO | 347,827.00 | 83 | 0.00 | 0 | 0.00 | 0 |
2016 | SWN PROD CO LLC | 1,027,770.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | SWN PROD CO LLC | 665,388.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2018 | SWN PROD CO LLC | 513,834.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 30,942.00 | 48 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2014-S01 | Drill Cuttings (in Tons) | 835.78 Tons | LANDFILL | 101247 |
2014-S01 | Drilling Fluid Waste (in Barrels) | 880.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2014-S02 | Drill Cuttings (in Tons) | 608.14 Tons | LANDFILL | 101247 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 5,986.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S02 | Fracturing Fluid Waste (in Tons) | 10.74 Tons | LANDFILL | THR029 |
2015-S02 | Fracing Fluid Waste (in Barrels) | 90.00 Bbl | LANDFILL | THR029 |
2015-S02 | Fracing Fluid Waste (in Barrels) | 6,180.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Produced Fluid (in Barrels) | 33,978.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M01 | Produced Fluid (in Barrels) RWC 802 | 4,061.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M02 | Produced Fluid (in Barrels) RWC 802 | 2,069.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M03 | Produced Fluid (in Barrels) RWC 802 | 2,057.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M04 | Produced Fluid (in Barrels) RWC 802 | 1,651.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M05 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 115.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M05 | Produced Fluid (in Barrels) RWC 802 | 1,497.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M06 | Produced Fluid (in Barrels) RWC 802 | 1,342.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M07 | Produced Fluid (in Barrels) RWC 802 | 1,243.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M08 | Produced Fluid (in Barrels) RWC 802 | 1,128.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M09 | Produced Fluid (in Barrels) RWC 802 | 405.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M09 | Synthetic Liner Materials (in Tons) RWC 806 | 3.66 Tons | LANDFILL | 101247 |
2016-M10 | Produced Fluid (in Barrels) RWC 802 | 395.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M11 | Produced Fluid (in Barrels) RWC 802 | 325.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M12 | Produced Fluid (in Barrels) RWC 802 | 375.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 759.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 681.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 686.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M10 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 0.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 224.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M11 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 23.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 184.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 219.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M01 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 40.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 1,306.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 661.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 218.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 330.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 661.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 206.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 334.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 334.00 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 1,765.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 771.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M07 | Synthetic Liner Materials (in Tons) RWC 806 | 6.00 Tons | LANDFILL | 100933 |
2018-M08 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 115.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 114.00 Bbl | REUSE (AT WELL PAD) | |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 551.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 440.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 330.00 Bbl | REUSE (AT WELL PAD) | |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 220.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 440.00 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M12 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 110.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 340.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 120.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 1,180.00 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 28,300.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019-M02 | Unused Fracturing Fluid Waste (in Tons) RWC 805 | 12.43 Tons | LANDFILL | 100933 |
2019-M02 | Unused Fracturing Fluid Waste (in Tons) RWC 805 | 15.15 Tons | LANDFILL | 101247 |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 40,221.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2268118 | Primary Facility | 2014-04-29 | Preoperation Inspection | No Violations Noted | The Department was on site at the SWN NR11 Well Site to conduct a Preoperational Inspection. Inspection was conducted with Rich Gulyas and Andy Breese. The well permit issued for this pad is the Dayton Pad (115-21607). All perimeter BMPs are in place including red lined additions. Pad is 90% complete. Culvert C-7 inlet slightly compressed due to heavy truck traffic in area but is currently being repaired. No violations noted. |
2284363 | Primary Facility | 2014-06-27 | Routine/Complete Inspection | No Violations Noted | Precision 532, well shut in. Liner on location. Well not fract. No visible bubbling in cellar. No gauges on annuli |
2301713 | Primary Facility | 2014-09-06 | Drilling/Alteration | No Violations Noted | |
2357370 | Primary Facility | 2015-04-01 | Routine/Complete Inspection | No Violations Noted | |
2382339 | Primary Facility | 2015-06-25 | Routine/Complete Inspection | No Violations Noted | |
2406054 | Primary Facility | 2015-09-10 | Drilling/Alteration | No Violations Noted | |
2407177 | Primary Facility | 2015-09-15 | Routine/Complete Inspection | No Violations Noted | |
2422123 | Primary Facility | 2015-11-03 | Routine/Complete Inspection | No Violations Noted | |
2433921 | Primary Facility | 2015-12-17 | Routine/Complete Inspection | No Violations Noted | |
2437089 | Primary Facility | 2015-12-30 | Routine/Complete Inspection | No Violations Noted | |
2451204 | Primary Facility | 2016-02-19 | Routine/Complete Inspection | No Violations Noted | |
2465610 | Primary Facility | 2016-03-17 | Routine/Complete Inspection | No Violations Noted | |
2474808 | Primary Facility | 2016-04-14 | Routine/Complete Inspection | No Violations Noted | |
2480212 | Primary Facility | 2016-04-25 | Routine/Complete Inspection | No Violations Noted | On 4/25/16, the Department conducted a routine inspection of the SWN NR 11 Dayton Pad. The Department observed good temporary stabilization. Vegetation is well established. Only one of the 3 wells that have been drilled on this pad has been stimulated and placed into production, the Dayton 4H, 115-21607. The 5H, 115-22069 and the 6H, 115-22070 have been drilled only. Temporary containment is still in place around the well heads. A cage has been placed around the 4H. The pipeline tie-in has good temporary stabilization. No violations noted. |
2484770 | Primary Facility | 2016-05-17 | Routine/Complete Inspection | No Violations Noted | |
2495501 | Primary Facility | 2016-06-23 | Routine/Complete Inspection | No Violations Noted | |
2569507 | Primary Facility | 2017-03-06 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 12:00p.m.
There was containment around the well that made for limited access to the cellar. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge and a 1000psi pressure gauge with 0psi on it, the valve going to the production tank was closed. There was 561psi on the production casing and 322psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 12:30p.m. |
2665131 | Primary Facility | 2017-11-29 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was containment around the well and was unable check the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2679185 | Primary Facility | 2018-01-05 | Site Restoration | No Violations Noted | I inspected the Northwest Unit 11 well pad for Notice of Termination (NOT) inspection. The pad has 1 active well on site, the 4h, permit #115-21607. There are two wells, the 5h and 6h which are in Regulatory Inactive status. Their permit #s are 115-22069 and 115-22070, respectively. The site was overall in good shape with no erosional issues present at the time of inspection. The vegetation which was appearing through the snow cover appeared full. The wells(s) were properly labeled.
There were no violations observed. I recommend APPROVAL of this NOT. |
2766100 | Primary Facility | 2018-08-22 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was containment around the well but I was able to notice the cellar was set up with a plastic corrugated pipe around the well for inspection access. There was water .5' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2793254 | Primary Facility | 2018-10-11 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted as a routine inspection. Entire site has good stabilization. No violations noted. |