If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-117-21295 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.687692,"lon":-77.078933,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Blossburg Borough | |
Operator Name: SENECA RESOURCES CO LLC | |
Well Pad ID: 148214 | |
Farm/Lease Name: DCNR 595 PAD E 12H 50181 | |
License Status: Active | |
Spud Date: 2011-08-23 | |
Permit Date: 2011-07-22 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.687692 | |
Longitude: -77.078933 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-06-06 | 2012-06-06 | 7903.00 | 6,821,598.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Proppant 30/50 Ottawa | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 4.74 | |
Iron Stabilizer II | Universal Well Services | Corrosion Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00044000 | ||
ScaleHib 100 | Universal Well Services | Scale Inhibitor | Ethylene glycol | 107-21-1 | 60.00 | 0.00864000 | ||
GB L | Universal Well Services | Breaker | Ethylene glycol | 107-21-1 | 60.00 | 0.00 | ||
Unihib G | Universal Well Services | Corrosion Inhibitor | Ethoxylated Alcohol | 35.00 | 0.00013000 | |||
Diethylene glycol monobutyl ether | 112-34-5 | 50.00 | 0.00019000 | |||||
Resin Based Nonionic Inhibitor | 35.00 | 0.00013000 | ||||||
7.5 HydroChloric Acid | Universal Well Services | Acid | Hydrochloric acid | 7647-01-0 | 7.50 | 0.06 | ||
Proppant 40/70 Ottawa | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 4.83 | ||
Proppant 80/100 Oklahoma | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 0.22 | ||
Unislik ST 50 | Universal Well Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | ||
BioRid 20L | Tetra | Biocide | Sodium bromide | 7647-15-6 | 15.00 | 0.00205000 | ||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00273000 | |||||
Unigel 5F | Universal Well Services | Guar Gel Dry Add | Guar Gum | 100.00 | 0.00008000 | |||
15 HydroChloric Acid | Universal Well Services | Acid | Hydrochloric acid | 7647-01-0 | 15.00 | 0.00961000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SENECA RESOURCES CO LLC | 866,590.00 | 169 | 0.00 | 0 | 0.00 | 0 |
2013 | SENECA RESOURCES CO LLC | 1,456,534.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | SENECA RESOURCES CO LLC | 994,492.70 | 335 | 0.00 | 0 | 0.00 | 0 |
2015 | SENECA RESOURCES CO LLC | 347,275.78 | 88 | 0.00 | 0 | 0.00 | 0 |
2016 | SENECA RESOURCES CO LLC | 502,527.51 | 138 | 0.00 | 0 | 0.00 | 0 |
2017 | SENECA RESOURCES CO LLC | 830,511.65 | 359 | 0.00 | 0 | 0.00 | 0 |
2018 | SENECA RESOURCES CO LLC | 591,744.21 | 353 | 0.00 | 0 | 0.00 | 0 |
2019 | SENECA RESOURCES CO LLC | 129,238.40 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2011-S02 | Drill Cuttings (in Tons) | 739.85 Tons | LANDFILL | 301358 |
2012-S01 | Drill Cuttings (in Tons) | 527.59 Tons | LANDFILL | 301358 |
2012-S01 | Fracing Fluid Waste (in Barrels) | 102.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23584 |
2012-S01 | Fracing Fluid Waste (in Barrels) | 4,473.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-S02 | Drill Cuttings (in Tons) | 3.84 Tons | LANDFILL | 301358 |
2012-S02 | Fracturing Fluid Waste (in Tons) | 1.58 Tons | LANDFILL | 301358 |
2012-S02 | Produced Fluid (in Barrels) | 20.00 Bbl | INJECTION DISPOSAL WELL | 34-083-24072 |
2012-S02 | Produced Fluid (in Barrels) | 455.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20525 |
2012-S02 | Produced Fluid (in Barrels) | 60.00 Bbl | INJECTION DISPOSAL WELL | 34-151-23420 |
2012-S02 | Produced Fluid (in Barrels) | 907.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2012-S02 | Produced Fluid (in Barrels) | 887.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2012-S02 | Produced Fluid (in Barrels) | 132.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2012-S02 | Produced Fluid (in Barrels) | 133.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21894 |
2012-S02 | Produced Fluid (in Barrels) | 133.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23203 |
2012-S02 | Produced Fluid (in Barrels) | 238.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2012-S02 | Produced Fluid (in Barrels) | 10,648.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S01 | Produced Fluid (in Barrels) | 20.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC012 |
2013-S01 | Produced Fluid (in Barrels) | 2,120.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S02 | Produced Fluid (in Barrels) | 60.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC012 |
