Well Details

Well ID: 34-041-20160
Loading map...
Country: United States
State: Ohio
County: Delaware
Municipality: Berkshire Township
Operator Name: HARMAN PATRICIA A
Well Pad ID:
Farm/Lease Name: ALEXANDER BARNEY C
License Status: Active Injection
License Date: 1983-02-11
Spud Date: 1964-10-20
Spud Drilling Contractor: SERVICE RIG
Final Drill Date: 1964-10-31
Well Total Depth: 3010 ft
Configuration: Vertical
Latitude: <Latitude>
Longitude: -82.90288601

For data sources see[1]

Well History

Well Status Well Status Date Comment
Reached Total Depth 1964-10-31 CONVERTED TO SWIW IN 1983 GL=934.10,SWIW I.P. = D & A.
Plugged/Abandoned 1964-11-13 CONVERTED TO SWIW IN 1983 GL=934.10,SWIW I.P. = D & A.
Conversion to Injector 1983-02-11
Salt Water Injection Well 1983-02-11 Issued Date 2/11/83 Expired Date 8/10/83 Acres 0010000 Tool Type CT Proposed Formation GULL RIVER Proposed Depth 03004 Proposed Drill Depth 03004
Storage Well 1983-02-11 Issued Date 2/11/83 Expired Date 8/10/83 Acres 0010000 Tool Type CT Proposed Formation GULL RIVER Proposed Depth 03004 Proposed Drill Depth 03004
Original Spud 1983-03-23 CONVERTED TO SWIW IN 1983 GL=934.10,SWIW I.P. = D & A.
Completed 1983-03-28 CONVERTED TO SWIW IN 1983 GL=934.10,SWIW I.P. = D & A.
CO 1983-05-01 1379 HARMAN CLINTON E GeoDate 2/11/83
Completion Report Received 1983-05-25 CONVERTED TO SWIW IN 1983 GL=934.10,SWIW I.P. = D & A.
Construction Permit Expires 1983-08-10 CONVERTED TO SWIW IN 1983 GL=934.10,SWIW I.P. = D & A.
First Injection 1984-08-07 CONVERTED TO SWIW IN 1983 GL=934.10,SWIW I.P. = D & A.
Annulus Pressure Monitoring Approved 1989-05-31 CONVERTED TO SWIW IN 1983 GL=934.10,SWIW I.P. = D & A.
Last Compliance Report 2007-09-05 CONVERTED TO SWIW IN 1983 GL=934.10,SWIW I.P. = D & A.
Record Last Modified 2017-10-19 CONVERTED TO SWIW IN 1983 GL=934.10,SWIW I.P. = D & A.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-04-28 2937 2947 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 28 150 Gal 0 MUD CAKE ACID

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
001287i775 2002-06-04 Salt Water Injection Well No Violations need 1/4 inch valve on tubing .
0014245604 2004-02-12 Salt Water Injection Well Violations Noted Met Mrs. Harmon (Pat). Husband Clint, passed away in January.This is the first time she has been to the well since. Small drip leak on injection line at 1 1/2 elbow. Plastic bucket placed under it until repaired. Mrs. Harmon will call when repaired. Did
0053895292 2006-02-02 Salt Water Injection Well No Violations Chk well and storage, need to pressure test the annular space. Storage tank at the well head should not be used, it has holes in the side and is not liquid tight.
0147769300 2005-10-20 Salt Water Injection Well Violations Noted FAILURE TO SUBMIT ANNUAL SALTWATER INJECTION WELL REPORTS
0150238378 2016-03-22 Administrative Inspection No Violations Met with Bill Jackson and Pat Harman regarding actions required to meet compliance standards. A Mechanical Integrity Test is required and a flow test to evaluate the capability of the well. The operator stated this will be scheduled. If the well is capable the flow line, tank, and dike with synthetic liner will be installed. Otherwise the well shall be plugged.
0249418827 2015-07-01 Salt Water Injection Well No Violations Inspected the Alexander #1 (SWIW #6) as part of a standard injection well status check. Inspect well, pressures, storage and identification. Status: no change in status from previous inspection.
0280837669 2015-08-05 Salt Water Injection Well Violations Noted Inspect well and tank location. The tubing valve for the 0.25 inch test port is inoperable. The brine storage tank integrity has been compromised and is required to be replaced. The operator is advised when the tank is replaced the dike area will require reconstruction to current standards with an Impermeable liner. The flow line has been compromised and will require replacement and testing. The well has been idle for several years.

