37-125-27515

Well Details

Well ID: 37-125-27515
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 145213
Farm/Lease Name: R SMITH 592296
License Status: Active
Spud Date: 2015-04-21
Permit Date: 2014-11-07
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 40.164686
Longitude: -79.944344

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2015-09-08 2015-09-16 7679.61 7,567,480.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FR-18 C and J Energy Services Anionic friction reducer Ethylene glycol 107-21-1 10 0.00814552 5739.4
Distillates (petroleum), hydrotreated light 64742-47-8 45 0.0366548 25827.3
Water C and J Energy Services Carrier/Base Fluid Water 7732-18-5 100 89.6251 63,150,600.0
Hydrochloric Acid (15%) C and J Energy Services Acidizing Hydrochloric Acid 7647-01-0 15 0.0294636 20760.3
MC MX 437-5 Multi-Chem Group Calcium nitrate solution Calcium nitrate 10124-37-5 60 0.0574501 40479.8
Sand (Proppant) C and J Energy Services Proppant Silica Substrate 14808-60-7 100 9.97817 7,030,700.0
AI-2 C and J Energy Services Acid corrosion inhibitor Glycol ethers 111-76-2 40 0.00014539 102.443
Tar bases, quinoline derivs, benzyl chloride-qauternized 72480-70-7 10 0.00003635 25.611
Ethoxylated nonylphenol 68412-54-4 13 0.00004725 33.294
Isopropyl alcohol 67-63-0 40 0.00014539 102.443
Propargyl alcohol 107-19-7 40 0.00014539 102.443
SI-4 C and J Energy Services Scale inhibitor Bis(hexamethylene triaminepenta methylenephosphonic acid) Proprietary 10 0.00226861 1598.48
Sodium hydroxide 1310-73-2 1 0.00022686 159.848

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2015 EQT PROD CO 236,838.00 39 0.00 0 0.00 0
2016 EQT PROD CO 2,312,791.00 347 0.00 0 0.00 0
2017 EQT PROD CO 1,174,934.00 364 0.00 0 0.00 0
2018 EQT PROD CO 774,134.00 342 0.00 0 0.00 0
2019 EQT PROD CO 149,743.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2015 EQT PROD CO Fracturing Fluid Waste (in Tons) 56.87 Tons LANDFILL SWF 1032-WV0109
2015 EQT PROD CO Produced Fluid (in Barrels) 330.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 EQT PROD CO Drill Cuttings (in Tons) 362.00 Tons LANDFILL 100419
2015 EQT PROD CO Fracing Fluid Waste (in Barrels) 2,640.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 EQT PROD CO Drill Cuttings (in Tons) 531.98 Tons LANDFILL 100277
2015 EQT PROD CO Fracturing Fluid Waste (in Tons) 26.94 Tons LANDFILL 100277
2015 EQT PROD CO Produced Fluid (in Barrels) 2,970.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Drilling Fluid Waste (in Barrels) 505.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Fracing Fluid Waste (in Barrels) 4,605.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Fracturing Fluid Waste (in Barrels) RWC 805 820.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid (in Barrels) RWC 802 12,180.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Other Oil & Gas Wastes (in Barrels) RWC 899 260.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid (in Barrels) RWC 802 540.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 EQT PROD CO Produced Fluid (in Barrels) RWC 802 243.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2017 EQT PROD CO Produced Fluid (in Barrels) RWC 802 1,170.62 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Other Oil & Gas Wastes (in Barrels) RWC 899 65.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Other Oil & Gas Wastes (in Barrels) RWC 899 330.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid (in Barrels) RWC 802 37.25 Bbl INJECTION DISPOSAL WELL 34-031-27177
2017 EQT PROD CO Produced Fluid (in Barrels) RWC 802 130.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 EQT PROD CO Produced Fluid (in Barrels) RWC 802 553.61 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid (in Barrels) RWC 802 6.64 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018 EQT PROD CO Produced Fluid (in Barrels) RWC 802 196.53 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid (in Barrels) RWC 802 44.11 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Other Oil & Gas Wastes (in Barrels) RWC 899 10.45 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018 EQT PROD CO Other Oil & Gas Wastes (in Barrels) RWC 899 10.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Other Oil & Gas Wastes (in Barrels) RWC 899 10.45 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Other Oil & Gas Wastes (in Barrels) RWC 899 47.94 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes (in Barrels) RWC 899 91.36 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid (in Barrels) RWC 802 250.94 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid (in Barrels) RWC 802 17.85 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Produced Fluid (in Barrels) RWC 802 264.61 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid (in Barrels) RWC 802 1.49 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Other Oil & Gas Wastes (in Barrels) RWC 899 30.00 Bbl INJECTION DISPOSAL WELL 34-105-23619
2019 EQT PROD CO Other Oil & Gas Wastes (in Barrels) RWC 899 40.00 Bbl INJECTION DISPOSAL WELL 2D0859721
2019 EQT PROD CO Other Oil & Gas Wastes (in Barrels) RWC 899 188.63 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid (in Barrels) RWC 802 3.27 Bbl INJECTION DISPOSAL WELL 2D0859721
2019 EQT PROD CO Produced Fluid (in Barrels) RWC 802 4.91 Bbl INJECTION DISPOSAL WELL 34-105-23619
2019 EQT PROD CO Produced Fluid (in Barrels) RWC 802 1.31 Bbl INJECTION DISPOSAL WELL 34-167-29543
2019 EQT PROD CO Produced Fluid (in Barrels) RWC 802 95.65 Bbl INJECTION DISPOSAL WELL 34-009-23823

