{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.797123717,"lon":-81.58908825,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Noble | |
Municipality: Noble Township | |
Operator Name: NORTHWOOD ENERGY CORP | |
Well Pad ID: | |
Farm/Lease Name: JONES | |
License Status: Producing | |
License Date: 1981-10-30 | |
Spud Date: 1982-01-15 | |
Spud Drilling Contractor: | |
Final Drill Date: 1982-01-22 | |
Well Total Depth: 5666 ft | |
Configuration: Vertical | |
Latitude: 39.797123717 | |
Longitude: -81.58908825 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1981-10-30 | 348 ENERGY PRODUCTION INC GeoDate 10/30/81 |
Oil and Gas | 1981-10-30 | Issued Date 10/30/81 Expired Date 10/30/82 Acres 0000000 Tool Type NT Proposed Formation Proposed Depth 00000 Proposed Drill Depth 00000 |
Original Spud | 1982-01-15 | |
Completed | 1982-01-22 | |
Reached Total Depth | 1982-01-22 | |
Construction Permit Expires | 1982-10-30 | |
CO | 1994-11-25 | 1333 BARR ROBT/dba BIG SKY PET GeoDate 10/30/81 |
Change of Owner | 1998-02-24 | Operator changed from 1333, BARR ROBT/dba BIG SKY PET to 24, ROCANVILLE CORPORATION |
Change of Owner | 2003-06-24 | Operator changed from 24, ROCANVILLE CORPORATION to 4540, PEOPLES PETROLEUM CORP. |
Change of Owner | 2005-07-20 | Operator changed from 4540, PEOPLES PETROLEUM CORP. to 7382, WHITED ROGER |
Change of Owner | 2005-10-04 | Operator changed from 7382, WHITED ROGER to 1634, NORTHWOOD ENERGY CORP |
Record Last Modified | 2015-09-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 2796 | 3434 | 56 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 0 | 2400 Mscf | 30000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | ENERGY PRODUCTION INC | 8093 | 23 | 0 |
1994 | BIG SKY ENERGY INC | 0 | 0 | 365 |
1995 | BIG SKY ENERGY INC | 0 | 0 | 365 |
1996 | BIG SKY ENERGY INC | 0 | 0 | 0 |
1999 | ROCANVILLE CORPORATION | 724 | 0 | 245 |
2000 | ROCANVILLE CORPORATION | 513 | 0 | 334 |
2001 | ROCANVILLE CORPORATION | 625 | 0 | 273 |
2002 | ROCANVILLE CORPORATION | 260 | 0 | 92 |
2003 | WHITED ROGER | 13 | 0 | 61 |
2004 | WHITED ROGER | 847 | 0 | 365 |
2005 | NORTHWOOD ENERGY CORP | 46 | 0 | 365 |
2006 | NORTHWOOD ENERGY CORP | 729 | 0 | 365 |
2007 | NORTHWOOD ENERGY CORP | 554 | 0 | 365 |
2008 | NORTHWOOD ENERGY CORP | 679 | 0 | 365 |
2009 | NORTHWOOD ENERGY CORP | 629 | 0 | 365 |
2010 | NORTHWOOD ENERGY CORP | 732 | 0 | 365 |
2011 | NORTHWOOD ENERGY CORP | 905 | 0 | 0 |
2012 | NORTHWOOD ENERGY CORP | 1009 | 0 | 366 |
2013 | NORTHWOOD ENERGY CORP | 788 | 0 | 365 |
2014 | NORTHWOOD ENERGY CORP | 676 | 0 | 365 |
2015 | NORTHWOOD ENERGY CORP | 624 | 0 | 365 |
2016 | NORTHWOOD ENERGY CORP | 769 | 0 | 365 |
2017 | NORTHWOOD ENERGY CORP | 1695 | 0 | 365 |
2018 | NORTHWOOD ENERGY CORP | 124 | 0 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | ENERGY PRODUCTION INC | Brine | 4 | 0 |
1994 | BIG SKY ENERGY INC | Brine | 0 | 365 |
1995 | BIG SKY ENERGY INC | Brine | 0 | 365 |
1996 | BIG SKY ENERGY INC | Brine | 0 | 0 |
1999 | ROCANVILLE CORPORATION | Brine | 0 | 245 |
2000 | ROCANVILLE CORPORATION | Brine | 0 | 334 |
2001 | ROCANVILLE CORPORATION | Brine | 0 | 273 |
2002 | ROCANVILLE CORPORATION | Brine | 0 | 92 |
2003 | WHITED ROGER | Brine | 0 | 61 |
2004 | WHITED ROGER | Brine | 0 | 365 |
2005 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2006 | NORTHWOOD ENERGY CORP | Brine | 35 | 365 |
2007 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2008 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2009 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2010 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2011 | NORTHWOOD ENERGY CORP | Brine | 0 | |
2012 | NORTHWOOD ENERGY CORP | Brine | 0 | 366 |
2013 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2014 | NORTHWOOD ENERGY CORP | Brine | 8 | 365 |
2015 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2016 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2017 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2018 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000PL7790 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0909014580 | 2017-06-14 | Production Wells | No Violations | The purpose of my inspection was a status check. During my inspection the well was equipped with 8.625 inch diameter surface casing with a casing head, 4.5 inch diameter production casing with a tubing head, 1.5 inch diameter tubing, rods, and a pumping unit powered by an electric motor. Production valves were in the open position and a domestic gas line was attached to the 4.5 inch diameter production casing with an open valve and a Little Joe Regulator. The production equipment consisted of one 50 barrel poly tank, one vertical separator, and a sales meter ran off of a 2 inch diameter line with a chart recorder with chart dated 6/2/17 and .25 inch orifice plate. The identification was located on the 50 barrel tank and the production records were current. |