X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-125-24613

Well Details

Well ID: 37-125-24613
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 148479
Farm/Lease Name: HAROLD HAYWOOD WAS 3H
License Status: Active
Spud Date: 2012-03-28
Permit Date: 2011-12-06
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 40.178833
Longitude: -79.976139

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-10-15 2013-10-22 7687 9,281,810.0 410632

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 SP Breaker Halliburton Oxidizing Breaker Sodium Persulfate 7775-27-1 100 0.00007000 0
HAI-OS Halliburton Protects casing Propargyl Alcohol 107-19-7 10 0.00004000 0
Methanol 67-56-1 60 0.00024 0
28% HCl Halliburton Dissolves cement & minerals in perforations Hydrochloric Acid 7647-01-0 28 0.03237 0
BA-40L Halliburton Buffer Potassium carbonate 584-08-7 60 0.00782 0
LP-65 Halliburton Scale Inhibitor Ammonium Chloride 12125-02-9 10 0.00242 0
WG-36 Halliburton Gelling Agent Guar Gum 9000-30-0 100 0.00268 0
FR-66 Halliburton Friction Reducer Hydrotreated light petroleum distillate 64742-47-8 30 0.0272 0
Sand Halliburton Proppant Crystalline Silica 14808-60-7 100 9.9657 0
Water Halliburton Carrier Water 7732-18-5 100 89.7771 0
MC MX 5 Halliburton Nitrate Reducing Bacteria Sodium Nitrate 7631-99-4 60 0.05631 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHESAPEAKE APPALACHIA LLC 286,741.00 46 0.00 0 0.00 0
2014 EQT PROD CO 3,217,488.00 365 0.00 0 0.00 0
2015 EQT PROD CO 2,082,850.00 321 0.00 0 0.00 0
2016 EQT PROD CO 1,960,370.00 358 0.00 0 0.00 0
2017 EQT PROD CO 703,012.00 307 0.00 0 0.00 0
2018 EQT PROD CO 373,151.00 312 0.00 0 0.00 0
2019 EQT PROD CO 146,924.00 85 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2012-S01 Drilling Fluid Waste (in Barrels) 500.00 Bbl INJECTION DISPOSAL WELL 34-167-29395
2012-S01 Drilling Fluid Waste (in Barrels) 10.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012-S02 Produced Fluid (in Barrels) 2,160.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012-S02 Produced Fluid (in Barrels) 1,050.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Drilling Fluid Waste (in Barrels) 108.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Fracing Fluid Waste (in Barrels) 16,784.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Produced Fluid (in Barrels) 1,199.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S01 Produced Fluid (in Barrels) 1,968.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S02 Fracing Fluid Waste (in Barrels) 65.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S02 Produced Fluid (in Barrels) 3,506.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Produced Fluid (in Barrels) 110.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2015-S01 Produced Fluid (in Barrels) 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015-S01 Produced Fluid (in Barrels) 1,969.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Drilling Fluid Waste (in Barrels) 55.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Fracing Fluid Waste (in Barrels) 405.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Produced Fluid (in Barrels) 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015-S02 Produced Fluid (in Barrels) 265.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Produced Fluid (in Barrels) RWC 802 1,000.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016-S01 Produced Fluid (in Barrels) RWC 802 8,985.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S02 Produced Fluid (in Barrels) RWC 802 628.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016-S02 Produced Fluid (in Barrels) RWC 802 130.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2016-S02 Produced Fluid (in Barrels) RWC 802 5,382.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M01 Produced Fluid (in Barrels) RWC 802 133.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-M01 Produced Fluid (in Barrels) RWC 802 195.00 Bbl REUSE (AT WELL PAD)
2017-M02 Produced Fluid (in Barrels) RWC 802 130.00 Bbl REUSE (AT WELL PAD)
2017-M03 Produced Fluid (in Barrels) RWC 802 162.00 Bbl REUSE (AT WELL PAD)
2017-M04 Produced Fluid (in Barrels) RWC 802 195.00 Bbl REUSE (AT WELL PAD)
2017-M05 Produced Fluid (in Barrels) RWC 802 110.00 Bbl REUSE (AT WELL PAD)
2017-M07 Other Oil & Gas Wastes (in Barrels) RWC 899 50.00 Bbl REUSE (AT WELL PAD)
2017-M07 Produced Fluid (in Barrels) RWC 802 110.00 Bbl REUSE (AT WELL PAD)
2017-M07 Produced Fluid (in Barrels) RWC 802 240.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M08 Other Oil & Gas Wastes (in Barrels) RWC 899 100.00 Bbl REUSE (AT WELL PAD)
2017-M08 Produced Fluid (in Barrels) RWC 802 370.00 Bbl REUSE (AT WELL PAD)
2017-M09 Produced Fluid (in Barrels) RWC 802 2,690.00 Bbl REUSE (AT WELL PAD)
2017-M10 Produced Fluid (in Barrels) RWC 802 4.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-M10 Produced Fluid (in Barrels) RWC 802 672.00 Bbl REUSE (AT WELL PAD)
2017-M11 Produced Fluid (in Barrels) RWC 802 65.00 Bbl REUSE (AT WELL PAD)
2017-M12 Produced Fluid (in Barrels) RWC 802 2.10 Bbl INJECTION DISPOSAL WELL 34-031-27177
2017-M12 Produced Fluid (in Barrels) RWC 802 15.19 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-M12 Produced Fluid (in Barrels) RWC 802 35.01 Bbl REUSE (AT WELL PAD)