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2350211 Primary Facility 2015-03-10 Routine/Complete Inspection No Violations Noted
2363483 Primary Facility 2015-04-22 Drilling/Alteration No Violations Noted Himes Diversified auger rig
2378203 Primary Facility 2015-06-10 Drilling/Alteration No Violations Noted Alpha Hunter Rig #8
2393699 Primary Facility 2015-07-28 Drilling/Alteration No Violations Noted Orion Drilling Rig #18
2400427 Primary Facility 2015-08-19 Drilling/Alteration No Violations Noted Orion Drilling Rig #18
2402146 Primary Facility 2015-08-14 Compliance Evaluation No Violations Noted On 8/14/15, I inspected the Robert Smith site as a compliance evaluation inspection in response to the remediation report for a spill occurring on 1/31/15 and made the following observations:
2544069 Primary Facility 2016-09-14 Incident- Response to Accident or Event No Violations Noted On 9/14/16 I performed an incident response inspection at the Robert Smith Site in response to an operator reported spill (CTS ID: 322335) and made the following observations:

•On 9/6/16 EQT Corey Giles reported a spill of 100 gallons of produced fluids to the well pad. The spill was forwarded to the WQS on 9/14/16. This constitutes a violation of 25 Pa. Code § 78.57(a) and 25 Pa. Code § 78.54 for failing to control brine and other fluids resulting in discharge to the ground and failure to prevent pollution to the Waters of the Commonwealth. •The spill was cleaned up at the time of inspection with the only observed indicator of the spill location being an area of new gravel on the pad near the production units. No violation. •Well drilling was ongoing at the time of inspection. •During general pad inspection it was noted that multiple production tanks had orange streaking running down their sides from the top of the tanks. The gravel of the pad surface near the containment displayed matching orange stai

2614157 Primary Facility 2017-05-05 Incident- Response to Accident or Event In Compliance with Policy On 5/5/17 an INCDT inspection of the R. Smith well site was conducted in response to CTS ID: 326715. The following was observed:

>> Site was undergoing fracking at time of inspection.

>>The spill in question involved roughly 10 gallons of produced water being sprayed from from an overfilled accessory tank on the pad. Affected pad materials were collected and placed in a waste box on pad for disposal. No violation, site appears to be in compliance with policy.

>>Streaking was again noted on the outside of multiple production tanks similar to streaking noted in previous inspections.

