34-043-20127

Well Details

Well ID: 34-043-20127
Loading map...
Country: United States
State: Ohio
County: Erie
Municipality: Berlin Township
Operator Name: EMERGENCY PLUGGING
Well Pad ID:
Farm/Lease Name: SOVIAK PAUL (WM & MILDRED)
License Status: Final Restoration
License Date: 2008-09-18
Spud Date: 1987-01-19
Spud Drilling Contractor: BOB HUWER DRLG
Final Drill Date: 1987-01-22
Well Total Depth: 798 ft
Configuration: Vertical
Latitude: <Latitude>
Longitude: -82.45301212

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1986-01-22 Issued Date 1/22/86 Expired Date 1/22/87 Acres 0010000 Tool Type RTAF Proposed Formation SYLVANIA Proposed Depth 00798 Proposed Drill Depth 00798
Original Spud 1987-01-19 FIELD REVIEW REQUEST TO INSPECTOR FOR ORPHAN WELL REFERRAL 9/15/03; I&O CASE # 2004 08 072;
Completed 1987-01-22 FIELD REVIEW REQUEST TO INSPECTOR FOR ORPHAN WELL REFERRAL 9/15/03; I&O CASE # 2004 08 072;
Reached Total Depth 1987-01-22 FIELD REVIEW REQUEST TO INSPECTOR FOR ORPHAN WELL REFERRAL 9/15/03; I&O CASE # 2004 08 072;
CO 1987-06-01 1452 BUCKEYE PETROL CORP INC GeoDate 1/22/86
Completion Report Received 1988-04-20 FIELD REVIEW REQUEST TO INSPECTOR FOR ORPHAN WELL REFERRAL 9/15/03; I&O CASE # 2004 08 072;
Plugged by Orphan Well Program 2008-09-11 Plugged by Orphan Well Program
Plugged/Abandoned 2008-09-11 FIELD REVIEW REQUEST TO INSPECTOR FOR ORPHAN WELL REFERRAL 9/15/03; I&O CASE # 2004 08 072;
Change of Owner 2008-09-16 Operator changed from 1452, BUCKEYE PETROL CORP INC to 8318, ORPHAN WELL PROGRAM
APP 2008-09-18 Proposed Formations:SYLVANIA, Issued Date:9/18/2008, Expired Date:9/18/2009 6:00:00 AM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:
Construction Permit Expires 2009-09-18 FIELD REVIEW REQUEST TO INSPECTOR FOR ORPHAN WELL REFERRAL 9/15/03; I&O CASE # 2004 08 072;
Record Last Modified 2017-02-15 FIELD REVIEW REQUEST TO INSPECTOR FOR ORPHAN WELL REFERRAL 9/15/03; I&O CASE # 2004 08 072;

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 730 748 0
2006-09-11 740 750 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 1000 Gal 0 ACID

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0322071813 2008-09-10 Plug / Plug Back No Violations Attempt to plug well. Mark with Formation Cementing on site. Ron Gibson on site to conduct plugging activity. Attempt to kill well with 14 bbl fresh water. Begin pulling tubing. Well blew out with 5 joints of pipe still in hole. Kill well with water on site. Attempt to run tubing to bottom of well and displace cement into well. Well blew out uncontrolled second time when adding joint of tubing. Reinstall well head to control well. Obtain load of 9.9 lb brine, and pump away 60 bbl. Well takes about 1 bbl per minute. Stop plugging activity until well head diverter is installed.
0346851036 2008-07-31 Orphan No Violations The property the well is located on has been sold within the last 2 years. New landowner requested to complete orphan right to entry application. Well is leaking gas at slips. Neighbor at adjacent home reports H2S odors.
0484629439 2003-03-19 Production Wells No Violations Well head is present. Valves closed and rusted in. Well is incapable of production. A separator is located at the edge of the field. N41.29468 & W82.45311.
0778927771 2008-02-25 Orphan No Violations Inspect well. Casing in poor condition. Slight H2S odor.
1218119824 2008-08-07 Orphan No Violations Inspect well at request of adjacent landowner with complaints of odors and feeling sick. Gas well is leaking from steel plates at top of slips. 4.5 inch longstring and 2 inch tubing. Recommend well be plugged as emergency contract. Gas readings at well head were at 82. Breezy conditions during inspection did not allow for reading beyond the well. The Barclay residence is located 587 feet to the Northwest of the well. The Mr. Barclay has indicated that he is experiencing significantly more headaches. Separator and existing oil field debris exist near the well.
1500127059 2008-08-11 Plug / Plug Back No Violations Meet with contractors for bidding on emergency plug of well.
1622380844 2008-09-25 Final Restoration No Violations Inspect location for final restoration. Site ok.
1777358880 2008-09-11 Plug / Plug Back No Violations Well plugging activities. Install swab rubber well head. Six joints of pipe are still in hole. Pump 9.9 lb brine into well during activity. With Well head control in place, pull tubing out of well. Well is controlled and blowout is prevented. Bull head 60 sacks of class A cement with accelerator, cellophane and hulls. Well full with cement, and falls away about 200 feet. Additional 5 sacks cement mixed and pumped into well. Swage installed on well head.
1971972024 2003-11-04 Orphan No Violations Inspect Well. 4 casing, slips, 1.5 tubing, Production lines and separation unit are in place. Well head rusted and in poor condition. Valves frozen.
2086702709 2008-09-08 Plug / Plug Back No Violations Ron Gibson Begins plugging operations. Well at 240 psi, begin blow down well. After about 2 hours well still has 100 psi. Monitor for H2S and LEL. Highest reading of 11 ppm H2S about 200 feet from well when back side of well opened and blown down. The decision was made to wait until the cement pump truck was on site to kill well on the following day. The equipment on site was not capable of overcoming the well conditions.

For data sources see[5]