If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-117-21988 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.594403,"lon":-77.045311,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Liberty Township | |
Operator Name: ROCKDALE MARCELLUS LLC | |
Well Pad ID: 153703 | |
Farm/Lease Name: HARER 713 2H | |
License Status: Active | |
Spud Date: 2018-06-08 | |
Permit Date: 2018-04-19 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.594403 | |
Longitude: -77.045311 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2018-08-07 | 2018-08-29 | 7375.66 | 17,152,700.0 | 171558 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | ScaleTreat 14448 | Clariant | Scale Inhibitor | 2,2',2 - Nitrilotris(acetamide) | 4862-18-4 | 5 | 0.00113 | 1889 |
Ammonium Chloride | 12125-02-9 | 5 | 0.00113 | 1889 | ||||
Methanol | 67-56-1 | 60 | 0.0136 | 22668 | ||||
ProFE 105 | ProFrac | Iron Control | Sulphamic Acid | 5329-14-6 | 5 | 0.00014 | 229 | |
Water | 7732-18-5 | 70 | 0.00192 | 3202 | ||||
Citric Acid | 77-92-9 | 40 | 0.0011 | 1830 | ||||
Water | Rockdale Marcellus | Base Fluid | Water | 7732-18-5 | 100 | 85.8674 | 143,139,000.0 | |
Hydrochloric Acid | FSTI | Acidizing | Water | 7732-18-5 | 72 | 0.56032 | 934042 | |
hydrogen chloride | 7647-01-0 | 28 | 0.2179 | 363238 | ||||
FloTreat DR 15482 | Clariant | Friction Reducer | Alcohols, C10-16, 6 EO | 68002-97-1 | 10 | 0.00641 | 10693 | |
Hydrocarbons C9- C16 | 64742-47-8 | 50 | 0.03207 | 53466 | ||||
BioTreat | Clariant | Biocide | Dideclydimethylammonium Chloride | 7173-51-5 | 3 | 0.00105 | 1752 | |
Glutaraldehyde | 111-30-8 | 20 | 0.00701 | 11679 | ||||
Quaternary Ammonium Chloride | 68424-85-1 | 3 | 0.00105 | 1752 | ||||
Sand 100 Mesh | ProFrac | Proppant | Silica Substrate | 14808-60-7 | 100 | 2.2084 | 3,681,360.0 | |
ProHib 100 | ProFrac | Acid Inhibitor | 2-Propyn-1-ol compound w/ methyloxirane | 38172-91-7 | 15 | 0.00034 | 572 | |
Water | 7732-18-5 | 85 | 0.00194 | 3240 | ||||
Sand 40/70 | ProFrac | Proppant | Silica Substrate | 14808-60-7 | 100 | 11.0191 | 18,368,600.0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2018 | ROCKDALE MARCELLUS LLC | 1,901,018.00 | 122 | 0.00 | 0 | 0.00 | 0 |
2019 | ROCKDALE MARCELLUS LLC | 1,101,157.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2018-M06 | Synthetic Liner Materials (in Tons) RWC 806 | 0.65 Tons | LANDFILL | 301358 |
2018-M07 | Drill Cuttings (in Tons) RWC 810 | 1,377.68 Tons | LANDFILL | 301358 |
2018-M07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 69.24 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018-M07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 90.00 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 645.00 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Synthetic Liner Materials (in Tons) RWC 806 | 4.11 Tons | LANDFILL | 301358 |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 80.00 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 24.00 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 19.80 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 1,910.20 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | 15.84 Tons | LANDFILL | 301358 |
2018-M09 | Synthetic Liner Materials (in Tons) RWC 806 | 2.02 Tons | LANDFILL | 301358 |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 615.00 Bbl | REUSE (AT WELL PAD) | |
2018-M10 | Produced Fluid (in Tons) RWC 802 | 59.50 Tons | LANDFILL | 301358 |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 116.67 Bbl | INJECTION DISPOSAL WELL | PAS2D215BWAR |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 6,762.36 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 773.33 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Synthetic Liner Materials (in Tons) RWC 806 | 3.72 Tons | LANDFILL | 301358 |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 553.33 Bbl | INJECTION DISPOSAL WELL | PAS2D215BWAR |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 1,091.67 Bbl | REUSE (AT WELL PAD) | |
2019-M01 | Synthetic Liner Materials (in Tons) RWC 806 | 1.14 Tons | LANDFILL | 301358 |
2019-M02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 97.78 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 249.67 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Synthetic Liner Materials (in Tons) RWC 806 | 2.31 Tons | LANDFILL | 301358 |
