34-075-22298

Well Details

Well ID: 34-075-22298
Loading map...
Country: United States
State: Ohio
County: Holmes
Municipality: Washington Township
Operator Name: HARLEY DRILLING & PRODUCING LT
Well Pad ID:
Farm/Lease Name: KICK ETAL
License Status: Producing
License Date: 1980-07-09
Spud Date: 1980-06-30
Spud Drilling Contractor:
Final Drill Date: 1990-08-09
Well Total Depth: 2958 ft
Configuration: Vertical
Latitude: 40.639849360
Longitude: -82.19048188

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1980-06-30 R.I. 7-3-80
CO 1980-07-09 1837 RUFFNER PETROLEUM CORP GeoDate 7/9/80
Completed 1990-08-09 R.I. 7-3-80
Reached Total Depth 1990-08-09 R.I. 7-3-80
CO 1992-06-10 121 HORTIN & HUFFMAN PET GEOL GeoDate 7/9/80
Change of Owner 2000-03-06 Operator changed from 121, HORTIN & HUFFMAN PET GEOL to 337, HARLEY DRILLING & PRODUCI
Record Last Modified 2019-06-04 R.I. 7-3-80

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 2941 2976 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 45000 Gal 25000 PF(LEA.@).

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1983 HORTIN & HUFFMAN PET GEOL 1639 5 365
1984 HORTIN & HUFFMAN PET GEOL 0 0 0
1985 HORTIN & HUFFMAN PET GEOL 1084 0 365
1986 HORTIN & HUFFMAN PET GEOL 1445 0 365
1988 ENOLD WALTER (COEN) 2422 0 305
1989 RUFFNER PETROLEUM CORP 1352 0 338
1990 RUFFNER PETROLEUM CORP 1030 41 365
1991 RUFFNER PETROLEUM CORP 1574 0 365
1992 HORTIN & HUFFMAN PET GEOL 419 0 120
1993 HORTIN & HUFFMAN PET GEOL 1860 0 365
1994 HORTIN & HUFFMAN PET GEOL 1997 0 310
1995 HORTIN & HUFFMAN PET GEOL 1730 0 305
1996 HORTIN & HUFFMAN PET GEOL 1534 0 0
1997 HORTIN & HUFFMAN PET GEOL 1502 0 360
1998 HORTIN & HUFFMAN PET GEOL 1270 0 360
1999 HORTIN & HUFFMAN PET GEOL 1412 0 365
2000 HARLEY DRILLING & PRODUCING LT 2153 0 365
2001 HARLEY DRILLING & PRODUCING LT 2310 0 365
2002 HARLEY DRILLING & PRODUCING LT 2034 0 365
2003 HARLEY DRILLING & PRODUCING LT 1735 0 365
2004 HARLEY DRILLING & PRODUCING LT 1531 0 365
2005 HARLEY DRILLING & PRODUCING LT 1278 0 365
2006 HARLEY DRILLING & PRODUCING LT 1290 0 365
2007 HARLEY DRILLING & PRODUCING LT 1157 0 365
2008 HARLEY DRILLING & PRODUCING LT 452 0 365
2009 HARLEY DRILLING & PRODUCING LT 854 0 365
2010 HARLEY DRILLING & PRODUCING LT 791 0 365
2011 HARLEY DRILLING & PRODUCING LT 129 0 365
2012 HARLEY DRILLING & PRODUCING LT 616 0 366
2013 HARLEY DRILLING & PRODUCING LT 972 0 365
2014 HARLEY DRILLING & PRODUCING LT 340 1 365
2015 HARLEY DRILLING & PRODUCING LT 754 0 365
2016 HARLEY DRILLING & PRODUCING LT 691 1 365
2017 HARLEY DRILLING & PRODUCING LT 599 0 365
2018 HARLEY DRILLING & PRODUCING LT 421 0 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1983 HORTIN & HUFFMAN PET GEOL Brine 0 365
1984 HORTIN & HUFFMAN PET GEOL Brine 0 0
1985 HORTIN & HUFFMAN PET GEOL Brine 0 365
1986 HORTIN & HUFFMAN PET GEOL Brine 0 365
1988 ENOLD WALTER (COEN) Brine 0 305
1989 RUFFNER PETROLEUM CORP Brine 0 338
1990 RUFFNER PETROLEUM CORP Brine 0 365
1991 RUFFNER PETROLEUM CORP Brine 0 365
1992 HORTIN & HUFFMAN PET GEOL Brine 0 120
1993 HORTIN & HUFFMAN PET GEOL Brine 0 365
1994 HORTIN & HUFFMAN PET GEOL Brine 0 310
1995 HORTIN & HUFFMAN PET GEOL Brine 0 305
1996 HORTIN & HUFFMAN PET GEOL Brine 0 0
1997 HORTIN & HUFFMAN PET GEOL Brine 0 360
1998 HORTIN & HUFFMAN PET GEOL Brine 0 360
1999 HORTIN & HUFFMAN PET GEOL Brine 0 365
2000 HARLEY DRILLING & PRODUCING LT Brine 0 365
2001 HARLEY DRILLING & PRODUCING LT Brine 0 365
2002 HARLEY DRILLING & PRODUCING LT Brine 68 365
2003 HARLEY DRILLING & PRODUCING LT Brine 0 365
2004 HARLEY DRILLING & PRODUCING LT Brine 0 365
2005 HARLEY DRILLING & PRODUCING LT Brine 0 365
2006 HARLEY DRILLING & PRODUCING LT Brine 0 365
2007 HARLEY DRILLING & PRODUCING LT Brine 0 365
2008 HARLEY DRILLING & PRODUCING LT Brine 0 365
2009 HARLEY DRILLING & PRODUCING LT Brine 0 365
2010 HARLEY DRILLING & PRODUCING LT Brine 0 365
2011 HARLEY DRILLING & PRODUCING LT Brine 0 365
2012 HARLEY DRILLING & PRODUCING LT Brine 0 366
2013 HARLEY DRILLING & PRODUCING LT Brine 0 365
2014 HARLEY DRILLING & PRODUCING LT Brine 0 365
2015 HARLEY DRILLING & PRODUCING LT Brine 0 365
2016 HARLEY DRILLING & PRODUCING LT Brine 0 365
2017 HARLEY DRILLING & PRODUCING LT Brine 0 365
2018 HARLEY DRILLING & PRODUCING LT Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0043361399 2016-04-19 Production Wells No Violations This is a producing pump jack well. There wer no problems noted at the ime of the inspection.
0302541706 2017-03-29 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
0995968321 2018-09-26 Production Wells No Violations On the day of my inspection I found, an 8 5/8 inch diameter casing, 4 1/2 inch diameter casing, and 2 3/8 inch diameter tubing and rods, operated by a pumping unit with an electric motor. The production equipment is made up of one 100 bbl. steel tank, a 50-bbl. steel tank, a vertical separator and a rotary meter. The tanks are properly identified, and production reporting is up to date. The production equipment is shared with other wells
1079033432 2015-04-08 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
1409506837 2011-09-28 Production Wells No Violations Producing, no problems noted.
1869807025 2013-02-06 Production Wells No Violations This is now a producing pump jack well. There were no problems noted at the time of the inspection.

For data sources see[9]

References