37-117-21633

Well Details

Well ID: 37-117-21633
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Sullivan Township
Operator Name: SWEPI LP
Well Pad ID: 147391
Farm/Lease Name: FLACK 502W 4H
License Status: Active
Spud Date: 2013-06-04
Permit Date: 2013-05-22
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.828939
Longitude: -76.976333

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-10-11 2013-10-11 5366 3,151,680.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water, Customer & CWS Base Fluid & Mix Water, Water 7732-18-5 100 86.0258 26,402,200.0
Sand (Proppant), DAP-902, DAP-925,
DWP-111, DWP-602, DWP-901,
BioClear 2000, Hydrochloric Acid,
CWS Propping Agent, Scale Inhibitor, Acid Corrosion Inhibitor, Gel Slurry, Friction Reducer, Breaker, Biocide, Clean Perforations, Methanol 67-56-1 60 0.0001 40.88
Paraffinic hydrocarbon solvent 64742-47-8 30 0.0213 6528.62
Polyoxyalkylenes Proprietary 30 0.0001 20.44
Polyoxyalkylenes surfactant Proprietary 5 0.0035 1088.1
Nonionic surfactant Proprietary 5 0.0035 1088.1
Distillates (petroleum), hydrotreated middle 64742-46-7 60 0.0009 263.71
Apatite 64476-38-6 0.1 0.0045 1366.68
Propargyl Alcohol 107-19-7 10 0 6.81
Oxirane, 2-methyl-, polymer with oxirane, monodecyl ether 37251-67-5 1.5 0 6.59
Guar gum 9000-30-0 60 0.0009 263.71
Sodium chloride 7647-14-5 1 0 0.68
Goethite 1310-14-1 0.1 0.0065 1996.94
Polyethylene Glycol Mixture 25322-68-3 70 0.0127 3885.19
Ilmenite 98072-94-7 0.1 0.0034 1051.55
Modified thiourea polymer 68527-49-1 30 0.0001 20.44
Olefin Proprietary 5 0 3.41
Illite 12173-60-3 1 0.0093 2839.18
Fatty acids Proprietary 30 0.0001 20.44
Ammonium Persulfate 7727-54-0 100 0.0003 83.4
Quaternary ammonium compounds,
bis(hydrogenated tallow alkyl)dimethyl,
salts with bentonite
68953-58-2 5 0.0001 21.98
Formaldehyde 50-00-0 0.1 0 0.07
1,2-Propanediol 57-55-6 10 0.0015 468.37
Calcite 471-34-1 1 0.0216 6617.73
Organic acid salts Proprietary 40 0.0061 1873.5
2,2-Dibromo-3-Nitrilopropionamide 10222-01-2 40 0.0127 3885.19
Crystalline silica (Quartz) 14808-60-7 100 13.6352 4,184,790.0
Biotite 1302-27-8 0.1 0.0045 1366.68
Hydrochloric acid 7647-01-0 37 0.1972 60520.9
Polyacrylamide polymer Proprietary 40 0.0284 8704.82