OAC 1501:9-3-07(K) Any well which is or becomes incapable of injecting fluids shall be plugged in accordance with sections 1509.13 and 1509.15 of the Revised Code unless written permission is granted by the chief. If the chief finds that a well should be plugged, the chief shall notify the injection well owner to that effect by order, in writing, and shall specify in such order a reasonable time within which to comply. No injection well owner shall fail or refuse to plug a well within the time specified in the order. Each day on which such a well remains unplugged thereafter constitutes a separate offense.

0281644619 2007-08-22 Salt Water Injection Well No Violations Chk. Well and storage, new tank installed and all new fittings. New valves on well head, new injection line and filtration the well needs to have an MIT before starting to inject water. Valves on well and at the tank are closed at this time. Called Mrs Hrmond at approx. 1:50 PM talked about the pressure test and other miner leaks at the production site.
0302024459 2017-02-28 Salt Water Injection Well No Violations Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 2nd, 3rd, & 4th quarters of 2016. Please submit the appropriate reports by March 14, 2017. Reports received 5/30/2017
0309855158 2018-02-12 Salt Water Injection Well No Violations Inspect well for integrity and pressure. A compliance notice was issued August 5, 2015 for plugging required of well. Well is shut in and incapable of injection. The integrity of the storage tank has failed.
0460153209 2008-01-18 Salt Water Injection Well No Violations Chk well and storage, Ok.
0527991106 2018-08-21 Salt Water Injection Well No Violations Inspect well for integrity and pressure. A compliance notice was issued August 5, 2015 for plugging required of well. Well is shut in and incapable of injection. The integrity of the storage tank has failed. The surface casing valve is leaking gas at the well head.
0598008255 2015-12-09 Salt Water Injection Well No Violations Inspected the Alexander #1 (SWIW#6) as part of a standard compliance notice follow up. Status: no corrective action taken, non-compliant.
0605781590 2017-07-11 Salt Water Injection Well No Violations Inspect well for integrity and pressure. A compliance notice was issued August 5, 2015 for plugging required of well. Well is shut in and incapable of injection. The integrity of the storage tank has failed.
0626124023 2016-07-14 Salt Water Injection Well No Violations Inspect well for integrity and pressure. The well is shut in. The back side annulus has 160 psi natural gas.
0641266978 2017-01-31 Salt Water Injection Well No Violations Inspect well for integrity and pressure. An evaluation of this well indicates the annulus pressure is artificially enhanced by the gas pressure present on the eight inch casing. The most recent MIT was conducted on 3/31/2016. There is an openCompliance notice to plug well on 8/5/2015.
0669504156 2016-01-25 Salt Water Injection Well No Violations Inspect well for integrity and pressure. Well is shut in and no activity has occurred at the well head since last inspection.
0697622056 2009-03-19 Salt Water Injection Well No Violations Chk well and storage.
0707073089 2006-12-01 Salt Water Injection Well No Violations Storage tank at the well head has been removed. Injection line unhooked, well not in use.
0727947090 2016-03-16 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2015, despite a letter that was sent March 1, 2016 with a deadline of March 15, 2016 to submit the reports requested. Reports received.
0757029621 2010-03-30 Salt Water Injection Well No Violations Chk well and storage, ok.
0766765191 2014-10-07 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15, 2013. The Disposal Fee report for the 3rd and 4th Quarter of 2013 needs to be filed also.
0783864130 2011-06-06 Production Wells No Violations accompanied B.Bear on status check of SWIW well.
0828685381 2015-10-19 Salt Water Injection Well No Violations Inspected the Alexander #1 (SWIW #6) as part of a standard injection well status check. Check well, pressures, storage and identification. Status: no change in status from previous inspection.
0905257822 2017-04-18 Salt Water Injection Well No Violations Inspect well for integrity and pressure. A compliance notice was issued August 5, 2015 for plugging required of well. Well is shut in and incapable of injection. The integrity of the storage tank has failed. The backside annulus has 170 psi of gas pressure.
1032556554 2013-12-18 Salt Water Injection Well No Violations Inspected the Alexander #1 (SWIW #6) as part of a standard injection well status check. Check well, pressures, storage and identification. No change in status from previous inspection..
1035111681 2018-02-16 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 1st, 2nd, 3rd, & 4th quarter of 2017 . Please submit the appropriate reports by March 17, 2018.
1049170052 2016-04-05 Salt Water Injection Well No Violations Inspect well for integrity and pressure. The 8-5/8 inch well head annular is loaded with shallow natural gas at a measured pressure of 180 PSI.
1053006842 2003-05-15 Salt Water Injection Well No Violations Well on gravity.
1057681019 2003-07-08 Salt Water Injection Well No Violations Injection done on gravity. ID, dikes ok.
1074569511 2011-05-10 Salt Water Injection Well No Violations Check well and storage, Ok. Valves on the well head are closed at this time.
1078763489 2004-03-08 Salt Water Injection Well No Violations Plumbing leak at well on elbow has been replaced and repaired.

