37-117-21981

Well Details

Well ID: 37-117-21981
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Union Township
Operator Name: ROCKDALE MARCELLUS LLC
Well Pad ID: 149555
Farm/Lease Name: WESNESKI 724 2H
License Status: Active
Spud Date: 2018-06-18
Permit Date: 2018-04-19
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.621733
Longitude: -76.897428

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2018 ROCKDALE MARCELLUS LLC 429,978.00 74 0.00 0 0.00 0
2019 ROCKDALE MARCELLUS LLC 485,075.00 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2018-M07 Drill Cuttings (in Tons) RWC 810 361.07 Tons LANDFILL 301358
2018-M07 Other Oil & Gas Wastes (in Barrels) RWC 899 104.84 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-M07 Other Oil & Gas Wastes (in Barrels) RWC 899 55.95 Bbl REUSE (AT WELL PAD)
2018-M07 Produced Fluid (in Barrels) RWC 802 47.57 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-M07 Produced Fluid (in Barrels) RWC 802 20.00 Bbl REUSE (AT WELL PAD)
2018-M08 Drill Cuttings (in Tons) RWC 810 271.53 Tons LANDFILL 301358
2018-M08 Other Oil & Gas Wastes (in Barrels) RWC 899 185.00 Bbl REUSE (AT WELL PAD)
2018-M08 Produced Fluid (in Barrels) RWC 802 237.50 Bbl REUSE (AT WELL PAD)
2018-M08 Synthetic Liner Materials (in Tons) RWC 806 1.95 Tons LANDFILL 301358
2018-M09 Drill Cuttings (in Tons) RWC 810 451.48 Tons LANDFILL 301358
2018-M09 Drilling Fluid Waste (in Barrels) RWC 803 1,057.50 Bbl REUSE (AT WELL PAD)
2018-M09 Synthetic Liner Materials (in Tons) RWC 806 11.03 Tons LANDFILL 301358
2018-M10 Drilling Fluid Waste (in Barrels) RWC 803 265.50 Bbl REUSE (AT WELL PAD)
2018-M10 Other Oil & Gas Wastes (in Barrels) RWC 899 595.00 Bbl REUSE (AT WELL PAD)
2018-M10 Produced Fluid (in Barrels) RWC 802 6,687.50 Bbl REUSE (AT WELL PAD)
2018-M10 Synthetic Liner Materials (in Tons) RWC 806 8.31 Tons LANDFILL 301358
2018-M11 Other Oil & Gas Wastes (in Barrels) RWC 899 345.00 Bbl REUSE (AT WELL PAD)
2018-M11 Produced Fluid (in Barrels) RWC 802 307.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2018-M11 Produced Fluid (in Barrels) RWC 802 11,212.53 Bbl REUSE (AT WELL PAD)
2018-M12 Produced Fluid (in Barrels) RWC 802 577.50 Bbl REUSE (AT WELL PAD)
2018-M12 Produced Fluid (in Tons) RWC 802 48.16 Tons LANDFILL 301358
2018-M12 Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 24.53 Tons LANDFILL 301358
2018-M12 Synthetic Liner Materials (in Tons) RWC 806 2.18 Tons LANDFILL 301358
2019-M01 Produced Fluid (in Barrels) RWC 802 310.00 Bbl REUSE (AT WELL PAD)
2019-M02 Other Oil & Gas Wastes (in Barrels) RWC 899 513.33 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Barrels) RWC 802 2,635.50 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Tons) RWC 802 7.45 Tons LANDFILL 301358
2019-M02 Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 19.39 Tons LANDFILL 301358
2019-M03 Other Oil & Gas Wastes (in Barrels) RWC 899 91.00 Bbl REUSE (AT WELL PAD)
2019-M03 Produced Fluid (in Barrels) RWC 802 285.50 Bbl REUSE (AT WELL PAD)
2019-M03 Produced Fluid (in Tons) RWC 802 33.90 Tons LANDFILL 301358
2019-M03 Synthetic Liner Materials (in Tons) RWC 806 4.06 Tons LANDFILL 301358

