If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-21367 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.45542903,"lon":-81.51031647,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Cuyahoga | |
Municipality: Beachwood City | |
Operator Name: KLEESE DEVELOPMENT ASSOCIATES | |
Well Pad ID: | |
Farm/Lease Name: CITY OF CLEVELAND | |
License Status: Producing | |
License Date: 1986-03-05 | |
Spud Date: 1986-04-10 | |
Spud Drilling Contractor: B & K DRLG | |
Final Drill Date: 1986-04-17 | |
Well Total Depth: 3840 ft | |
Configuration: Vertical | |
Latitude: <Latitude> | |
Longitude: -81.51031647 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1986-03-05 | 1510 B & K DRILLING CO GeoDate 3/5/86 |
Oil and Gas | 1986-03-05 | Issued Date 3/5/86 Expired Date 3/5/87 Acres 0052708 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03840 Proposed Drill Depth 03840 |
Original Spud | 1986-04-10 | |
Completed | 1986-04-17 | |
Reached Total Depth | 1986-04-17 | |
Construction Permit Expires | 1987-03-05 | |
Completion Report Received | 1987-08-25 | |
CO | 1995-01-30 | 2655 KLEESE DEVELOPMENT ASSOCS GeoDate 3/5/86 |
Correction to Well | 2008-06-27 | UNIT SIZE DECREASED TO 26.817 ACRES. |
Record Last Modified | 2019-06-14 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 3574 | 3652 | 0 |
2006-09-11 | 3593 | 3652 | 17 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 83270 Gal | 50000 | FRAC: H2O,SAND |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0205994084 | 2017-09-15 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated tank battery located on an otherwise undeveloped property. The load-line valves were secure and locked. Tank lids were closed and secure. The secondary containment was intact and dry. I walked the areas surrounding the well and battery and found no signs of impacts or problems. |
1574603434 | 2013-08-23 | UrbanProduction Wells | No Violations | The producing unit consists of the following elements: A production wellhead and aboveground storage tank (AST) battery. The production wellhead is fitted with a mechanical plunger lift system and is located 75 feet east of the tank battery. The tank battery system, which is reportedly shared with the #1 and #8, includes 1 100-barrel production tank, a 50-barrel production tank, and a 50-barrel brine tank, mechanical separator and associated appurtenances. The tank battery is overgrown with weeds. Secondary containment is adequate. Tank and well spacing is in accordance with 1501:09. The interior of the tank battery needs to be cleared of week overgrowth. The API listed on the placard for this well is #3069 which is incorrect. An ID placard with the correct and complete API number is needed. The ID label at the wellhead says Cleveland #3 # 8660, which is incorrect. The wellhead needs a proper ID placard with the correct information. I spoke with Jim Adams, contract pumper for Kleese, about the need for ID and maintenance. He indicated that the issues would be taken care of by the end of the week. |
1788553647 | 2013-02-19 | UrbanProduction Wells | No Violations | The wellhead consists of a mechanical lift unit, not enclosed. The associated tank battery consists of 1 100-barrel (BBL) tank, 2 50 BBL tanks, and a mechanical separator, in a separate, locked enclosure. The spacing is in accordance with the rule. The tank battery dike is adequate. The unit identification is hand written and unclear. I contacted Matt Kleese and advised him about the need for revised identification. The tank battery is shared with the #2054 and #865 units. There has been no production reports filed for this unit since 2010. I contacted Maryann at Kleese Dev. Assoc. She indicated that they may have forgotten to file the 2011 production report. |
For data sources see[9]