X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21610

Well Details

Well ID: 34-035-21610
Loading map...
Country: United States
State: Ohio
County: Cuyahoga
Municipality: Lyndhurst City
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: CITY OF LYNDHURST UNIT
License Status: Producing
License Date: 1996-02-01
Spud Date: 1996-03-28
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]]
Final Drill Date: 1996-04-02
Well Total Depth: 3615 ft
Configuration: Vertical
Latitude: <Latitude>
Longitude: -81.48904929

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1996-02-01 1639 BASS ENERGY CO INC GeoDate 2/1/96
Oil and Gas 1996-02-01 Issued Date 2/1/96 Expired Date 1/31/97 Acres 0020208 Tool Type RTAF Proposed Formation ORSK/NWBG/CLNN Proposed Depth 03615 Proposed Drill Depth 03615
Original Spud 1996-03-28
Completed 1996-04-02
Reached Total Depth 1996-04-02
Completion Report Received 1996-06-07
Construction Permit Expires 1997-01-31
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3408 3420 25
1997-06-29 3385 3457 0
2006-09-11 3454 3457 7
2006-09-11 3423 3432 19

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 150 Gal 0 FRAC W/1500 GAL WATER & 33M# SAND
H2O 0 1500 Gal 33000 & GEL

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1996 BASS ENERGY CO INC 27067 445 122
1997 BASS ENERGY CO INC 52773 256 365
1998 BASS ENERGY CO INC 39250 171 365
1999 BASS ENERGY CO INC 33387 119 365
2000 BASS ENERGY CO INC 26174 227 365
2001 BASS ENERGY CO INC 27119 194 365
2002 BASS ENERGY CO INC 30469 66 365
2003 BASS ENERGY CO INC 22077 164 365
2004 BASS ENERGY CO INC 21926 251 365
2005 BASS ENERGY CO INC 21811 80 365
2006 BASS ENERGY CO INC 15728 91 365
2007 BASS ENERGY CO INC 20271 42 365
2008 BASS ENERGY CO INC 17830 131 365
2009 BASS ENERGY CO INC 17673 96 365
2010 BASS ENERGY CO INC 18849 62 365
2011 BASS ENERGY CO INC 17593 58 0
2012 BASS ENERGY CO INC 17418 52 366
2013 BASS ENERGY CO INC 15641 63 365
2014 BASS ENERGY CO INC 13877 43 365
2015 BASS ENERGY CO INC 11663 0 365
2016 BASS ENERGY CO INC 12189 0 365
2017 BASS ENERGY CO INC 11901 82 365
2018 BASS ENERGY CO INC 11834 56 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1996 BASS ENERGY CO INC Brine 455 122
1997 BASS ENERGY CO INC Brine 557 365
1998 BASS ENERGY CO INC Brine 467 365
1999 BASS ENERGY CO INC Brine 307 365
2000 BASS ENERGY CO INC Brine 259 365
2001 BASS ENERGY CO INC Brine 123 365
2002 BASS ENERGY CO INC Brine 215 365
2003 BASS ENERGY CO INC Brine 149 365
2004 BASS ENERGY CO INC Brine 227 365
2005 BASS ENERGY CO INC Brine 124 365
2006 BASS ENERGY CO INC Brine 118 365
2007 BASS ENERGY CO INC Brine 38 365
2008 BASS ENERGY CO INC Brine 21 365
2009 BASS ENERGY CO INC Brine 118 365
2010 BASS ENERGY CO INC Brine 123 365
2011 BASS ENERGY CO INC Brine 123
2012 BASS ENERGY CO INC Brine 116 366
2013 BASS ENERGY CO INC Brine 148 365
2014 BASS ENERGY CO INC Brine 37 365
2015 BASS ENERGY CO INC Brine 99 365
2016 BASS ENERGY CO INC Brine 54 365
2017 BASS ENERGY CO INC Brine 75 365
2018 BASS ENERGY CO INC Brine 77 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0000018029 Preliminary Restoration No Violations PASSED Y WITNESSED 3/4/97 INSPECTOR NORBERT LOWDER DATE 03/0419/97 DATA FROM OLD VAX INFO
0331654393 2017-05-23 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system located near the municipal pool on Parkview Drive and tank battery is separate board-on-board enclosures located adjacent to the city hall and maintenance buildings. The battery is shared with the #2-1679 well located near the maintenance garage. The load-lines were plugged, locked and secure. The tank lids were closed and sealed. There was secondary containment which was intact with dry interior and free from signs of spills or leakage. Spark arrestor, low-pressure relief valve, and carbon filter were present and well maintained. ID signage was present and complete. Areas around the wellhead were comprise of turf grass lawn. The battery is located at the edge of the driveway and parking area for the maintenance garage. I walked the areas surrounding the wellhead and battery and found no signs of impact or problems.
1030104718 2013-01-14 UrbanProduction Wells No Violations The production unit is comprised of the following elements: a tank battery with 2 140-barrel (BBL) tanks, a mechanical separator, and a wellhead valve assembly. A mechanical plunger lift is affixed to the wellhead valve assembly. The tank battery and the wellhead are enclosed in separate 6-foot enclosures. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-05 . HB 278 safety equipment is present. Unit identification is present and legible at the tank battery. The tank battery secondary containment is adequate. I did not observe any leaks, spills, or other signs of contamination. The gates are locked. The battery is shared with the #1679 Unit.
1218326001 2015-03-04 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well is located on park and community center property owned by the City of Lyndhurst on Parkview Dr. The battery is located behind the City of Lyndhurst Building Department. The wellhead plunger lift system and battery are in separate enclosures. The gates are secure and locked. Connections and fittings are secure and free from signs of leakage or problems. Process safety equipment is present. Load-outs are plugged and secure. Areas around the wellhead and battery are snow-covered at the time of this inspection. The battery is shared with the #2-1610 well which is accessed from Parkview Drive. I did not observe any evidence of impact relating to on-going production activity.
1383112576 2004-07-07 Production Wells No Violations
1797086977 2011-12-22 UrbanProduction Wells No Violations Urban production well inspection/status check. Inspection conducted and well is in compliance with 1501:9-9-05. Well shares a tank battery with 2-1679.
1963756423 2004-08-09 Production Wells No Violations

For data sources see[9]