| Well ID: 37-117-21336 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.585297,"lon":-76.980447,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Tioga | |
| Municipality: Union Township | |
| Operator Name: SWEPI LP | |
| Well Pad ID: | |
| Farm/Lease Name: YAGGIE T 704 6H | |
| License Status: Plugged OG Well | |
| Spud Date: 2011-10-19 | |
| Permit Date: 2011-10-05 | |
| Unconventional Well: Y | |
| Configuration: Horizontal Well | |
| Latitude: 41.585297 | |
| Longitude: -76.980447 |
| Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
|---|---|---|---|---|---|
| 1 | 2012-03-06 | 2012-03-06 | 5480.00 | 3,121,104.0 |
| Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
|---|---|---|---|---|---|---|---|---|
| 1 | Plexgel Breaker | Chemplex | Enzyme Breaker | not classified as hazardous | 100.00 | 0.00020000 | ||
| PetroFlow | Bio-Cide International | Biocide | Sodium chlorite | 7758-19-2 | 8.35 | 0.00379000 | ||
| Sodium chloride | 7647-14-5 | 1.00 | 0.04 | |||||
| Sodium hydroxide | 1310-73-2 | 1.00 | 0.04 | |||||
| Sodium carbonate | 497-19-8 | 2.00 | 0.09 | |||||
| Water | 7732-18-5 | 87.65 | 0.03 | |||||
| FR-900 | Nalco | Scale Inhibitor | not classified as hazardous | 100.00 | 0.06 | |||
| Sand | Badger Mining Co. | Proppant | Quartz | 14808-60-7 | 99.90 | 6.07 | ||
| Plex 907 | Chemplex | Gelling Agent/Thickener | vegetable gums | 100.00 | 0.02 | |||
| Hydrochloric Acid | Reagent Chemical & Research | Hydrochloric acid | 7647-01-0 | 15.00 | 0.06 | |||
| Water | 85.00 | 0.35 | ||||||
| Water | Shell | 100.00 | 93.77 | |||||
| MSI-7 | National Petrochemical | Scale Inhibitor | Hydorgen Chloride | 0.00925000 | ||||
| I-22 | Nalco | Acid Corrosion Inhibitor | Methanol | 67-56-1 | 5.00 | 0.00002000 | ||
| Aromatic aldehyde | 30.00 | 0.00012000 | ||||||
| Isopropanol | 67-63-0 | 5.00 | 0.00002000 | |||||
| Oxyalkylated Fatty Acid | 30.00 | 0.00012000 | ||||||
| Quaternary ammonium compounds | 5.00 | 0.00002000 | ||||||
| Benzyl chloride | 100-44-7 | 1.00 | 0.00 | |||||
| Haloalkyl heteropolycycle salt | 30.00 | 0.00012000 | ||||||
| Formic acid | 64-18-6 | 60.00 | 0.00025000 | |||||
| Organic sulfur compounds | 5.00 | 0.00002000 | ||||||
| FE-4 | Univar | Iron Control/Reducer | Citric acid | 77-92-9 | 50.00 | 0.00062000 | ||
| Water | 7732-18-5 | 50.00 | 0.00062000 |
For data sources see[4]
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2011 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2012 | SWEPI LP | 42,247.27 | 131 | 0.00 | 0 | 0.00 | 0 |
| 2013 | SWEPI LP | 17,365.92 | 100 | 0.00 | 0 | 0.00 | 0 |
| 2014 | SWEPI LP | 3,018.93 | 3 | 0.00 | 0 | 0.00 | 0 |
| 2015 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2016 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
| Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|
| 2012-S01 | Drill Cuttings (in Tons) | 596.85 Tons | LANDFILL | 9312 |
| 2012-S02 | Drilling Fluid Waste (in Barrels) | 11.90 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
| 2012-S02 | Fracing Fluid Waste (in Barrels) | 2,286.99 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
| 2012-S02 | Fracing Fluid Waste (in Barrels) | 1,362.68 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
| 2012-S02 | Fracing Fluid Waste (in Barrels) | 395.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW018 |
| 2012-S02 | Fracing Fluid Waste (in Barrels) | 3,134.07 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2012-S02 | Produced Fluid (in Barrels) | 89.68 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2013-S01 | Drilling Fluid Waste (in Barrels) | 190.89 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2013-S01 | Fracing Fluid Waste (in Barrels) | 436.28 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2013-S01 | Produced Fluid (in Barrels) | 335.06 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
| 2013-S01 | Produced Fluid (in Barrels) | 69.55 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2013-S01 | Produced Fluid (in Barrels) | 2,691.62 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2013-S02 | Drilling Fluid Waste (in Barrels) | 105.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2013-S02 | Produced Fluid (in Barrels) | 36.68 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2013-S02 | Produced Fluid (in Barrels) | 368.11 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2014-S01 | Fracing Fluid Waste (in Barrels) | 53.98 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2014-S01 | Produced Fluid (in Barrels) | 20.86 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2014-S01 | Produced Fluid (in Barrels) | 149.63 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2015-S01 | Produced Fluid (in Barrels) | 34.34 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2015-S01 | Produced Fluid (in Barrels) | 67.68 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
| 2015-S01 | Produced Fluid (in Barrels) | 0.17 Bbl | REUSE OTHER THAN ROAD SPREADING |
For data sources see[6]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 2070433 | Primary Facility | 2012-05-09 | Routine/Complete Inspection | No Violations Noted | Wells vented, bubbling found on 5H well, no E%S issues. No Vio |
| 2084160 | Primary Facility | 2012-07-03 | Follow-up Inspection | No Violations Noted | |
| 2085497 | Primary Facility | 2012-07-23 | Incident- Response to Accident or Event | No Violations Noted | |
| 2086107 | Primary Facility | 2012-06-22 | Incident- Response to Accident or Event | Viol(s) Noted & Immediately Corrected | small brine spill (mist) during flaring VIOIC |
| 2115846 | Primary Facility | 2012-11-07 | Routine/Complete Inspection | No Violations Noted | Spill of produced water to the pad surface almost completely vacuumed. excavation required. |
| 2209462 | Primary Facility | 2013-09-25 | Compliance Evaluation | No Violations Noted | Previous Violations cited to the 37-117-21334 (11-7-12) permit have been resolved. No new violations |
| 2368841 | Primary Facility | 2015-02-27 | Routine/Complete Inspection | No Violations Noted | |
| 2464461 | Primary Facility | 2016-03-07 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | |
| 2487710 | Primary Facility | 2016-05-24 | Routine/Complete Inspection | No Violations Noted |
| Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
|---|---|---|---|---|---|---|
| 2086107 | 644878 | 06/22/2012 | 2012-06-22 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | small brine spill (mist) during flaring VIOIC |
| 2086107 | 644879 | 06/22/2012 | 2012-06-22 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | small brine spill (mist) during flaring VIOIC |
For data sources see[7]