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 SWEPI LP 76,117.12 18 0.00 0 0.00 0
2014 SWEPI LP 1,482,335.54 345 0.00 0 0.00 0
2015 SWEPI LP 1,074,206.25 362 0.00 0 0.00 0
2016 SWEPI LP 757,401.73 364 0.00 0 0.00 0
2017 SWEPI LP 468,785.29 363 0.00 0 0.00 0
2018 SWEPI LP 442,876.11 364 0.00 0 0.00 0
2019 SWEPI LP 96,560.35 87 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2013-S01 Drill Cuttings (in Tons) 174.20 Tons LANDFILL 301358
2013-S01 Drilling Fluid Waste (in Barrels) 111.99 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC006
2013-S02 Drill Cuttings (in Tons) 619.90 Tons LANDFILL 301358
2013-S02 Drilling Fluid Waste (in Barrels) 374.61 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013-S02 Drilling Fluid Waste (in Barrels) 315.68 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC006
2013-S02 Drilling Fluid Waste (in Barrels) 468.71 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Fracing Fluid Waste (in Barrels) 73.32 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013-S02 Fracing Fluid Waste (in Barrels) 1.75 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2013-S02 Fracing Fluid Waste (in Barrels) 8,669.18 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S01 Fracing Fluid Waste (in Barrels) 294.45 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S01 Produced Fluid (in Barrels) 222.82 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-S01 Produced Fluid (in Barrels) 344.47 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014-S01 Produced Fluid (in Barrels) 2,823.50 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S02 Produced Fluid (in Barrels) 62.34 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-S02 Produced Fluid (in Barrels) 385.92 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014-S02 Produced Fluid (in Barrels) 515.30 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Fracing Fluid Waste (in Barrels) 36.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015-S01 Produced Fluid (in Barrels) 87.14 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015-S01 Produced Fluid (in Barrels) 16.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015-S01 Produced Fluid (in Barrels) 199.98 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC011
2015-S01 Produced Fluid (in Barrels) 268.44 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015-S01 Produced Fluid (in Barrels) 523.98 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Produced Fluid (in Barrels) 433.14 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015-S02 Produced Fluid (in Barrels) 866.97 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Produced Fluid (in Barrels) RWC 802 18.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016-S01 Produced Fluid (in Barrels) RWC 802 620.29 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S02 Produced Fluid (in Barrels) RWC 802 33.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016-S02 Produced Fluid (in Barrels) RWC 802 666.60 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M01 Produced Fluid (in Barrels) RWC 802 166.65 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017-M01 Produced Fluid (in Barrels) RWC 802 33.33 Bbl REUSE (AT WELL PAD)
2017-M02 Produced Fluid (in Barrels) RWC 802 1.89 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017-M02 Produced Fluid (in Barrels) RWC 802 73.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M02 Produced Fluid (in Barrels) RWC 802 399.96 Bbl REUSE (AT WELL PAD)
2017-M03 Produced Fluid (in Barrels) RWC 802 166.67 Bbl REUSE (AT WELL PAD)
2017-M04 Produced Fluid (in Barrels) RWC 802 33.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M04 Produced Fluid (in Barrels) RWC 802 33.33 Bbl REUSE (AT WELL PAD)
2017-M05 Produced Fluid (in Barrels) RWC 802 46.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M06 Produced Fluid (in Barrels) RWC 802 1.00 Bbl REUSE (AT WELL PAD)
2017-M08 Produced Fluid (in Barrels) RWC 802 133.33 Bbl REUSE (AT WELL PAD)
2017-M09 Produced Fluid (in Barrels) RWC 802 166.66 Bbl REUSE (AT WELL PAD)
2017-M10 Produced Fluid (in Barrels) RWC 802 133.32 Bbl REUSE (AT WELL PAD)
2017-M11 Produced Fluid (in Barrels) RWC 802 100.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-M01 Produced Fluid (in Barrels) RWC 802 23.67 Bbl REUSE (AT WELL PAD)
2018-M04 Produced Fluid (in Barrels) RWC 802 232.66 Bbl REUSE (AT WELL PAD)
2018-M05 Produced Fluid (in Barrels) RWC 802 23.81 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-M05 Produced Fluid (in Barrels) RWC 802 38.32 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-M06 Produced Fluid (in Barrels) RWC 802 100.00 Bbl REUSE (AT WELL PAD)
2018-M07 Produced Fluid (in Barrels) RWC 802 33.33 Bbl REUSE (AT WELL PAD)
2018-M08 Produced Fluid (in Barrels) RWC 802 66.67 Bbl REUSE (AT WELL PAD)
2018-M09 Produced Fluid (in Barrels) RWC 802 133.33 Bbl REUSE (AT WELL PAD)
2018-M12 Produced Fluid (in Barrels) RWC 802 216.66 Bbl REUSE (AT WELL PAD)
2019-M01 Produced Fluid (in Barrels) RWC 802 100.00 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Barrels) RWC 802 66.67 Bbl REUSE (AT WELL PAD)
2019-M03 Produced Fluid (in Barrels) RWC 802 133.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2168977 Primary Facility 2013-05-23 Routine/Complete Inspection No Violations Noted Pre Spud
2201514 Primary Facility 2013-09-04 Routine/Complete Inspection No Violations Noted
2219219 Primary Facility 2013-11-05 Routine/Complete Inspection No Violations Noted
2230191 Primary Facility 2013-12-17 Routine/Partial Inspection No Violations Noted Flow back spill, 1 brl, reported on December 4. today a small leak found at connection, 14 mS/cm on pad
2272647 Primary Facility 2014-05-21 Follow-up Inspection No Violations Noted
2318894 Primary Facility 2014-10-01 Follow-up Inspection No Violations Noted
2397915 Primary Facility 2015-07-16 Site Restoration No Violations Noted NOT recommended for approval. 3 Marcellus gas wells producing.
2502609 Primary Facility 2016-07-19 Routine/Complete Inspection No Violations Noted
2594190 Primary Facility 2017-05-16 Routine/Partial Inspection No Violations Noted EC readings w an Oakton APCTestr 35: production tank containment--0.77 mS/cm, pad--0.19 mS/cm. On site ~1300-1515 hrs.
2709460 Primary Facility 2018-03-23 Routine/Partial Inspection No Violations Noted I took electrical conductivity readings from standing liquid with an Oakton PCSTestr 35. I did not see any puddles on the pad. Air temp 41F. JLP
2788064 Primary Facility 2018-10-12 Routine/Complete Inspection No Violations Noted Cool/windy at time of inspection.
2854060 Primary Facility 2019-03-14 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of SWEPI's Flack/McConnell 502 Well Site in Sullivan Twp, Tioga County on 3/14/2019 at 1230 hours. The weather was sunny and 56 degrees. The act 9 sign was observed at the entrance to the site. The E&S Plan and inspection log were available for review in the mailbox at the entrance. Company personnel last inspected the site on 3/12/2019 noting no issues.

There are currently 3 wells onsite in producing, the 2H, 4H & 6H. The site has very steep slopes but they are vegetated very well and no erosion was observed. PCSM BMPs are installed per plan and functioning. Containment structures are intact and functioning and no leaks or releases were observed. Puddles on the pad were within normal conductivity ranges.

No violations or issues noted today, I departed the site at 1310.

For data sources see[7]

References