Well is gravity pressure over 125 on annulus.

1099057347 2004-10-29 Salt Water Injection Well No Violations Chk well and storage, Ok.
1109706002 2005-03-01 Salt Water Injection Well No Violations Snow cover and snowing. Facility appears ok. Well takes fluid on gravity.
1115493886 2003-01-30 Salt Water Injection Well No Violations Weather: snow covered 25F 9:30 a.m. Inspection w/ Jeff Fry. Integrity of well checked ok. ID was present. Fluid is taken on gravity.
1132915555 2016-04-27 Salt Water Injection Well No Violations Inspect well, test pressures on well. The 4.5 inch to 8.625 inch annulus has 150 psi of gas pressure. The 2.375 inch to 4.5 inch annulus has 120 psi of pressure. The tubing initially had a vacuum and within a minute was bled down to zero. Bill Jackson was not available when attempted to make contact.
1162627257 2015-07-16 Salt Water Injection Well No Violations Check dike water for chloride content: 28 ppm.
1187355800 2007-08-17 Salt Water Injection Well No Violations Chk well and stoage, Storage tank has been removed and the injection line has been unhooked from the well head. The well is incapable of being used for injection at this time. Approx 9:15 AM I talked to Mrs. Harmon and she told me the landowner has her in court over the well and that he is planing on having Jack Fishburne work the well over and set a new tank so that the well can be used.
1188225343 2007-08-27 Salt Water Injection Well No Violations On site for MIT. Pressured up to 300 psi, lost 5psi in 15 min, Past test. New tank of the same size has been installed. New well head fittings and injection line installed, quarter inch tap and a new gage on well head. Identification painted on the storage tank.
1192058254 2013-05-07 Salt Water Injection Well No Violations Inspect injection well, storage and identification. All valves shut, well shut-in. Currently testing feasibility of placing back online.
1194011892 2007-11-02 Salt Water Injection Well No Violations Chk well and storage,Ok.
1205246539 2008-03-11 Salt Water Injection Well No Violations Chk well and storage, on my last inspection of 01/18/08 I found that the storage tank needs a lid on the larger opening to prevent some one form falling into the tank. I phoned and told Mrs Harmon ot the problem and requested that a cover be put over the opening. As of this date the lid has not been installed as requested.
1205766719 Salt Water Injection Well No Violations
1227225240 2016-03-02 Salt Water Injection Well No Violations Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 2nd, 3rd & 4th quarter of 2015 despite a letter that was sent with a deadline of February 29, 2016. Please submit the appropriate reports by March 16th, 2016. fee report received
1231768499 2018-05-03 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the 2017 Salt Water Injection Well Annual Report (Form 204) that was due to the Division by April 15, 2018. Please submit the requested report by June 4, 2018. reports received 7/7/18
1247147848 2009-07-09 Salt Water Injection Well No Violations Chk well and storage. Valves on well head closed. Vertical tank at storage site has the clean out hatch off of it.
1255456001 2009-10-13 Salt Water Injection Well No Violations Chk well and storage, Ok. Valves on tubing closed at the well head.
1268115589 2012-02-29 Salt Water Injection Well No Violations Inspect Well. Well shut in. Operator needs to service well and clean out.
1295126811 2016-10-05 Salt Water Injection Well No Violations Inspect well for integrity and pressure. The well is shut in. The wellhead gas zone has 160 psi.
1323268510 2011-12-07 Salt Water Injection Well No Violations An inspection revealed no violations. No injection at time of the inspection. A fitting has been installed on the injection side of well.
1345641434 2012-08-22 Salt Water Injection Well No Violations Inspected the Alexander #1 (SWIW #6) as part of a standard quarterly status check. Well is shut-in, back-side annulus pressure 120 psi. The well identification is clearly marked on the storage tank, the well is located inside the dike. Location entry is not marked well and is located at 1426 south galena road.
1351000233 2012-10-21 Salt Water Injection Well No Violations Inspected the Alaxander #1 (#160) (SWIW #6) as part of a standard injection well status check. Injection: shut-in, annulus: 125 pounds per square inch. Well identification and site OK.
1363783062 2013-03-20 Salt Water Injection Well No Violations Inspect injection well for dike and tank measurements. Dike 36L x 25W x 2D. Tank 21 x 8 horizontal. (188 barrels at 100% capacity).
