If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-117-21633 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.828939,"lon":-76.976333,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Sullivan Township | |
Operator Name: SWEPI LP | |
Well Pad ID: 147391 | |
Farm/Lease Name: FLACK 502W 4H | |
License Status: Active | |
Spud Date: 2013-06-04 | |
Permit Date: 2013-05-22 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.828939 | |
Longitude: -76.976333 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-10-11 | 2013-10-11 | 5366 | 3,151,680.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Water, | Customer & CWS | Base Fluid & Mix Water, | Water | 7732-18-5 | 100 | 86.0258 | 26,402,200.0 |
Sand (Proppant), DAP-902, DAP-925, DWP-111, DWP-602, DWP-901, BioClear 2000, Hydrochloric Acid, |
CWS | Propping Agent, Scale Inhibitor, Acid Corrosion Inhibitor, Gel Slurry, Friction Reducer, Breaker, Biocide, Clean Perforations, | Methanol | 67-56-1 | 60 | 0.0001 | 40.88 | |
Paraffinic hydrocarbon solvent | 64742-47-8 | 30 | 0.0213 | 6528.62 | ||||
Polyoxyalkylenes | Proprietary | 30 | 0.0001 | 20.44 | ||||
Polyoxyalkylenes surfactant | Proprietary | 5 | 0.0035 | 1088.1 | ||||
Nonionic surfactant | Proprietary | 5 | 0.0035 | 1088.1 | ||||
Distillates (petroleum), hydrotreated middle | 64742-46-7 | 60 | 0.0009 | 263.71 | ||||
Apatite | 64476-38-6 | 0.1 | 0.0045 | 1366.68 | ||||
Propargyl Alcohol | 107-19-7 | 10 | 0 | 6.81 | ||||
Oxirane, 2-methyl-, polymer with oxirane, monodecyl ether | 37251-67-5 | 1.5 | 0 | 6.59 | ||||
Guar gum | 9000-30-0 | 60 | 0.0009 | 263.71 | ||||
Sodium chloride | 7647-14-5 | 1 | 0 | 0.68 | ||||
Goethite | 1310-14-1 | 0.1 | 0.0065 | 1996.94 | ||||
Polyethylene Glycol Mixture | 25322-68-3 | 70 | 0.0127 | 3885.19 | ||||
Ilmenite | 98072-94-7 | 0.1 | 0.0034 | 1051.55 | ||||
Modified thiourea polymer | 68527-49-1 | 30 | 0.0001 | 20.44 | ||||
Olefin | Proprietary | 5 | 0 | 3.41 | ||||
Illite | 12173-60-3 | 1 | 0.0093 | 2839.18 | ||||
Fatty acids | Proprietary | 30 | 0.0001 | 20.44 | ||||
Ammonium Persulfate | 7727-54-0 | 100 | 0.0003 | 83.4 | ||||
Quaternary ammonium compounds, bis(hydrogenated tallow alkyl)dimethyl, salts with bentonite |
68953-58-2 | 5 | 0.0001 | 21.98 | ||||
Formaldehyde | 50-00-0 | 0.1 | 0 | 0.07 | ||||
1,2-Propanediol | 57-55-6 | 10 | 0.0015 | 468.37 | ||||
Calcite | 471-34-1 | 1 | 0.0216 | 6617.73 | ||||
Organic acid salts | Proprietary | 40 | 0.0061 | 1873.5 | ||||
2,2-Dibromo-3-Nitrilopropionamide | 10222-01-2 | 40 | 0.0127 | 3885.19 | ||||
Crystalline silica (Quartz) | 14808-60-7 | 100 | 13.6352 | 4,184,790.0 | ||||
Biotite | 1302-27-8 | 0.1 | 0.0045 | 1366.68 | ||||
Hydrochloric acid | 7647-01-0 | 37 | 0.1972 | 60520.9 | ||||
Polyacrylamide polymer | Proprietary | 40 | 0.0284 | 8704.82 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | SWEPI LP | 76,117.12 | 18 | 0.00 | 0 | 0.00 | 0 |
2014 | SWEPI LP | 1,482,335.54 | 345 | 0.00 | 0 | 0.00 | 0 |
2015 | SWEPI LP | 1,074,206.25 | 362 | 0.00 | 0 | 0.00 | 0 |
2016 | SWEPI LP | 757,401.73 | 364 | 0.00 | 0 | 0.00 | 0 |
2017 | SWEPI LP | 468,785.29 | 363 | 0.00 | 0 | 0.00 | 0 |
2018 | SWEPI LP | 442,876.11 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | SWEPI LP | 96,560.35 | 87 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2013-S01 | Drill Cuttings (in Tons) | 174.20 Tons | LANDFILL | 301358 |
2013-S01 | Drilling Fluid Waste (in Barrels) | 111.99 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC006 |
2013-S02 | Drill Cuttings (in Tons) | 619.90 Tons | LANDFILL | 301358 |
2013-S02 | Drilling Fluid Waste (in Barrels) | 374.61 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013-S02 | Drilling Fluid Waste (in Barrels) | 315.68 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC006 |
2013-S02 | Drilling Fluid Waste (in Barrels) | 468.71 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S02 | Fracing Fluid Waste (in Barrels) | 73.32 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013-S02 | Fracing Fluid Waste (in Barrels) | 1.75 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 7-3115-00193 |
2013-S02 | Fracing Fluid Waste (in Barrels) | 8,669.18 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S01 | Fracing Fluid Waste (in Barrels) | 294.45 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S01 | Produced Fluid (in Barrels) | 222.82 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014-S01 | Produced Fluid (in Barrels) | 344.47 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014-S01 | Produced Fluid (in Barrels) | 2,823.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S02 | Produced Fluid (in Barrels) | 62.34 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014-S02 | Produced Fluid (in Barrels) | 385.92 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2014-S02 | Produced Fluid (in Barrels) | 515.30 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S01 | Fracing Fluid Waste (in Barrels) | 36.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015-S01 | Produced Fluid (in Barrels) | 87.14 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015-S01 | Produced Fluid (in Barrels) | 16.67 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015-S01 | Produced Fluid (in Barrels) | 199.98 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC011 |