2660140 Primary Facility 2017-11-09 Routine/Complete Inspection No Violations Noted On 11/10/17 a routine complete inspection of the R. Smith well site was conducted in response to notification additional drilling on site. The following was observed:

>>A box tank was found near the impoundment with no containment. Remediation recommended, no violation.

>>A new top soil stock pile was noted on site. It was stabilized with straw at the time of inspection.

>>The soil stock pile was noted to not have any functional controls below it other than an adequate vegetated strip. Decomposed CFS should be removed, repaired, or replaced. No violation.

>>Drilling was ongoing at the site at the time of inspection.

2660152 Primary Facility 2017-11-09 Routine/Complete Inspection No Violations Noted On 11/10/17 a routine complete inspection of the R. Smith well site was conducted in response to notification additional drilling on site. The following was observed:

>>A box tank was found near the impoundment with no containment. Remediation recommended, no violation.

>>A new top soil stock pile was noted on site. It was stabilized with straw at the time of inspection.

>>The soil stock pile was noted to not have any functional controls below it other than an adequate vegetated strip. Decomposed CFS should be removed, repaired, or replaced. No violation.

>>Drilling was ongoing at the site at the time of inspection.

2691661 Primary Facility 2018-02-02 Routine/Complete Inspection No Violations Noted Well has been fracked and is producing.
2705569 Primary Facility 2018-03-13 Routine/Partial Inspection No Violations Noted On 3/14/18 a routine complete inspection of the R. Smith Well Site was conducted in response to a notification of proposed construction activity on the pad. The following was observed:

>>The site was in a high activity phase at the time of inspection drilling appeared to be completed and the site was in apparent transition to post drilling activities. No drilling rig was present on site at the time of inspection.

>>Construction of a proposed AST had not begun at the time of inspection.

>>Many water trucks were present on site in association with the attached impoundment.

2737825 Primary Facility 2018-05-16 Incident- Response to Accident or Event No Violations Noted On 5/16/18 an incident inspection of the R. Smith well site was conducted in response to a spill reported by the operator on 5/14/18. The following was observed:

>>The operator reported that roughly 35 gallons of mixed rain water and produced water was spilled to the pad when a section of containment was moved without being drained first. Fluids were spread over a large area of the pad along the area in front of the production units per discussion with Mike Cromley at the time of inspection. This does constitute a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents prevents pollution to the ground or Waters of the Commonwealth however, the violation is regarded as immediately corrected.

>>Site inspection found no residual evidence of the spill. The operator reported that all visibly impacted gravel from the spill area had been removed (roughly two clamshell dumpsters).

2747164 Primary Facility 2018-06-29 Routine/Partial Inspection No Violations Noted On 6/29/18 a routine partial inspection of the R. Smith Well Site was conducted in response to concerns about runoff raised by a nearby resident. The following was observed:

>>An unstabilized soil pile near the corner of the pad with a newly improved drain. Controls below the pile were absent though the vegetation was sufficient. No violation, remediation recommended.

>>Another only partially stabilized soil pile with no controls below the pile was located along the accessory pad access road. No controls beyond vegetation were present below the soil pile. No violation, monitoring recommended.

>>An AST was present on the accessory pad.

>>The pad was active at the time of inspection with drilling preparations ongoing. A sound wall was present around the pad perimeter.

2761859 Primary Facility 2018-08-02 Routine/Complete Inspection No Violations Noted On 8/2/18 a complaint response inspection was conducted of the R Smith well site in response to reported concerns of inappropriate drainage from the pad. WQSS John Carson accompanied. The following was observed:

>>A top soil pile on the access road to the accessory pad remained lacking vegetation and with spotty temporary stabilization. The vegetative strip below remains in good condition. Remediation recommended, no violation.

>>Emptying partially filled containment is encouraged to aid in identifying any possible leaks. No violation.

>>No evidence of excessive or unpermitted runoff from the pad was found.

>>Box in containment appears to be collecting emergency blowdown. If so it should be properly marked. No violation.

For data sources see[7]

References