1364402602 2013-03-26 Salt Water Injection Well No Violations Received a forwarded email dated 3/26/2013 from Ms. Betsy Bender 1426 S. Galena Rd. regarding the flow line to the Alexander #1 (#160) (SWIW #6) which had parted. Contacted Ms. Bender 3/26/13 and discussed her concern that the line is broken and it may have caused a leak. Explained to her that the well is not in use and the line is shut-in on both sides (injection well and production well). Inspected the well on 3/26/13 and found the line had separated at a line slice (hose clamp came loose). No release occurred. Called Mr. Harry Kallipolitis of the Ohio EPA and informed him of the findings. Informed Inspector Tom Benko (UIC) of the findings and he met with the operator on location 3/27/13. Status: ok.
1364563310 2013-03-27 Salt Water Injection Well No Violations Inspect well, tanks and flow line with Bill Jackson, well tender. An Email message has been received identifying a broken flow line. During the inspection and site meeting it was reported the flow line previously broke due to a fallen tree with an oversized root ball. This break was repaired with a plumbers fitting and hose clamps. This splice was parted during the inspection. Inspection of the line revealed a total of three historic mechanical splices in the valley. No fluids were released from the flow line as the well has not been in production for an extended period of time. A previous repair the line is present near the production tanks, a new section of line was welded in place for this repair and is not of concern to this issue. The well and flow line have been shut in for several years and have not been utilized. During This inspection and previous inspections the operator reported that the well required servicing. The operator shall either repair the line, under the supervision of DNR inspectors, then pressure test the line, and put the well into production. Notification of the inspector is required prior to injecting fluids into the well. Or, remove the line and plug the injection well. The operator is being notified that a resolution is required within 60 days of this inspection report.
1385130763 2013-11-21 Salt Water Injection Well No Violations Inspected the Alexander #1 (SWIW #6) as part of a standard injection well status check. Check well, pressures, storage and identification. Status: well is not in operation.
1389993309 2014-01-17 Salt Water Injection Well No Violations Inspected the Alexander #1 (SWIW #6) as part of a standard injection well status check. Check well, pressures, storage and identification. No change in status from previous inspection.
1390920086 2014-01-28 Salt Water Injection Well No Violations Location Information. ENTRANCE: Lat. 40.23727 Long. -82.89856 / WELL HEAD: Lat. 40.23731 Long. -82 .90269 / CENTER-OF-STORAGE: Lat. 40.23729 Long. -82.90266. NOTE: the well head is located inside the storage dike.
1394803872 2014-03-14 Salt Water Injection Well No Violations Inspected the Alexander #1 (SWIW #6) as part of a standard injection well status check. Inspect well, pressures, storage and identification. Status: no change in status from previous inspection.
1400352709 2018-05-30 Salt Water Injection Well No Violations Inspect well for casing pressures. The well is incapable of operation and shut in. The tubing has about 5 pounds per square inch (PSI), the annulus has 145 psi, and the surface casing has 150 psi.
1407441478 2014-08-08 Salt Water Injection Well No Violations Inspect well for integrity and check pressures. Well is shut in. Storage tank is empty. Tank bottom is rusted near the inlet valve. The tank will need to be replaced or repaired prior to injection start up. The Flow line from the production well to the injection storage tank has not been replaced and is shut in.
1408711772 2014-08-22 Salt Water Injection Well No Violations Inspected the Alexander #1 (SWIW #6) as part of a standard injection well status check. Inspect well, pressures, storage and identification. Status: No change in status from previous inspection.
1414419743 2014-10-27 Salt Water Injection Well No Violations Provided Reports requested. Compliance Notice satisfied.
1415129240 2014-11-04 Salt Water Injection Well No Violations Inspect well for integrity and pressure. Well is shut in. Met with Bill Jackson on location. Storage tank at well head has rusted through along weld at base of tank. The flow line from the production line to the brine storage tank needs to be replaced.
1426076701 2015-03-10 Salt Water Injection Well No Violations Inspected the Alexander #1 (SWIW #6) as part of a standard injection well status check. Inspect well, pressures, storage and identification. Status: no change in status from previous inspection.
1436798832 2015-07-01 Salt Water Injection Well No Violations Inspected the Alexander #1 (SWIW #6) as part of a standard injection well status check. Inspect well, pressures, storage and identification. Status: no change in status from previous inspection.
1450119292 2009-12-16 Salt Water Injection Well No Violations Check well and storage, Ok. Vaves on well head are closed.
1458234349 2016-03-09 Salt Water Injection Well No Violations Inspect well. Well is shut in. No repair activity has occurred on the well or location. Compliance Order was issued on 8/5/2015, the remedy date for repairs was 2/1/2016.