2015-S01 | Produced Fluid (in Barrels) | 268.44 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015-S01 | Produced Fluid (in Barrels) | 523.98 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Produced Fluid (in Barrels) | 433.14 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015-S02 | Produced Fluid (in Barrels) | 866.97 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 18.33 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 620.29 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 666.60 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 166.65 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | REUSE (AT WELL PAD) | |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 1.89 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 73.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 399.96 Bbl | REUSE (AT WELL PAD) | |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 166.67 Bbl | REUSE (AT WELL PAD) | |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | REUSE (AT WELL PAD) | |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 46.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 1.00 Bbl | REUSE (AT WELL PAD) | |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 133.33 Bbl | REUSE (AT WELL PAD) | |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 166.66 Bbl | REUSE (AT WELL PAD) | |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 133.32 Bbl | REUSE (AT WELL PAD) | |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 100.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 23.67 Bbl | REUSE (AT WELL PAD) | |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 232.66 Bbl | REUSE (AT WELL PAD) | |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 23.81 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 38.32 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 100.00 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | REUSE (AT WELL PAD) | |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 66.67 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 133.33 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 216.66 Bbl | REUSE (AT WELL PAD) | |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 100.00 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 66.67 Bbl | REUSE (AT WELL PAD) | |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 133.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2168977 | Primary Facility | 2013-05-23 | Routine/Complete Inspection | No Violations Noted | Pre Spud |
2201514 | Primary Facility | 2013-09-04 | Routine/Complete Inspection | No Violations Noted | |
2219219 | Primary Facility | 2013-11-05 | Routine/Complete Inspection | No Violations Noted | |
2230191 | Primary Facility | 2013-12-17 | Routine/Partial Inspection | No Violations Noted | Flow back spill, 1 brl, reported on December 4. today a small leak found at connection, 14 mS/cm on pad |
2272647 | Primary Facility | 2014-05-21 | Follow-up Inspection | No Violations Noted | |
2318894 | Primary Facility | 2014-10-01 | Follow-up Inspection | No Violations Noted | |
2397915 | Primary Facility | 2015-07-16 | Site Restoration | No Violations Noted | NOT recommended for approval. 3 Marcellus gas wells producing. |
2502609 | Primary Facility | 2016-07-19 | Routine/Complete Inspection | No Violations Noted | |
2594190 | Primary Facility | 2017-05-16 | Routine/Partial Inspection | No Violations Noted | EC readings w an Oakton APCTestr 35: production tank containment--0.77 mS/cm, pad--0.19 mS/cm. On site ~1300-1515 hrs. |
2709460 | Primary Facility | 2018-03-23 | Routine/Partial Inspection | No Violations Noted | I took electrical conductivity readings from standing liquid with an Oakton PCSTestr 35. I did not see any puddles on the pad. Air temp 41F. JLP |
2788064 | Primary Facility | 2018-10-12 | Routine/Complete Inspection | No Violations Noted | Cool/windy at time of inspection. |
2854060 | Primary Facility | 2019-03-14 | Routine/Complete Inspection | No Violations Noted | The DEP conducted a routine inspection of SWEPI's Flack/McConnell 502 Well Site in Sullivan Twp, Tioga County on 3/14/2019 at 1230 hours. The weather was sunny and 56 degrees. The act 9 sign was observed at the entrance to the site. The E&S Plan and inspection log were available for review in the mailbox at the entrance. Company personnel last inspected the site on 3/12/2019 noting no issues.
There are currently 3 wells onsite in producing, the 2H, 4H & 6H. The site has very steep slopes but they are vegetated very well and no erosion was observed. PCSM BMPs are installed per plan and functioning. Containment structures are intact and functioning and no leaks or releases were observed. Puddles on the pad were within normal conductivity ranges. No violations or issues noted today, I departed the site at 1310. |
For data sources see[7]