X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-067-21036

Well Details

Well ID: 34-067-21036
Loading map...
Country: United States
State: Ohio
County: Harrison
Municipality: Green Township
Operator Name: STRATA PETROLEUM INC
Well Pad ID:
Farm/Lease Name: WILDLIFE MANAGEMENT
License Status: Plugged and Abandoned
License Date: 2018-01-30
Spud Date: 2008-06-23
Spud Drilling Contractor: G & L DRILLING
Final Drill Date: 2008-06-27
Well Total Depth: 1999 ft
Configuration: Vertical
Latitude: 40.314150257
Longitude: -80.92877163

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-05-28 Proposed Formations:BEREA-DEVONIAN SHALE, Issued Date:5/28/2008, Expired Date:5/28/2009 6:00:00 AM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2008-06-27 UPDATE LOCATION PER DOGRM SURVEYOR 4/16/2018 ALE.
Completion Report Received 2008-12-30 UPDATE LOCATION PER DOGRM SURVEYOR 4/16/2018 ALE.
APP 2018-01-30 Proposed Formations:BEREA, Issued Date:1/30/2018, Expired Date:1/30/2020 12:00:00 PM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2019-01-23 UPDATE LOCATION PER DOGRM SURVEYOR 4/16/2018 ALE.
Record Last Modified 2019-05-13 UPDATE LOCATION PER DOGRM SURVEYOR 4/16/2018 ALE.
Construction Permit Expires 2020-01-30 UPDATE LOCATION PER DOGRM SURVEYOR 4/16/2018 ALE.

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 0 0 OPEN HOLE NATURAL PRODUCTION, NO PERFS; NO RESERVOIR PRESSURE REPORTED

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 STRATA PETROLEUM INC 4642 0 178
2010 STRATA PETROLEUM INC 3963 6 360
2011 STRATA PETROLEUM INC 754 0 120
2012 STRATA PETROLEUM INC 0 0 0
2013 STRATA PETROLEUM INC 0 0 0
2014 STRATA PETROLEUM INC 0 0 0
2015 STRATA PETROLEUM INC 0 0 0
2016 STRATA PETROLEUM INC 0 0 0
2017 STRATA PETROLEUM INC 0 0 0

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 STRATA PETROLEUM INC Brine 0 178
2010 STRATA PETROLEUM INC Brine 0 360
2011 STRATA PETROLEUM INC Brine 0 120
2012 STRATA PETROLEUM INC Brine 0 0
2013 STRATA PETROLEUM INC Brine 0 0
2014 STRATA PETROLEUM INC Brine 0 0
2015 STRATA PETROLEUM INC Brine 0 0
2016 STRATA PETROLEUM INC Brine 0 0
2017 STRATA PETROLEUM INC Brine 0 0

