X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22075

Well Details

Well ID: 34-035-22075
Loading map...
Country: United States
State: Ohio
County: Cuyahoga
Municipality: Gates Mills Village
Operator Name: EOS ENERGY LLC
Well Pad ID:
Farm/Lease Name: MARRA UNIT
License Status: Producing
License Date: 2008-10-03
Spud Date: 2008-11-05
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2008-11-12
Well Total Depth: 3704 ft
Configuration: Vertical
Latitude: <Latitude>
Longitude: -81.39305727

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-10-03 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:10/3/2008, Expired Date:10/3/2009 6:00:00 AM, Drilling unit acres:21.2703, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-11-12
Completion Report Received 2009-09-08
Construction Permit Expires 2009-10-03
Change of Owner 2018-07-31 Operator changed from 1249, CUTTER OIL COMPANY to 10185, EOS ENERGY LLC
Record Last Modified 2018-07-31

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-10-27 3456 3469 38

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 210 Mscf 600 FRAC USED 97,174 GALLONS OF FLUID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 CUTTER OIL COMPANY 0 0 365
2009 CUTTER OIL COMPANY 33090 189 322
2010 CUTTER OIL COMPANY 32499 116 365
2011 CUTTER OIL COMPANY 27558 86 365
2012 CUTTER OIL COMPANY 17887 68 366
2013 CUTTER OIL COMPANY 11994 27 365
2014 CUTTER OIL COMPANY 9483 0 365
2015 CUTTER OIL COMPANY 8056 0 365
2016 CUTTER OIL COMPANY 6678 0 365
2017 CUTTER OIL COMPANY 4972 0 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 CUTTER OIL COMPANY Brine 1260 365
2009 CUTTER OIL COMPANY Brine 672 322
2010 CUTTER OIL COMPANY Brine 210 365
2011 CUTTER OIL COMPANY Brine 235 365
2012 CUTTER OIL COMPANY Brine 232 366
2013 CUTTER OIL COMPANY Brine 130 365
2014 CUTTER OIL COMPANY Brine 124 365
2015 CUTTER OIL COMPANY Brine 148 365
2016 CUTTER OIL COMPANY Brine 96 365
2017 CUTTER OIL COMPANY Brine 65 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0337788681 2008-10-01 Drill / Deepen / Reopen No Violations Location made
0518587004 2018-02-08 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, fittings and connections at the battery were secure and free from leakage or problems. The pump jack system had been removed as part of work-over but the well remained in production. The battery enclosure was locked and secure. The enclosure at the wellhead had been dismantled for work-over. Production reports were current. Proper bonding and insurance was in place. The surrounding areas were covered in several inches of fresh snow cover.
0892362482 2008-11-04 Drill / Deepen / Reopen No Violations making location
1095889042 2011-12-28 UrbanPreliminary Restoration No Violations On 12/28/2012, DNR Inspector Richard Skidmore completed an urban preliminary restoration well inspection for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed.
1231173826 2008-11-05 Completion Testing No Violations Rig move on
1450297545 2015-12-16 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The well and associated battery are located in a densely wooded area on the south side of SR 422 with residential homes beyond. At the time of this inspection, the wellhead and tank battery enclosures were locked and secure. ID signage was present at the head of the lease road, and at both the wellhead and battery locations. Secondary containment was present and intact at both the wellhead and battery. Load-lines were plugged, locked and secure. Fittings and connections were secure with the following exceptions: I observed a minor leak of gas from the top fitting on the domestic meter located in the battery enclosure, and a missing closure wing nut at the production tank hatch lid. I contacted CJ Cutter regarding the gas leakage and missing wing nut. He advised that the items would be addressed within 48 hours.
1477945572 2016-10-31 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. At the time of this inspection, I observed the following: a pump jack unit in a board-on-board enclosure and associated tank battery in a separate board-on-board enclosure. The enclosure gates were locked and secure. Load-line valves were plugged and secure with locks. The electrical panel was locked and secure. Tank lids were closed and secure. The secondary containment was intact and dry with no signs of leakage, spills, or other problems. The areas surrounding the production equipment consisted of trees and wooded areas. I walked the surrounding areas and found no signs of spills, leaks, or other evidence of environmental degradation. During a previous inspection, I had noted that the wing nut was missing from the production tank lid and there was a small gas leak at the domestic meter. These items had been remedied at the time of this inspection.
2097572902 2008-11-06 Drill / Deepen / Reopen No Violations surface cementing

For data sources see[9]

References