If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-21995 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.861672,"lon":-75.714903,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: New Milford Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 152491 | |
Farm/Lease Name: TNT LIMITED PARTNERSHIP WEST 4H | |
License Status: Active | |
Spud Date: 2015-05-13 | |
Permit Date: 2015-04-23 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.861672 | |
Longitude: -75.714903 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2016-11-07 | 2016-11-11 | 6476 | 7,053,950.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Crystalline silica, quartz | 14808-60-7 | 100 | 13.9008 | 9,634,600.0 | |||
Non-hazardous food substance | Proprietary | 100 | 0.000119753 | 83 | ||||
Propylene glycol | 57-55-6 | 60 | 0.0236676 | 16404 | ||||
Diammonium phosphate | 7783-28-0 | 5 | 0.00115352 | 800 | ||||
Inorganic salt | Proprietary | 30 | 0.0256531 | 17781 | ||||
Tributyl tetradecyl phosphonium chloride | 81741-28-8 | 10 | 0.00394461 | 2734 | ||||
Organic phosphonate | Proprietary | 60 | 0.0138422 | 9594 | ||||
Ammonium chloride | 12125-02-9 | 30 | 0.00692112 | 4797 | ||||
Acrylamide acrylate copolymer | Proprietary | 30 | 0.0256531 | 17781 | ||||
Hydrochloric acid | 7647-01-0 | 15 | 0.17597 | 121695 | ||||
Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.0256531 | 17781 | ||||
LP-65 MC | Halliburton | Scale Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 | |
FR-76 | Halliburton | Friction Reducer | Listed Below | Listed Below | 0 | 0 | 0 | |
BE-9W | Halliburton | Biocide | Listed Below | Listed Below | 0 | 0 | 0 | |
Ingredients | Listed Above | Listed Above | Water | 7732-18-5 | 100 | 1.27773 | 885591 | |
SAND-COMMON WHITE-100 MESH | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 | |
HAI-150E | Halliburton | Corrosion Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 | |
HYDROCHLORIC ACID | Halliburton | Solvent | Listed Below | Listed Below | 0 | 0 | 0 | |
SAND-PREMIUM WHITE-30/50 | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 | |
Fresh Water | Operator | Base Fluid | Water | 7732-18-5 | 100 | 84.7779 | 58,759,200.0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2015 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | SWN PROD CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | SWN PROD CO LLC | 3,571,341.00 | 336 | 0.00 | 0 | 0.00 | 0 |
2018 | SWN PROD CO LLC | 1,393,140.00 | 348 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 292,518.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2015-S01 | Drilling Fluid Waste (in Barrels) | 934.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Drill Cuttings (in Tons) | 1,483.77 Tons | LANDFILL | 101247 |
2016-M08 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 18.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M12 | Fracturing Fluid Waste (in Barrels) RWC 805 | 6.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M12 | Fracturing Fluid Waste (in Tons) RWC 805 | 29.60 Tons | LANDFILL | THR029 |
2016-M12 | Produced Fluid (in Barrels) RWC 802 | 84.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M12 | Synthetic Liner Materials (in Tons) RWC 806 | 10.33 Tons | LANDFILL | 101247 |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 108.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M03 | Synthetic Liner Materials (in Tons) RWC 806 | 5.00 Tons | LANDFILL | THR029 |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 3,245.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 2,021.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 18.67 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 188.67 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 131.17 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M09 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 3.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 132.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 96.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M11 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 10.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 245.83 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 56.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 112.83 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M01 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 15.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 318.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 21.73 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 115.50 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 20.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 16.67 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 38.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 114.17 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 41.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 57.17 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 57.00 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 18.67 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 96.67 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M08 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 63.10 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 19.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 115.50 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 130.83 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 94.00 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 18.33 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 84.17 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 20.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019-M01 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 3.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 59.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 20.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019-M03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 18.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 59.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2370921 | Primary Facility | 2015-05-19 | Drilling/Alteration | No Violations Noted | |
2381035 | Primary Facility | 2015-06-22 | Drilling/Alteration | No Violations Noted | |
2386280 | Primary Facility | 2015-07-09 | Routine/Complete Inspection | No Violations Noted | |
2398079 | Primary Facility | 2015-08-13 | Drilling/Alteration | No Violations Noted | |
2403780 | Primary Facility | 2015-09-01 | Routine/Complete Inspection | No Violations Noted | |
2450200 | Primary Facility | 2016-02-16 | Routine/Complete Inspection | No Violations Noted | |
2471421 | Primary Facility | 2016-04-05 | Routine/Complete Inspection | No Violations Noted | |
2540483 | Primary Facility | 2016-11-23 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 12:45p.m., Halliburton was on site and fracking the wells. I met with company men Dave Wilcox and Jonathan Davidson. They were planning on shutting down for the holiday and continuing back up on Friday. They completed stage 10 out of 19 stages on the 1H and the 2H, 3H, 4H, and 5H were completed. There were 18 stages on the 2H, 21 stages on the 3H, 23 stages on the 4H and 5H. I took a walk around the location and there were no obvious concerns noticed.
I left the site at 13:20p.m. |
2568368 | Primary Facility | 2017-03-07 | Routine/Complete Inspection | No Violations Noted | The site was stable. The wells on this site have been recently flowed back and placed into production. |
2578039 | Primary Facility | 2017-03-30 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 10:30a.m.
The well was recently completed and is in production. The well tag was on the well and correct. The cellar was set up with a plastic corrugated pipe around the well for inspection access; there was water above the surface casing with no bubbling noticed. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge, the valve going to the production tank was closed. There was 775psi on the production casing. There was a crew on site cleaning out two 500bbl tanks that were on containment and the containment appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed. I left the site at 11:25a.m. |
2674620 | Primary Facility | 2017-12-14 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. The (20x13) and (13x9) annuli were below the water level and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2695797 | Primary Facility | 2018-02-14 | Routine/Complete Inspection | No Violations Noted | Inspection conducted as a routine inspection. No E&S issues were identified. No violations noted. |
2776470 | Primary Facility | 2018-09-18 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was containment around the five newest wells drilled and was unable to inspect the cellar. The well tender was on site when I arrived and he said tubing was recently put in the wells. The containment appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
For data sources see[7]