2018-M01 Other Oil & Gas Wastes (in Barrels) RWC 899 6.67 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018-M01 Produced Fluid (in Barrels) RWC 802 89.84 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M01 Produced Fluid (in Barrels) RWC 802 1.37 Bbl REUSE (AT WELL PAD)
2018-M02 Produced Fluid (in Barrels) RWC 802 2.95 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M02 Produced Fluid (in Barrels) RWC 802 4.13 Bbl REUSE (AT WELL PAD)
2018-M03 Other Oil & Gas Wastes (in Barrels) RWC 899 6.11 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M03 Other Oil & Gas Wastes (in Barrels) RWC 899 5.56 Bbl REUSE (AT WELL PAD)
2018-M03 Produced Fluid (in Barrels) RWC 802 88.72 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M03 Produced Fluid (in Barrels) RWC 802 9.92 Bbl REUSE (AT WELL PAD)
2018-M03 Produced Fluid (in Barrels) RWC 802 0.75 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M04 Other Oil & Gas Wastes (in Barrels) RWC 899 2.86 Bbl REUSE (AT WELL PAD)
2018-M04 Produced Fluid (in Barrels) RWC 802 44.30 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M04 Produced Fluid (in Barrels) RWC 802 46.36 Bbl REUSE (AT WELL PAD)
2018-M05 Other Oil & Gas Wastes (in Barrels) RWC 899 6.19 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M05 Other Oil & Gas Wastes (in Barrels) RWC 899 1.90 Bbl REUSE (AT WELL PAD)
2018-M05 Produced Fluid (in Barrels) RWC 802 1.58 Bbl REUSE (AT WELL PAD)
2018-M06 Other Oil & Gas Wastes (in Barrels) RWC 899 3.81 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M06 Other Oil & Gas Wastes (in Barrels) RWC 899 1.43 Bbl REUSE (AT WELL PAD)
2018-M06 Produced Fluid (in Barrels) RWC 802 9.10 Bbl REUSE (AT WELL PAD)
2018-M07 Other Oil & Gas Wastes (in Barrels) RWC 899 2.38 Bbl REUSE (AT WELL PAD)
2018-M07 Produced Fluid (in Barrels) RWC 802 2.11 Bbl INJECTION DISPOSAL WELL 34-157-25511
2018-M07 Produced Fluid (in Barrels) RWC 802 4.60 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M07 Produced Fluid (in Barrels) RWC 802 2.30 Bbl REUSE (AT WELL PAD)
2018-M08 Other Oil & Gas Wastes (in Barrels) RWC 899 5.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M08 Other Oil & Gas Wastes (in Barrels) RWC 899 0.95 Bbl REUSE (AT WELL PAD)
2018-M08 Produced Fluid (in Barrels) RWC 802 0.48 Bbl INJECTION DISPOSAL WELL 34-157-25511
2018-M08 Produced Fluid (in Barrels) RWC 802 0.48 Bbl REUSE (AT WELL PAD)
2018-M09 Other Oil & Gas Wastes (in Barrels) RWC 899 2.38 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE ORDER 2016-415
2018-M09 Other Oil & Gas Wastes (in Barrels) RWC 899 5.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M09 Other Oil & Gas Wastes (in Barrels) RWC 899 5.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018-M09 Other Oil & Gas Wastes (in Barrels) RWC 899 5.71 Bbl REUSE (AT WELL PAD)
2018-M09 Produced Fluid (in Barrels) RWC 802 0.27 Bbl REUSE (AT WELL PAD)
2018-M10 Other Oil & Gas Wastes (in Barrels) RWC 899 6.19 Bbl REUSE (AT WELL PAD)
2018-M10 Produced Fluid (in Barrels) RWC 802 0.74 Bbl REUSE (AT WELL PAD)
2018-M10 Produced Fluid (in Barrels) RWC 802 3.31 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M11 Other Oil & Gas Wastes (in Barrels) RWC 899 14.05 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M11 Other Oil & Gas Wastes (in Barrels) RWC 899 2.14 Bbl REUSE (AT WELL PAD)
2018-M11 Other Oil & Gas Wastes (in Barrels) RWC 899 0.95 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M11 Produced Fluid (in Barrels) RWC 802 0.54 Bbl REUSE (AT WELL PAD)
2018-M12 Other Oil & Gas Wastes (in Barrels) RWC 899 5.71 Bbl REUSE (AT WELL PAD)
2018-M12 Produced Fluid (in Barrels) RWC 802 2.64 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M12 Produced Fluid (in Barrels) RWC 802 0.65 Bbl REUSE (AT WELL PAD)
2019-M01 Other Oil & Gas Wastes (in Barrels) RWC 899 71.56 Bbl REUSE (AT WELL PAD)
2019-M01 Produced Fluid (in Barrels) RWC 802 264.83 Bbl REUSE (AT WELL PAD)
2019-M02 Other Oil & Gas Wastes (in Barrels) RWC 899 10.48 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019-M02 Other Oil & Gas Wastes (in Barrels) RWC 899 62.38 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Barrels) RWC 802 20.95 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019-M02 Produced Fluid (in Barrels) RWC 802 313.51 Bbl REUSE (AT WELL PAD)
2019-M03 Other Oil & Gas Wastes (in Barrels) RWC 899 184.29 Bbl REUSE (AT WELL PAD)
2019-M03 Produced Fluid (in Barrels) RWC 802 20.93 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019-M03 Produced Fluid (in Barrels) RWC 802 1.92 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019-M03 Produced Fluid (in Barrels) RWC 802 155.59 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2061205 Primary Facility 2012-04-20 Drilling/Alteration No Violations Noted
2063720 Primary Facility 2012-04-26 Drilling/Alteration No Violations Noted
2087836 Primary Facility 2012-07-26 Drilling/Alteration No Violations Noted
2090944 Primary Facility 2012-08-10 Drilling/Alteration No Violations Noted
2312060 Primary Facility 2014-10-08 Complaint Inspection No Violations Noted Drilled and producing. Id sign and e&s ok.
2395338 Primary Facility 2015-07-31 Routine/Complete Inspection No Violations Noted On 7/31/15, I inspected the Harold Haywood site as a routine inspection and made the following observations:
2549493 Primary Facility 2016-12-06 Routine/Partial Inspection No Violations Noted On 12/6/16, I performed a routine partial inspection of the Harold Haywood in response to observed activity on site and made the following observations:

•A drilling rig was being constructed on site at the time of inspection. •A large panel had been set on the pad near the juncture of the pad and access road with a chemical container, multiple metal drums, and multiple pieces of oil covered equipment. A small amount of oil had reached the pad surface. The situation was pointed out to site personnel and was then promptly remediated including removal of all visibly impacted pad material. No violation. •A coil of hose was also found off containment dripping oily material to the pad surface and was promptly removed. No violation.

2552987 Primary Facility 2016-12-16 Follow-up Inspection No Violations Noted On December 16, 2016 I performed a follow up inspection at the Howard Haywood site in response to concerns noted in a previous inspection (ID: 2549486) of the site on 12/6/16 and made the following observations:

•On 12/6/16 multiple issues with containment and minor spills were noted to site personnel and immediately remediated. •Near the junction of the site access road and the pad a large metal plate had been placed so that it was crushing and compromising the containment around multiple pallets of chemicals marked “AES Drilling Fluids”. Multiple other empty chemical storage containers were also found without any containment. This is a violation of 58 Pa. C.S. § 3218.2(d) for failing to provide containment with at least 110% capacity on regulated substances. •A spill of more than ten gallons of antifreeze was found off of containment near the drill rig. The situation was immediately communicated to site personnel for remediation. This constitutes a violation of 25 Pa. Code § 78.57(a) and 25 Pa. Code

2586072 Primary Facility 2017-04-24 Routine/Partial Inspection No Violations Noted On 4/24/17 a RTPT inspection was conducted of the Harold Haywood site. The following was observed.

>Multiple areas along the access road bear sparse or patchy vegetation increasing risk of erosion. No violation, remediation recommended.