2013-S02 | Produced Fluid (in Barrels) | 146.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S01 | Produced Fluid (in Barrels) | 258.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S02 | Produced Fluid (in Barrels) | 253.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S01 | Produced Fluid (in Barrels) | 345.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Fracing Fluid Waste (in Barrels) | 40.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015-S02 | Produced Fluid (in Barrels) | 25.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015-S02 | Produced Fluid (in Barrels) | 2.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M05 | Produced Fluid (in Barrels) RWC 802 | 19.17 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016-M06 | Produced Fluid (in Barrels) RWC 802 | 53.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016-M08 | Produced Fluid (in Barrels) RWC 802 | 18.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016-M10 | Produced Fluid (in Barrels) RWC 802 | 17.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016-M11 | Produced Fluid (in Barrels) RWC 802 | 34.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016-M12 | Produced Fluid (in Barrels) RWC 802 | 90.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 25.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 36.00 Bbl | REUSE (AT WELL PAD) | |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 94.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 50.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 47.00 Bbl | REUSE (AT WELL PAD) | |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 91.00 Bbl | REUSE (AT WELL PAD) | |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 43.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 21.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 83.25 Bbl | REUSE (AT WELL PAD) | |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 19.25 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 38.25 Bbl | REUSE (AT WELL PAD) | |
2017-M10 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 19.17 Bbl | REUSE (AT WELL PAD) | |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 60.00 Bbl | REUSE (AT WELL PAD) | |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 79.17 Bbl | REUSE (AT WELL PAD) | |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 19.17 Bbl | REUSE (AT WELL PAD) | |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 43.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 19.17 Bbl | REUSE (AT WELL PAD) | |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 21.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-M03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 18.33 Bbl | REUSE (AT WELL PAD) | |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 50.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 20.00 Bbl | REUSE (AT WELL PAD) | |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 68.33 Bbl | REUSE (AT WELL PAD) | |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 25.00 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 71.67 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 25.00 Bbl | REUSE (AT WELL PAD) | |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 46.67 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 21.67 Bbl | REUSE (AT WELL PAD) | |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 65.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 43.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 21.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 21.67 Bbl | REUSE (AT WELL PAD) | |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 21.67 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 21.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 19.17 Bbl | REUSE (AT WELL PAD) | |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 21.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2009855 | Primary Facility | 2011-10-11 | Routine/Complete Inspection | No Violations Noted | access road sediment runoff into state forest. viols charged to 13H |
2068545 | Primary Facility | 2012-05-16 | Follow-up Inspection | No Violations Noted | closing E&S viols. fracking 6 gas wells |
2073985 | Primary Facility | 2012-06-01 | Compliance Evaluation | No Violations Noted | frackin, 10 brl frack fluid release from valve under pressure |
2253292 | Primary Facility | 2014-03-11 | Incident- Response to Accident or Event | No Violations Noted | Production liquid leaked out behind separators when flange developed hole. Violations cited to escgp |
2312583 | Primary Facility | 2014-10-14 | Follow-up Inspection | No Violations Noted | Clossing violations from 11 MAR 2014, when production liquid leaked out of flow line. |
2592675 | Primary Facility | 2017-05-03 | Routine/Partial Inspection | No Violations Noted | This is an inspection of DCNR 595 Pad E.
Electrical conductivity readings w an Oakton PCSTestr 35: production tank containment--0.13 mS/cm, separator containment--0.15 mS/cm, pad--1.2 mS/cm. Onsite during this inspection were 2 Seneca workers tending to the separators. The basin down gradient of the pad (photo) is not on the plan drawing. The basin along the access road (photo) is listed as a "rain garden" on the plan. Time: ~1500-1555 hrs |
2820642 | Primary Facility | 2018-12-28 | Site Restoration | No Violations Noted | This inspection covers DCNR 595 Pad E (not Pads C & G).
NOT denied. Slopes around the pad are temporarily stabilized with hydroseed and sparse vegetation (photo 2). Filter sock (photo 1) is considered a temporary E & S control and hydro seed temporary stabilization; ESCGP termination requires "permanent stabilization", and removal of temporary E & S controls. I took electrical conductivity readings from pooled water on site with an Oakton PCSTestr 35. A puddle near the production tanks returned 0.17 mS/cm. Air temp: 45F JLP |
For data sources see[7]