34-173-20582

Well Details

Well ID: 34-173-20582
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality: Liberty Township
Operator Name: FO ENERGY LLC
Well Pad ID:
Farm/Lease Name: HANNA
License Status: Final Restoration
License Date: 2014-09-23
Spud Date: 2014-11-14
Spud Drilling Contractor:
Final Drill Date: 2014-11-17
Well Total Depth: 1205 ft
Configuration: Vertical
Latitude: 41.293424732
Longitude: -83.69525462

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2014-09-23 Proposed Formations:TRENTON-PRE CAMBRIAN, Issued Date:9/23/2014, Expired Date:9/22/2016 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:FWC
Reached Total Depth 2014-11-17 Huwer Drilling
Plugged/Abandoned 2015-03-03 Huwer Drilling
Completion Report Received 2015-03-23 Huwer Drilling
Construction Permit Expires 2016-09-22 Huwer Drilling
Record Last Modified 2018-07-24 Huwer Drilling

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1415718359 2014-11-10 Drill / Deepen / Reopen No Violations At the time of the inspection I was on location for the setting and cementing of the Surface Casing. Huwer Well Drilling was the drilling contractor and the cement was brought by M & R Redi-Mix. There was 450 of 7 casing set in 454 of an 8.75 hole and cemented in with 90 sacks of Class A. Cement returns were witnessed at the surface and the annulus was topped of shortly after displacement.
1425500339 2015-03-03 Plug / Plug Back No Violations Hagan Well Service of Wooster Ohio plugged existing well with 9 bag grout. Contractor pulled tubing and rods from well and baled well dry. Filled hole and casing to surface.
1486989881 2017-02-10 Final Restoration No Violations Final retoration is not approved. Well casing needs to be cut off below grade and cap welded on top of casing before final restoration can be approved.
1493306842 2017-06-05 Final Restoration No Violations Well casing has been cut off and plate installed at well. Area appears to be restored. Final restoration has been approved.

For data sources see[3]