X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-013-20689

Well Details

Well ID: 34-013-20689
Loading map...
Country: United States
State: Ohio
County: Belmont
Municipality: Kirkwood Township
Operator Name: GULFPORT ENERGY CORPORATION
Well Pad ID: US-OH-000530
Farm/Lease Name: SHUGERT
License Status: Producing
License Date: 2013-07-03
Spud Date: 2013-06-11
Spud Drilling Contractor: SIDEWINDER DRILLING INC
Final Drill Date: 2013-08-16
Well Total Depth: 14710 ft
Configuration: Horizontal
Latitude: 40.043069528
Longitude: -81.12317118

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-03-12 Proposed Formations:TRENTON, Issued Date:3/12/2013, Expired Date:3/12/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2013-07-03 Proposed Formations:POINT PLEASANT, Issued Date:7/3/2013, Expired Date:7/3/2015 12:00:00 PM, Drilling unit acres:640, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2013-08-16
Correction to Well 2013-11-29 CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGE AND COORDINATES) FROM AS DRILLED SURVEY PLAT.
Completion Report Received 2014-09-11
Construction Permit Expires 2015-07-03
Record Last Modified 2017-10-24

For data sources see[2]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 11/05/2013 11/11/2013 8657 6,498,990.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 IC-250 Stingray Corossion Inhibitor Water 7732-18-5 80 0 0
Proprietary polycarboxylic acid mixture Not Available 20 0 0
Entegrate NE 1100 U.S. Water Demulsifier Water 7732-18-5 60 0.02579 0
Ethylene/Propylene Oxide Polymer Not Available 40 0.0172 0
Clean Gel Stingray Guar Gel heavy aliphatic Not Available 35 0.02067 0
Solvent naphtha, (petroleum) 64742-96-7 65 0.03838 0
Fresh water Stingray Carrier Water 7732-18-5 100 86.0083 0
30/50 White Minerva/Cadiz Proppant Sand 14808-60-7 100 0 0
100 mesh Minerva/Cadiz Proppant Sand 14808-60-7 100 0.2357 0
Citric Acid 50% Pace International Acid Water 7732-18-5 50 0.1283 0
citric acid 77-92-9 50 0.1283 0
Entegrate SC8060 WB U.S. Water Scale Inhibitor Water 7732-18-5 59 0.00588 0
Phosphoric Acid 7664-38-2 1 0.0001 0
Aminotrimethylene Phosphonic Acid 6419-19-8 10 0.001 0
2-propenoic acid, sodium salt, polymer 37350-42-8 10 0.001 0
Methyl Alcohol 67-56-1 20 0.00199 0
Entegrate FR 7170 U.S. Water Friction Reducer Alcohols (C10-16), ethoxylated 68002-97-1 3.1 0.00307 0
Petroleum distillate hydrotreated light 64742-47-8 28 0.02774 0
Ammonium chloride 12125-02-9 15 0.01486 0
Alcohols (C12-16), ethoxylated 68551-12-2 3.1 0.00307 0
Water 7732-18-5 48 0.04755 0
C12-C14 Alcohol ethoxylated 68439-50-9 3.1 0.00307 0
BioClear 5000 Weatherford Biocide Water 7732-18-5 95 0.02269 0
2,2-dibromo-3-nitril oprop ionam ide 10222-01-2 5 0.00119 0
PROCLEAN 200 U.S. Water Corossion Inhibitor Citric Acid, Food Grade 77-92-9 52 0.00074 0
Water 7732-18-5 48 0.00069 0
Entecide QG40 U.S. Water Breaker n-ALKYL DIMETHYL BENZYL AMMONIUM CHLORIDE 68424-85-1 5.5 0.00024 0
DIDECYL DIMETHYL AMMONIUM CHLORIDE 7173-51-5 8.3 0.00036 0
GLUTARALDEHYDE 111-30-8 27 0.00117 0
ETHANOL 64-17-5 2.8 0.00012 0
Water 7732-18-5 56.4 0.00245 0
X-linker Stingray Guar Gel Water 7732-18-5 70 0 0
Ethylene Glycol Not Available 30 0 0
Per Break Stingray Breaker Ammonium Persulfate 7727-54-0 99 0 0
40/70 White Minerva/Cadiz Proppant Sand 14808-60-7 100 13.2584 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2013-11-06 H2O 15 346941 Gal 496054 STINGRAY PRESSURE PUMPING LLC STAGE 1/21

60 SHOTS STAGES 2-20 SEE IMAGES

2013-11-11 H2O 15 278212 Gal 493972 STINGRAY PRESSURE PUMPING LLC STAGE 21/21

60 SHOTS

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2013 GULFPORT ENERGY CORPORATION 157952 684 17
2014 GULFPORT ENERGY CORPORATION 1800064 2427 335
2015 GULFPORT ENERGY CORPORATION 978160 65 336
2016 GULFPORT ENERGY CORPORATION 707089 0 332
2017 GULFPORT ENERGY CORPORATION 479333 2 365
2018 GULFPORT ENERGY CORPORATION 305287 0 363
2019 GULFPORT ENERGY CORPORATION 60647 1 90