>A topsoil pile near the pad entrance is only partially stabilized with straw. No violation, remediation recommended.

> Drilling activity was concluded at the time of inspection and removal of drilling and completion equipment was underway.

> The AST remained on site at time of inspection.

2630930 Primary Facility 2017-07-19 Complaint Inspection No Violations Noted On 7/19/17 an INCDT inspection was conducted related to the Harold Haywood site with regard to complaint ID 328174. The following was observed:

>>In response to a landowner report of sediment impact to their drinking water samples were collected for SAC 946 and bacteriological analysis.

>>The distance from the water supply to the nearest applicable oil & gas activity is roughly 2800 feet. No direct impact from the site was observed.

>>No evidence was observed at the time of inspection to indicate overt surface water impact. The water well head was found to be in good condition.

2688450 Primary Facility 2018-01-30 Routine/Complete Inspection No Violations Noted On 1/30/18 a routine complete of the Haywood Pad was conducted, the following was observed:

>>Substantial equipment was found stored around the site including multiple lifts and vehicles as well as numerous lights, generators, and tanks. An above ground storage tank was found on site as well. Most equipment had adequate secondary containment. Some stored equipment did not, any leaked or spilled fluids would constitute a violation.

>>Wells on site appeared to be in various stages of completion with no rig on site.

2698947 Primary Facility 2017-09-05 Administrative/File Review No Violations Noted On 9/5/17 an administrative inspection related to the Harold Haywood was conducted regarding test results related to complaint ID 328174. No evidence was found in the sample results suggesting impact to the water supply by oil and gas activity.
2722325 Primary Facility 2018-03-27 Complaint Inspection No Violations Noted On 3/27/18 a complaint inspection was conducted in relation to the Harold Haywood Well Site in response to CTS ID: 332966. Sample 3401-071 was collected for chemistry and biological analysis.
2767162 Primary Facility 2018-08-15 Routine/Partial Inspection No Violations Noted On 8/15/18 a routine partial inspection of the Harold Haywood Site was conducted in response to increased activity at the pad. The following was observed:

>>The site was in drilling phase at the time of inspection. High activity was noted on the pad. A drilling rig was active on site at the time of inspection.

>>Multiple containers of contaminated equipment were found off containment resulting in minor impacts to the pad. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents pollution to the ground and Waters of the Commonwealth. Any equipment with the potential to cause pollution including equipment contaminated with petroleum residues should be placed and stored on containment. Runoff from improperly stored equipment will result in violations.

>>Staining found on the pad near the office trailer suspected to be petroleum based (material was hydrophobic and greasy). This constitutes a viola

2790081 Primary Facility 2018-05-01 Administrative/File Review No Violations Noted On 5/1/18 an administrative inspection related to the Haywood site was conducted to analyze results from sample 3401071 related to complaint ID 332966 collected on 3/27/18. Sample analysis found that while the water did not meet state drinking water standards no clear indicators of oil and gas impact were present.
2805663 Primary Facility 2018-11-02 Incident- Response to Accident or Event No Violations Noted On 11/2/18 a complaint inspection of the Harold Haywood well site was conducted in response an operator reported spill. The following was observed:

>>On 10/31/18 an EQT representative reported that 15 gallons of "impaired water" was spilled to the pad.

>>At the time of inspection an operator representative reported that the standing water along the bottom of the AST was found to have very high conductivity during a routine check. The impacted water was pumped out. Field testing of standing water at the time of inspection found water at the site of the initial spill remained impacted with conductivity reading at roughly 1040us. Per the representative the standing water at the time of inspection was believed to be rain water from storms after the initial spill. The impacted water at the time inspection was substantially greater than the 15 gallons initially reported and was in addition to the initial spill. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the opera

2831173 Primary Facility 2019-01-22 Compliance Evaluation No Violations Noted On 1/22/19 a compliance evaluation inspection of the Harold Haywood Well Site was conducted in response to violations recorded on 11/2/18 and 12/16/16. The following was observed:

>>No apparent residual impact related to spill violations from either date were observed. Containment around the AST on site may conceal further impact. No violation.

>>Violations related to non-GPU containment were remediated around time of 12/16/16 inspection and addressed with the operator at the time.

>>GPUs on site continued to lack containment at the time of inspection including on units installed post 10/2016. Violations ongoing.

2845226 Primary Facility 2019-02-19 Routine/Complete Inspection No Violations Noted Well and pad appear to be in good condition. There are 8 flow back tanks on site and 1 large water tank.

Note: Well for this permit #125-24613 tagged as the H1 well. Department records show well # as H3.

For data sources see[7]

References