1459516486 2016-03-31 Salt Water Injection Well No Violations Conducted Mechanical Integrity Test and Infectivity test on well. The Annulus had 150 pounds of pressure prior to initiating this Mechanical Integrity Test. The annulus pressure was released to zero before being filled with water and pressure testing the well. The back side of the 4.5 inch casing has natural gas from the Clinton Formation. This pressure was released to zero pressure prior to initiating the MIT test. The annulus was loaded with 3.5 to 4 barrels of water then pressure up to 328 psi. The pressure was monitored for fifteen minutes with a pressure loss of less than 1 percent at 325 psi. The MIT passed the requirements of the testing procedures. The tubing was tested for infectivity. The specifications for the 2-3/ EUE injection tubing requires about 11 barrels of water to fill the pipe where the packer is set. Fresh water with soap was heated to 180 degrees and pumped into the tubing. Approximately 5 bbl of water was pumped into the tubing when the tubing began to pressure up to about 400 psi. Pumping was terminated and the job was shut down. The well did not take any additional fluids. The tubing on this well is plugged. The tubing and packer need to be removed and inspected. If this well is going to be put back into production the operator is recommended to install a new packer and tubing. This well is currently incapable of production.
1523915151 2010-08-02 Salt Water Injection Well No Violations check well and storage, Ok.
1524841916 2018-04-16 Salt Water Injection Well No Violations Inspect well for integrity and pressure. A compliance notice was issued August 5, 2015 for plugging required of well. Well is shut in and incapable of injection. The integrity of the storage tank has failed. The surface casing valve is leaking gas at the well head.
1564449701 2018-10-11 Salt Water Injection Well No Violations Inspect well for integrity and pressure. A compliance notice was issued August 5, 2015 for plugging required of well. Well is shut in and incapable of injection. The integrity of the storage tank has failed. The surface facility required upgrading to current standards.
1578036407 2008-09-04 Salt Water Injection Well No Violations Chk well and storge, Ok.
1623185780 2015-11-03 Salt Water Injection Well No Violations Inspect well for integrity and pressure. The well is shut in. No contact by operator to replace tanks, lines, or repair well.
1624504102 2014-04-03 Salt Water Injection Well No Violations Inspect location with NW Regional Supervisor, William Ziegler.
1656724318 2006-05-19 Salt Water Injection Well No Violations Chk well and storage, Valve on the annulus is leaking and I can not chk the pressure. It has possitive pressure but has not been tested for some time. A pressure tset should be scheduled soon. The tank at the well head is full of holes and should be emptied and removed.
1686462050 2011-06-06 Salt Water Injection Well No Violations Accompanied Brent Bear and Josh Garland on inspection.
1743075808 2013-08-21 Salt Water Injection Well No Violations Inspected the Alexander #1 (SWIW #6) as part of a standard injection well status check. Check well, storage and identification. The injection well remains out of service.
1783692970 2016-03-15 Salt Water Injection Well No Violations Inspect well with Bill Jackson who represents the operator. The well is required to have an Mechanical Integrity Test (MIT) conducted on the annular space of the well. The operator is advised to evaluate and conduct an injection rate test of this well to determine if the well is capable of fluid injection. If this is not sufficient the operator is advised to service the well by releasing the packer and pulling the tubing for evaluation, or the well shall be plugged. The fittings for the 8-5/8 inch well head are leaking natural gas and require replacement. Upon replacement of these parts a 1/4 fitting for a pressure gauge shall be installed. If this well passed the MIT test and is capable of fluid injection at a satisfactory rate the operator is required to perform the following site upgrades. The operator will be required to submit the UIC section for approval a design plan for a replacement storage dike that meets the current standards. Upon approval of the surface facility storage design plan construction can occur. The existing storage tank will be removed from service. The storage area shall consist of a containment area sufficient to hold the capacity for a replacement storage tank with a synthetic liner. The flow line from the production well tank to the injections well storage tank shall be replaced with new UV resistant pipe.
1795619021 2004-05-26 Salt Water Injection Well No Violations GPS updated. No activity at disposal site.
1831314502 2009-02-20 Salt Water Injection Well No Violations Chk well and storage, Ok.