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2743910 Primary Facility 2018-06-21 Routine/Complete Inspection No Violations Noted Waiting on cement truck to cement cellars.
2755221 Primary Facility 2018-07-24 Routine/Complete Inspection No Violations Noted Weather was 74 degrees F. and raining. It had been raining for a few days prior to inspection. Met with Rockdale Marcellus representative Jimmy Larsen on location. Rig was in the process of waiting on cement after the cement surface casing job. At the end of the job when the plug bumped the casing jumped out of the slips and then settled back to its original position. When the cement company released the pressure to check the floats it was determined that either the casing had parted or the floats were not holding. They then closed in the casing and held 193 psi on the casing. They intend on running a bond log at approximately 7pm. They are waiting approximately 12 hours from plug bump to ensure cement integrity. Reviewed the cement job log and no discrepancies were noted at time of inspection. Performed a walk around inspection of location. No violations noted at time of inspection.
2760876 Primary Facility 2018-08-06 Routine/Complete Inspection No Violations Noted Weather was 72° and sunny at time of inspection. Met with Rockdale Marcellus representative Jimmy Larsen at time of inspection. Well was a spud conductor. Well was covered with a rig mat at time of inspection. No violations noted at time of inspection.
2771612 Primary Facility 2018-09-06 Routine/Complete Inspection No Violations Noted Weather was 78° and sunny at time of inspection. Met with Rockdale Marcellus representative Danny Brooks on location. Rig had drilled the well to TD on 9/5/18. Rig was in the process of circulating 2 bottoms up before the cement job. Halliburton was on location to complete the cement job for the production casing. Reviewed the cement job program and no discrepancies were noted. When this well is complete the rig will move over to the 4H. No violations were noted at time of inspection.
2776844 Primary Facility 2018-09-19 Routine/Complete Inspection No Violations Noted Weather was 70° and cloudy at time of inspection. There were no Rockdale Marsellus representatives on location at time of inspection. Well had recently been drilled and cemented to TD. Well has a nightcap installed. There was a 0-5k psi analog gauge attached to the top of the nightcap that read 0 psi at time of inspection. The mouse hole had a steel plate sitting on it. No violations noted at time of inspection.
2790871 Primary Facility 2018-10-17 Routine/Complete Inspection Pending I met Luke Chesner and Marc McCartor of Rockdale when I arrived. The frac was temporarily on hold because there was not yet enough water in the MASS to begin the next stages. The area around the MASS looked good overall, with all puddles on the ground surface showing low conductance (.11-.56 mS/ cm). One of the large pump containments had several inches of water in it that showed slightly elevated conductance (2.56 mS/cm). Walking around the sitewide containment, the liner and berms appeared to be in good condition, and most puddles were low in conductance (.4-.83 mS/cm). Large (approximately 12" diameter) collapsible hoses were run from the MASS onto the sitewide containment, and one of these hoses was compressing a foam berm. When I informed Luke, he told me he would have the containment vacced and prop up the 12" water line over the berm. A vac truck was working on the sitewide containment caddy corner from the entrance; immediately outside of this containment I discovered an approximately 15-20 ga
2790926 Primary Facility 2018-10-17 Routine/Complete Inspection Pending I met Luke Chesner and Marc McCartor of Rockdale when I arrived. The frac was temporarily on hold because there was not yet enough water in the MASS to begin the next stages. The area around the MASS looked good overall, with all puddles on the ground surface showing low conductance (.11-.56 mS/ cm). One of the large pump containments had several inches of water in it that showed slightly elevated conductance (2.56 mS/cm). Walking around the sitewide containment, the liner and berms appeared to be in good condition, and most puddles were low in conductance (.4-.83 mS/cm). Large (approximately 12" diameter) collapsible hoses were run from the MASS onto the sitewide containment, and one of these hoses was compressing a foam berm. When I informed Luke, he told me he would have the containment vacced and prop up the 12" water line over the berm. A vac truck was working on the sitewide containment caddy corner from the entrance; immediately outside of this containment I discovered an approximately 15-20 ga
2803376 Primary Facility 2018-11-15 Administrative/File Review No Violations Noted Results were received for sample ID #0939077 taken on 10/17/2018 (see pictures). Sample was taken from a 15-20gallon puddle located outside of containment. Elevated barium, strontium, and chlorides indicate that the fluid on the pad was wastewater; the result of the administrative inspection is Violations Noted.
2825015 Primary Facility 2019-01-09 Routine/Complete Inspection No Violations Noted Light activity on the site when I arrived. 2 temporary sand separators currently hooked up to the recently fraced wells. The onsite modular storage structure was still present, but a worker was pumping water from the tank to a bank of Baker tanks in containment. The area around the MASS was dry, and a downgradient sediment trap nearby showed low conductance (.13 mS/cm). A truck loading area at the Baker tanks had a 10' x 5' (1-2" deep) in front of it that showed slightly elevated conductance; I recommend that the puddle be vacced. The area where I noted fluid with elevated conductance on my 10/17/18 inspection had recently had fresh gravel placed on it.
2853446 Primary Facility 2019-03-13 Routine/Complete Inspection No Violations Noted Routine inspection conducted to assess overall site conditions. Two wells are still in flowback. Batteries of frac tanks are present on the pad within secondary containment. The containment appears to be in good condition overall. An aboveground storage tank is present on site. Several puddles on the pad to the south of the AST had a conductivity of between 1.1 and 1.6 mS/cm. Three GPUs are present n site, are labeled, and appear to be in good condition. Two steel double-walled produced water tanks are present, labeled, and appear to be in good condition.

No violations noted.

For data sources see[6]

References