Well Details

Well ID: 34-029-61347
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Knox Township
Operator Name: WATSON SHAWN D
Well Pad ID:
Farm/Lease Name: ZURBRUGG CE
License Status: Producing
License Date:
Spud Date:
Spud Drilling Contractor:
Final Drill Date: 1909-02-09
Well Total Depth: 674 ft
Configuration: Vertical
Latitude: <Latitude>
Longitude: -81.02116567

For data sources see[1]

Well History

Well Status Well Status Date Comment
Completed 1909-02-09 CHANGED STATUS OF WELL FROM HP TO PR PER TRANSFER FROM HISTORIC OWNER #9998 TO OWNER ON 10/17/2016 CM. UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 12/13/17.
Reached Total Depth 1909-02-09 CHANGED STATUS OF WELL FROM HP TO PR PER TRANSFER FROM HISTORIC OWNER #9998 TO OWNER ON 10/17/2016 CM. UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 12/13/17.
Change of Owner 2016-10-17 Operator changed from 9998, HISTORIC OWNER to 5572, WATSON SHAWN D
Record Last Modified 2019-04-03 CHANGED STATUS OF WELL FROM HP TO PR PER TRANSFER FROM HISTORIC OWNER #9998 TO OWNER ON 10/17/2016 CM. UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 12/13/17.

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2015 WATSON SHAWN D 0 0 0
2016 WATSON SHAWN D 0 0 0
2017 WATSON SHAWN D 0 0 0

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2015 WATSON SHAWN D Brine 0 0
2016 WATSON SHAWN D Brine 0 0
2017 WATSON SHAWN D Brine 0 0

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1142342042 2006-03-13 Production Wells No Violations The well was inspected this date to verify the permit number with the GPS coordinates. The tank battery is shared with twelve other Berea wells and consists of 1-70bbl tank, 1-50 bbl tank and 1-30 bbl tank. There is no identification posted at the wellhead or tank battery, the wells are idle and there is no bond.
1427986956 2015-03-27 Production Wells No Violations I was onsite to conduct a status check with Inspector Kevin Perry. The wellhead is equipped with a shackle line run pumpjack. The well consists of 4.5 casing, 2 tubing and rods. No identification was posted. Well not capable of production.
1522692193 2014-05-08 Orphan No Violations I was on location to perform an orphan inspection. I found during my inspection the well was equipped with a shackle line run pumpjack. The well had a 4.5 casing, 2 tubing and rods. There was no identification signs posted. There was an access point north of the well off of Buck Road; however, the road was over grown with vegetation.
2046489864 2017-05-04 Production Wells Violations Noted The purpose of my inspection was to conduct a status check on well #6--DOGRM. The well was equipped with a straight line pump jack. No shackle lines to operate the well were present. No audible or visual leaks were identified. The tank battery consisted of four (4) steel production tanks. The tanks were empty. The tanks remained in good repair. I did not observe any holes or leaks. Load out valves were closed. Hatch lids were closed. Correct and legible identification shall be posted at the well head and tank battery within 14 days in accordance with 1501:9-9-05 (A)(10). The well was incapable of production. Under 1509.62 (A)(1) the owner of a well that has no reported production for two consecutive reporting periods as reported in accordance with section 1509.11 of the Revised Code shall plug the well in accordance with section 1509.12. Shawn Watson shall submit a written plugging schedule to Inspector Ken Frye at the Ohio Department of Natural Resources, Division of Oil and Gas Resources Management, 3575 Forest Lake Drive, Suite 150, Uniontown, OH 44685, within 30 days, per OAC 1501:9-11-05(B), and plug the well within 180 days. Shawn Watson will be notified if the plugging schedule is approved or denied.
2128693821 2019-01-17 Production Wells No Violations The purpose of my inspection was to follow-up on compliance notice # 2046489864. RBDMS indicated the Owner reported zero production in 2017. The location remained stable. Correct identification was present. No audible or visual leaks were observed. The tank battery consisted of four (4) steel production tanks. The tanks were empty. The tanks remained in good repair. I did not observe any holes or leaks. Load out valves were closed. Hatch lids were closed. I spoke with Shawn Watson on 01/25/2019 regarding the status of plugging the well. He stated that he was working to finance plug and abandonment on the well.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
2046489864 US-OH-120834 2017-07-11 Failure to legibly identify well
2046489864 US-OH-120835 2017-07-11 Well shall be plugged

For data sources see[7]

References