34-103-22726

Well Details

Well ID: 34-103-22726
Loading map...
Country: United States
State: Ohio
County: Medina
Municipality: Sharon Township
Operator Name: HEHNS QUALITY GARDENS INC
Well Pad ID:
Farm/Lease Name: MILICH-DEVAUGHN
License Status: Producing
License Date: 1982-01-08
Spud Date: 1981-10-07
Spud Drilling Contractor:
Final Drill Date: 1981-10-15
Well Total Depth: 3791 ft
Configuration: Vertical
Latitude: 41.070861780
Longitude: -81.72154226

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1981-10-07
Completed 1981-10-15
Reached Total Depth 1981-10-15
CO 1982-01-08 646 COASTAL PETROLEUM CORP GeoDate 1/8/82
CO 1992-11-06 2348 TRIAD RESOURCES INC GeoDate 1/8/82
CO 1996-04-04 1217 HARRISON ENERGY GeoDate 1/8/82
Change of Owner 2000-12-18 Operator changed from 1217, HARRISON ENERGY to 6886, HEHNS QUALITY GARDENS INC.
Last Compliance Report 2014-06-02
Record Last Modified 2015-09-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3636 3640 0
2006-09-11 3628 3634 18
2006-09-11 3654 3661 0
2006-09-11 3642 3646 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1992 TRIAD RESOURCES INC 812 558 365
1993 TRIAD RESOURCES INC 1513 215 365
1994 TRIAD RESOURCES INC 1132 99 365
1995 TRIAD RESOURCES INC 597 108 365
1996 HARRISON ENERGY 333 0 200
1997 HARRISON ENERGY 448 24 200
1998 HARRISON ENERGY 769 0 365
1999 HARRISON ENERGY 544 0 365
2000 HARRISON ENERGY 153 0 365
2002 HEHNS QUALITY GARDENS INC 419 60 365
2005 HEHNS QUALITY GARDENS INC 474 50 242
2006 HEHNS QUALITY GARDENS INC 252 28 365
2007 HEHNS QUALITY GARDENS INC 229 48 365
2008 HEHNS QUALITY GARDENS INC 108 28 365
2009 HEHNS QUALITY GARDENS INC 79 32 365
2010 HEHNS QUALITY GARDENS INC 321 25 365
2011 HEHNS QUALITY GARDENS INC 150 20 265
2012 HEHNS QUALITY GARDENS INC 200 28 180
2013 HEHNS QUALITY GARDENS INC 479 21 365
2014 HEHNS QUALITY GARDENS INC 255 8 365
2015 HEHNS QUALITY GARDENS INC 210 16 365
2016 HEHNS QUALITY GARDENS INC 130 0 365
2017 HEHNS QUALITY GARDENS INC 120 0 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1992 TRIAD RESOURCES INC Brine 120 365
1993 TRIAD RESOURCES INC Brine 40 365
1994 TRIAD RESOURCES INC Brine 50 365
1995 TRIAD RESOURCES INC Brine 0 365
1996 HARRISON ENERGY Brine 0 200
1997 HARRISON ENERGY Brine 0 200
1998 HARRISON ENERGY Brine 0 365
1999 HARRISON ENERGY Brine 0 365
2000 HARRISON ENERGY Brine 0 365
2002 HEHNS QUALITY GARDENS INC Brine 33 365
2005 HEHNS QUALITY GARDENS INC Brine 15 242
2006 HEHNS QUALITY GARDENS INC Brine 3 365
2007 HEHNS QUALITY GARDENS INC Brine 56 365
2008 HEHNS QUALITY GARDENS INC Brine 28 365
2009 HEHNS QUALITY GARDENS INC Brine 12 365
2010 HEHNS QUALITY GARDENS INC Brine 0 365
2011 HEHNS QUALITY GARDENS INC Brine 0 265
2012 HEHNS QUALITY GARDENS INC Brine 0 180
2013 HEHNS QUALITY GARDENS INC Brine 0 365
2014 HEHNS QUALITY GARDENS INC Brine 0 365
2015 HEHNS QUALITY GARDENS INC Brine 0 365
2016 HEHNS QUALITY GARDENS INC Brine 0 365
2017 HEHNS QUALITY GARDENS INC Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
000PL12093 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0475104426 2014-05-08 Production Wells No Violations Inspected production well on 05/08/2014. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, and a vertical separator located within an earthen dike. A gas leak was noted at the piping near the separator. It appeared that an attempt had been made to repair it previously, but looks to need additional work. The tank battery is used by multiple wells; identification is posted for all wells utilizing it, but the identification stickers are too faded to read. The well is equipped with a pump jack with an electric motor. No identification is posted at the wellhead. An additional 100 bbl steel tank is located near the wellhead, but there is no identification posted on it. George Hehn with Hehns Quality Gardens was notified of the leak at the separator and need for new identification at both the tank battery and the wellhead and will address it as soon as possible. No other problems were noted at the time of the inspection.
0489167421 2004-10-27 Annular Disposal No Violations No annular disposal hookup on well. Equipped with pump jack, rods and tubing. 1-100 barrel tank with separator in battery. Sun, 65 degrees.
1517250648 2009-12-11 Annular Disposal No Violations No annular disposal hookup at well. Equipped with pump jack, 1-100 barrel tank and separator in battery. Sun, 20 degrees.

For data sources see[8]

References