Light snow cover.

1833493327 2012-05-21 Salt Water Injection Well No Violations Inspect Well. Shut in.
1843020609 2011-09-21 Salt Water Injection Well No Violations An inspection revealed no violations at this time. Unable to obtain injection pressure at this time, as there is no fitting available for gauge installation. Notified Mr. Bill Jackson, the representative for Patricia Harman to install 1/4 fitting on injection side. This location was tagged with ribbon for him to also reference. Note: Saltwater line from Permit 129 to this location had released brine and line has since been fused together and cleanup is ongoing. Please refer to Inspect Reports under Permit 129 for more details.
1915680927 2006-12-14 Salt Water Injection Well No Violations Inspected well with Jeff Fry. There was no ID posted at the tank battery or the wellhead. There was no quarter inch tap on the injection, however it was determined that there was 0 psi. It was determined that there was positive pressure on the annulus.
1971798664 2008-12-12 Salt Water Injection Well No Violations Check well and storage, Ok.
1977319963 2014-05-29 Salt Water Injection Well No Violations Inspected the Alexander #1 (SWIW #160) as part of a standard injection well status check. Inspect well, pressures, storage and identification. Status: no change in status from previous inspection.
1979080600 2007-02-06 Salt Water Injection Well No Violations There was no ID posted at the tank battery or the wellhead. There was no quarter inch tap on the injection, however it was determined that there was 0 psi. It was determined that there was positive pressure on the annulus. I talked with the pumper Bob Bell. He indicated that the injection well is currently not in production and wont be until the spring when they plan to bring in a new tank.
2020863809 2011-06-06 Salt Water Injection Well No Violations An inspection revealed no violations at this time. No injection at time of inspection.
2023932252 2017-05-15 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on April 15th for 2016, despite a letter that was sent April 28, 2017 with a deadline of May 12, 2017 to submit the reports requested. please submit the requested Forms to the Division by 5/26/2017. Reports Received 5/26/2017
2024476874 2019-02-11 Salt Water Injection Well Violations Noted The Division has not received the 1st, 2nd, 3rd, & 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019.
2043322253 2013-02-28 Salt Water Injection Well No Violations Standard injection well status check, well is currently not being used for injection. Site, storage, identification ok.
2089007205 2017-10-25 Salt Water Injection Well No Violations Inspect well for integrity and pressure. A compliance notice was issued August 5, 2015 for plugging required of well. Well is shut in and incapable of injection. The integrity of the storage tank has failed.
2092321176 2006-06-22 Salt Water Injection Well No Violations On site for routine inspection. The annulus has not been pressure tested for some time the well head fittings( i.e.: valves) will not allow for monitoring of the pressure due to deteriorated conditions.

A pressure test w/an inspector on the site should be arranged.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0014245604 US-OH-112373 2004-02-17 Pollution/Contamination
0147769300 US-OH-113663 2005-10-20 Failure to monitor pressures/volumes
0280837669 US-OH-122918 2015-08-31 Violation of injection tubing/fitting requirements
0280837669 US-OH-122919 2015-08-31 Well shall be plugged
0727947090 US-OH-128296 2016-05-06 Failure to file salt water injection annual report
0766765191 US-OH-128715 2014-10-31 Failure to file salt water injection annual report
1035111681 US-OH-100512 2018-02-23 Failure to report disposal fees
1231768499 US-OH-106237 2019-04-08 9-3-04B Failure to file salt water injection annual report
2023932252 US-OH-120565 2017-06-29 9-3-04B Failure to file salt water injection annual report
2024476874 US-OH-120576 2019-04-08 NONE Failure to report disposal fees