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0101583447 2008-08-05 Completion Testing No Violations Inspection revealed that the drilling pit has been closed . No violations at this time.
0540750421 2008-06-24 Drill / Deepen / Reopen No Violations Inspection revealed that G & L Drilling filled the conductor hole full of cement and are trying to drill the cement at this time. They had a big rock that kept falling into the wellbore so they filled the hole with cement in an attempt to cement the rock in place so they could drill it out.
0558944275 2019-01-23 Plug / Plug Back No Violations Upon my arrival on the snow- covered location, I witnessed the rig loading the vac truck with fresh water. They were stringing out water hoses and cement hoses to set a cement plug in the well. They pumped a 200 foot (37 sks) Class A cement plug from 470 to 270 feet. They displaced cement with 4.8 barrels of fresh water. The rig crew started to pull the 4.5 inch diameter casing out of the well and it would not move. With the approval of ODNR District Supervisor, Mike Moreland, the rig crew shot the 4.5 inch diameter casing off at the depth of 203 feet. This left about 267 feet of 4.5 inch diameter casing in the well. The cement plug should range from 470 feet to 242 feet, with 4.5 inch diameter casing in it. Then there is 39 feet of 4.5 inch diameter casing on top, with no cement in it. The rig crew then pulled the remaining 203 feet of 4.5 inch casing up 3 feet and set another cement plug. They pumped a 200 foot (38 sks), Class A cement plug from 200 feet to ground level. The rig crew pulled 5 joints of 4.5 inch casing out of the well and topped off the well with remaining cement. The crew is going to rig down and move to another well to plug. They will then cut the 7 inch diameter casing off and reclaim both wells at the same time.
0813350554 2013-07-25 Preliminary Restoration No Violations Everything passed according to 1509.072A.
0907710016 2008-07-14 Completion Testing No Violations Inspection revealed that the 4 1/2 casing got hung at app. 750 . The service rig ran tubing and are swabbing thru the tubing at this time. No violations at this time.
0963080467 2008-06-30 Drill / Deepen / Reopen No Violations Inspection revealed that G & L Drilling has TDed the well . Inspectiuon revealed no violations at this time. The crew advised that they didnt run 4 1/2 casing because the well was gasing and the operator didnt want to run casing while the well was gasing. The operator is going to run the production casing with a service rig.
1199592965 2016-11-23 Production Wells No Violations On the day of my inspection I witnessed the permitted well bore is utilizing a pump jack for means of production. The well bore consists of 8.625 inch diameter surface casing, 4.5 inch diameter production casing and 1.5 inch diameter production tubing. At the time of my inspection the pumping unit did not have a prime move in place. All production valves were placed in the open position. Production equipment for the well bore consisted of a 100 barrel production tank and a 2 inch diameter meter run. The meter run showed no indications of recent use. The 100 barrel production tank was placed in an earthen dike that measured approximately 20*20 feet at an average height of 3 feet. RBDMS records indicate that the well has not produced commercially since 2012. I will perform a follow-up inspection to assure that the well is still idle before writing a compliance notice to the well owner.
1219859728 2017-10-31 Production Wells No Violations On the day on my inspection I found this well equipped with a walking beam pumping unit. This inspection is a follow up to compliance notice #2105427973. Well is equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 2.375 inch diameter tubing, and rods. There is no motor on the pumping unit. Tubing valve is open, casing valves are shut. Production equipment includes a 100 barrel steel tank inside of containment. The tank has a bullet hole in the side of it. RBDMS indicates well was last produced in 2011.
1312149262 2019-01-09 Plug / Plug Back No Violations On the day of my inspection I witnessed Unlimited was tripping 2.375 tubing from well. They pulled the rods yesterday and finished tripping tubing during my inspection. Their tally indicates they pulled 1741.55 feet of tubing. They are going to verify it is free of obstructions and trip it back in to set bottom plug tomorrow.
1515510942 2018-01-09 Production Wells No Violations On the day on my inspection I found this well equipped with a walking beam pumping unit. This inspection is a follow up to compliance notice #2105427973. Well is equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 2.375 inch diameter tubing, and rods. There is no motor on the pumping unit. Tubing valve is open, casing valves are shut. Production equipment includes a 100 barrel steel tank inside of containment. The tank has a bullet hole in the side of it. RBDMS indicates well was last produced in 2011. I have been emailing with Mark Obrien who is supposed to be submitting plugging permits for these wells on behalf of the deceased owners wife. His last email dated 1/2/18 says I should receive them this week.
1527015651 2018-05-22 Production Wells No Violations On the day on my inspection I found this well equipped with a walking beam pumping unit. This inspection is a follow up to compliance notice #2105427973. Well is equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 2.375 inch diameter tubing, and rods. There is no motor on the pumping unit. Tubing valve is open, casing valves are shut. Tubing pressure gauge reads 0 psi. Production equipment includes a 100 barrel steel tank inside of containment. The tank has a bullet hole in the side of it. RBDMS indicates well was last produced in 2011. Plugging report expires in January 2020. Email sent to Mark Obrien to see when he plans on having wells plugged. markhobrien@mac.com
1547057835 2019-01-09 Plug / Plug Back No Violations On the day of my inspection I accompanied Jeff Adams. He is covering this plug job for me as I have another plug job ongoing. See his report for further details.
1547061838 2019-01-09 Plug / Plug Back No Violations
1547733815 2019-01-16 Plug / Plug Back No Violations

-680 to 580 feet. They displaced the cement with 9 barrels of fresh water. The rig crew pulled 5 more joints of casing out of the well. This should put at the depth of 470 feet. Shut plug job down for land owner issues.

1557930806 2019-05-13 Plug / Plug Back No Violations On the day of my inspection I witnessed this well has been plugged. Mark Obrien had contacted me in regards to outstanding reclamation on this well. I spoke with Gary Lang, who is contractor responsible for the reclamation, to convey what was needed and that the weather is not conducive for reclamation this week. Currently the wellhead needs cut off and buried. Cement is near surface level. Small pit needs closed and tubing needs removed from site. Minor grading work and everything affected will need seeded. Landowner waiver for lease road will be necessary.
1727747950 2008-06-23 Drill / Deepen / Reopen No Violations Inspection revealed that G & L drilling is reaming the conductor hole at 78 . They are having trouble running the conductor pipe . No violations at this time.
1839196492 2019-01-10 Plug / Plug Back No Violations On the day of my inspection I witnessed unlimited try and pull the 4.5 inch diameter casing. Records indicate there is 970 feet of casing. They pulled 50k and were unable to pull the packer. They worked it up and down for a while. They will shoot it off tomorrow and their final plugs then.
2048903440 2008-06-25 Drill / Deepen / Reopen No Violations In spection revealed that G & L Drilling is trying to run conductor pipe . They are still having trouble running the conductor pipe past the rock that kept falling into the wellbore. No violations at this time.
2105427973 2017-03-15 Production Wells Violations Noted

-11-05(B), and plug the well within 180 days. The owner/operator will be notified if the plugging schedule is approved or denied.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
2105427973 US-OH-121533 2017-04-10 Well shall be plugged

For data sources see[8]