2019-M03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 60.67 Bbl | REUSE (AT WELL PAD) | |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 400.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 201.33 Bbl | REUSE (AT WELL PAD) | |
2019-M03 | Produced Fluid (in Tons) RWC 802 | 1.67 Tons | LANDFILL | 301358 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2747071 | Primary Facility | 2018-06-29 | Routine/Complete Inspection | No Violations Noted | Weather was 70° and sunny at time of inspection. Met with Rockdale Marcellus representative Jim Tracey on location at time of inspection. Rig was in the process of drilling the 12 1/4" hole for the intermediate casing at time of inspection. The surface casing was cemented on 6/25/2018. Reviewed the cement job log and no discrepancies were noted at time of inspection. Rig is anticipating cementing the intermediate casing later this evening. Conducted a walk around inspection of location. No violations noted at time of inspection. |
2750086 | Primary Facility | 2018-07-10 | Drilling/Alteration | No Violations Noted | The weather is 85 Deg. F and sunny at the time of inspection. Routine inspection of Rockdale Marcellus LLC., Harer 713 Pad, well # 2H on July 10, 2018.
Finished drilling and cementing 5-1/2" production string on July 9th at 22:07. Skidding over to the Harer 713 4H well on July 10th. Verified cement PTRs (production string), cement samples and driller's log. Rig is estimating to start drilling on then 4H at approximately midnight. No violations are noted at time of inspection. Wellsite looks neat and well organized. DEP Representative - Ulyana Trynovich, Richard Becher, Oil and Gas Inspectors. Rockdale Marcellus LLC. Representative ¿ Danny Brooks, Wellsite Supervisor. |
2752945 | Primary Facility | 2018-07-16 | Routine/Complete Inspection | No Violations Noted | Weather was 88° and sunny at time of inspection. Met with Rockdale Marcellus representative Danny Brooks on location at time of inspection. Rig has moved off this well and is on the 4H. Reviewed the cement job log from the production cement job and no discrepancies were noted at time of inspection. Conducted a walk around inspection of location. No violations noted at time of inspection. |
2759790 | Primary Facility | 2018-08-01 | Routine/Complete Inspection | No Violations Noted | I met with Levi Lee, Levi Haigler, and Clayton Harriman when I arrived. Crews were deploying containment, regrading, and laying rig mats for the upcoming frac (estimated start 8/6). Some containment appeared to be left from the drilling rig, and I observed some small tears at the berms in this area. The Rockwater 43 K barrel MASS was deployed on the site. I observed that there was only 16-18" of freeboard in the primary tank, and that ~6-8" of rainwater had collected in the secondary tank containment. I informed Levi Lee of the containment berm tears and the freeboard and water in the secondary containment at the tank, and said that he would address them. |
2763056 | Primary Facility | 2018-08-07 | Incident- Response to Accident or Event | No Violations Noted | Spill response inspection; 8/7/2018.
On 8/6/2018, Regina Logue (Rockdale) called at 17:15 to report a possible leak in the containment. The estimated volume of the release was 10 gallons. I entered the site at 08:46 and met with Adam Altieri, Jennifer Compton, and Marc McCartor (all representing Rockdale). Water was ponded immediately south of the containment and field conductivity was greater than 20,000 umhos/cm (photo 2). Rig mats were being removed and cleaned from the area. Diesel-based drilling mud was being cleaned from the containment where rig mats were removed. The drill mud appeared to cover most if not all of the containment area where rig-mats were removed. We walked to the the eastern-most well head (117-21857)and they described the release. It is believed water flowed from the containment surface into the cellar (the cellar was filled with gravel). The containment was not sealed to the cellar, so the water filled the cellar and overtopped. Evidence suggests the produced water flowed from the |
For data sources see[7]