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2013 GULFPORT ENERGY CORPORATION Brine 4482 17
2014 GULFPORT ENERGY CORPORATION Brine 5030 335
2015 GULFPORT ENERGY CORPORATION Brine 157 336
2016 GULFPORT ENERGY CORPORATION Brine 1856 332
2017 GULFPORT ENERGY CORPORATION Brine 2114 365
2018 GULFPORT ENERGY CORPORATION Brine 1168 363
2019 GULFPORT ENERGY CORPORATION Brine 261 90

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0213826222 2018-05-15 Production Wells No Violations On the day of my inspection I witnessed that the well was equipped with 5.5 inch diameter production casing with a plunger lift system, all valves were open at the time of my inspection. Annular pressure monitoring was in place for the 9.625 inch diameter casing gauge read 0 pounds per square inch, the 13.375 inch diameter casing gauge read 600 pounds per square inch. Production equipment included a Separator, Gas Processing unit, line heater. There are 6- 400 barrel purge tanks shared with 3401320706, 3401320657, 3401320688. Identification tags were present, and production was up to date. No violations were found at the time of my inspection.
0258283035 2013-08-19 Drill / Deepen / Reopen No Violations On the day of my inspection Sidewinder 121 had reached total depth @ 14,710 . They will run 5.5 casing soon. No violations noted.
0715219986 2017-08-10 Production Wells No Violations This well is equipped with 5.5-inch diameter production casing. The well appears to be free flowing without any artificial lift technology present at this time. The well is piped to a gas processing unit and then to six 400 barrel production fluid holding tanks. Production records in RBDMS are current to 2017.
0731788820 2013-08-01 Drill / Deepen / Reopen No Violations On the day of my inspection Sidewinder #121 was drilling to kick off point. No violations noted.
0735297878 2019-01-10 Production Wells No Violations On site inspection found the well equipped with a lower A and upper B section with 2 diameter riser pipes attached to both sections, the riser pipes are equipped with valves and gauges for annular pressure monitoring with zero pounds on the A section and 400 pounds pressure present on the B section. The well is producing through the production tree with 3 primary master gate valves and one hydraulic valve present on the production tree. The well is equipped with artificial lift technology. There is an emergency shut down control button at the well head along with at the production fluid storage area and at the well pad entry along with the gas processing units. The production facility consists of (6) steel construction tanks situated inside a polymer lined steel containment dike area. The well pad perimeter does not have a complete earthen berm surrounding it. The well pad surface and lease road is stone construction and in good repair. There is well identification on each of the (4) wells present on the pad along with at the well pad entry point. The tank battery has hazard warning labels.
0953541902 2013-07-29 Drill / Deepen / Reopen No Violations On the day of my inspection Sidewinder #121 was attempting to drill ahead to kick off point. No violations noted.
0966712128 2013-08-21 Drill / Deepen / Reopen No Violations On the day of my inspection Sidewinder 121 was having trouble preparing to run 5.5 casing. No violation noted.
1004555602 2013-07-18 Drill / Deepen / Reopen No Violations On the day of my inspection Sidewinder 121 was rigging up on location. No violations noted.
1293812379 2013-08-13 Drill / Deepen / Reopen No Violations On the day of my inspection Sidewinder 121 was drilling ahead and nearing total depth. No violations noted.
1374623978 2013-07-23 Casing String Witnessed No Violations On site to witness cementing of 16 surface casing they drilled to 447 of 20 hole and ran 422 of 16 -65# per ft. and casing was equipped with 1-guide shoe and 2-centralizers and Stingray cemented casing with 490 sacks of Class A cement and they had 21 bbl returns and cement stayed up good.
1375053248 2013-07-28 Casing String Witnessed No Violations On the day of my inspection Sidewinder 121 had reached TD and 10.34 casing ran. Stingray cemented. See cement ticket for details. No violations noted.
1495017609 2013-07-31 Drill / Deepen / Reopen No Violations On the day of my inspection Sidewinder #121 was making a bit trip and would continue drilling ahead to kick off point following trip. No violations noted.
1622361675 2013-07-22 Drill / Deepen / Reopen No Violations On the day of my inspection Sidewinder 121 had reached total depth and was tripping out of the hole. They will run and cement 16 casing tonight. No violations noted.
1683863358 2013-08-15 Drill / Deepen / Reopen No Violations On the day of my inspection Sidewinder 121 was drilling @ 14,400. No violations noted.
1955108826 2013-10-24 Drill / Deepen / Reopen No Violations On the day of my inspection I was accompanied by Dept. of Commerce electrical inspector and Brad Sellers. We conducted an electrical inspection and are currently waiting on response from Commerce.

For data sources see[9]

References