34-055-21968

Well Details

Well ID: 34-055-21968
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chardon Township
Operator Name: OSAIR INC
Well Pad ID:
Farm/Lease Name: MURRAY
License Status: Producing
License Date: 2008-10-17
Spud Date: 2009-02-24
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2009-03-02
Well Total Depth: 3679 ft
Configuration: Vertical
Latitude: <Latitude>
Longitude: -81.20963015

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-07-16 Proposed Formations:CLINTON, Issued Date:7/16/2007, Expired Date:7/15/2008 6:00:00 AM, Drilling unit acres:24.6, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2008-10-17 Proposed Formations:CLINTON & QUEENSTON, Issued Date:10/17/2008, Expired Date:10/17/2009 6:00:00 AM, Drilling unit acres:24.6, Proposed Well Type:, Proposed Well Class:POOL
Reached Total Depth 2009-03-02
Change of Owner 2009-03-30 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 7447, GREAT PLAINS EXPLORATION LLC
Completion Report Received 2009-03-30
Construction Permit Expires 2009-10-17
Change of Owner 2012-02-08 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 957, OSAIR INC
Change of Owner 2013-12-23 Operator changed from 957, OSAIR INC to 9215, OSAIR INC. TRANSFERRED FROM #957 OSAIR CANCELED FILE TO NEW OSAIR #9215.
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-06-10 3505 3527 31

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 420 Bbl 100000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 GREAT PLAINS EXPLORATION LLC 17648 0 283
2010 GREAT PLAINS EXPLORATION LLC 7518 0 365
2011 OSAIR INC 3614 0 365
2012 OSAIR INC 2498 0 366
2013 OSAIR INC 2720 0 365
2014 OSAIR INC 3899 0 365
2015 OSAIR INC 3615 0 365
2016 OSAIR INC 4423 0 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 GREAT PLAINS EXPLORATION LLC Brine 1360 283
2010 GREAT PLAINS EXPLORATION LLC Brine 800 365
2011 OSAIR INC Brine 160 365
2012 OSAIR INC Brine 0 366
2013 OSAIR INC Brine 0 365
2014 OSAIR INC Brine 0 365
2015 OSAIR INC Brine 0 365
2016 OSAIR INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0097779403 2018-03-23 Production Wells No Violations At the time of this inspection, the well was equipped with a plunger lift assembly and the annulus and flow line valves were open. The tank battery consisted of two steel production tanks and a mechanical separator. Valves on the separator were open and the chart showed production. The tank battery was diked and had legible signage. The lease access was stable. No violations observed.
0262776461 2009-02-26 Drill / Deepen / Reopen No Violations Surface has been set, on site to pick up surface ticket. Site is in good repair. Operator was installing air body and BOP. CND was driven in. Bob Randles called from the company, operator drove in the CND pipe. Rig had a hard time running surface pipe, when tripping surface pipe out CND feel two feet into hole. Cementing of CND was waived due to bedrock being at 20. Operator had to trip back in and clean hole. Drill String was pulling tight at 140. During drilling operator did not note any Berea. From reviewing water well records and adjacent wells Berea bottom should have been between 140 and 150. Bob stated that they didnt lose any circulation, but didnt get cement to return to surface. They did get dirty water back. Operator will need to grout surface during long string.
0387251395 2009-10-21 Preliminary Restoration No Violations Area around well needs repair seeding. Seeding operator completed on site, has washed down slope. Tank battery dike has a drain installed. Drain pipe has a cap on it that is not sufficient to prevent escape of fluids if there is a leak at the battery. Restoration can not be approved at this time. Sent e-mail to Tim Reilly at John D Oil requesting repairs.
0915896064 2013-07-23 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is closed. The well and tank battery are in good repair. The tank battery consists of a short 100 BBL production tank, a short 100 BBL brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition.
1893000521 2016-03-22 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is closed. The tank battery consists of a short 100 BBL production tank, a short 100 BBL brine tank, and a mechanical separator. The load line valves have plugs installed in them but are not locked. The sales line valve on the separator is closed. There is a domestic supply plumbed off of the sales portion of the separator. The identification sign needs updated to Osair as the owner and not John D. The lease road is in stable condition. I have contacted the company about updating the identification sign.
1958696845 2009-12-02 Preliminary Restoration No Violations Site has been mulched around the well head. Vegetation is becoming established. Tank battery dike is stable. Grading has been completed. There as drainage coming from behind the tank battery off of the slope, the drainage flowed to the north end of the battery around the battery to the front of it, across the front and into a drainage culvert. Drainage has a light sediment load. Sediment didnt appear to be coming off of the dike. Lease road is stable and in good repair. Lease road gate was not installed, drive is primary drive for the landowner.

For data sources see[9]

References