If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-125-27588 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.072892,"lon":-80.197964,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: Amwell Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 146837 | |
Farm/Lease Name: F I MONINGER 592366 | |
License Status: Active | |
Spud Date: 2015-08-19 | |
Permit Date: 2015-02-10 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 40.072892 | |
Longitude: -80.197964 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2016-04-01 | 2016-04-14 | 7692 | 4,100,800.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | LD-2550 | Multi-Chem Group | Additive | Sodium chloride | 7647-14-5 | 10 | 0.000562774 | 216.068 |
Inner salt of alkyl amines | Proprietary | 60 | 0.00337664 | 1296.41 | ||||
Water | FTS International | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 89.1331 | 34,221,100.0 | |
LD-2250 | Multi-Chem Group | Friction Reducer | Sodium chloride | 7647-14-5 | 5 | 0.000910103 | 349.418 | |
Polyacrylate | Proprietary | 30 | 0.00546061 | 2096.51 | ||||
Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.00546061 | 2096.51 | ||||
Athoxylated alcohol | Proprietary | 5 | 0.000910103 | 349.418 | ||||
Fatty nitrogen derived amides | Proprietary | 5 | 0.000910103 | 349.418 | ||||
Sand (Proppant) | FTS International | Proppant | Silica Substrate | 14808-60-7 | 100 | 10.4317 | 4,005,080.0 | |
HVG-1 4.0 | FTS International | Water Gelling Agent | Surfactant | 68439-51-0 | 2 | 0.00000704 | 2.704 | |
Clay | 14808-60-7 | 2 | 0.00000704 | 2.704 | ||||
Petroleum Distallate | 64742-47-8 | 55 | 0.000193664 | 74.354 | ||||
Guar Gum | 9000-30-0 | 50 | 0.000176058 | 67.595 | ||||
Cl-150 | FTS International | Acid Corrosion Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.000122654 | 47.091 | |
Aromatic aldehyde | Proprietary | 10 | 0.00004088 | 15.697 | ||||
Quaternary ammonium compound | Proprietary | 10 | 0.00004088 | 15.697 | ||||
Organic amine resin salt | Proprietary | 30 | 0.000122654 | 47.091 | ||||
Dimethylformamide | 68-12-2 | 10 | 0.00004088 | 15.697 | ||||
Isopropanol | 67-63-0 | 30 | 0.000122654 | 47.091 | ||||
MC MX 5-3886 | Multi-Chem Group | Specialty Brine | Calcium nitrate.4H2O | 13477-34-4 | 100 | 0.11176 | 42908.3 | |
MC MX 8-2544 | Multi-Chem Group | Live Culture - Nitrate Reducing Bacteria | Sodium chloride | 7647-14-5 | 100 | 0.00994793 | 3819.34 | |
Sodium Nitrate | 7631-99-4 | 5 | 0.000497397 | 190.967 | ||||
Hydrochloric Acid (15%) | FTS International | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0331413 | 12724 | |
CS-500 SI | FTS International | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 10 | 0.00252107 | 967.924 | |
FRW-900 | FTS International | Friction Reducer | Oxyalkylated alcohol A | Proprietary | 5 | 0.002137 | 820.464 | |
Alkyl Alcohol | Proprietary | 10 | 0.00427399 | 1640.93 | ||||
Hydrotreated Light Distillate | 64742-47-8 | 30 | 0.012822 | 4922.78 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2015 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 1,086,713.00 | 224 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 737,325.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 540,191.00 | 361 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 106,336.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 245.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2015 | EQT PROD CO | Drill Cuttings (in Tons) | 130.00 Tons | LANDFILL | 100419 |
2015 | EQT PROD CO | Drill Cuttings (in Tons) | 557.31 Tons | LANDFILL | 100277 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 260.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Drilling Fluid Waste (in Barrels) | 895.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Drill Cuttings (in Tons) RWC 810 | 201.51 Tons | LANDFILL | 100419 |
2016 | EQT PROD CO | Fracturing Fluid Waste (in Barrels) RWC 805 | 110.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 18,834.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Other Oil & Gas Wastes (in Barrels) RWC 899 | 1,305.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 115.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 1,310.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2016 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 212.54 Bbl | LANDFILL | 100277 |
2016 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2016 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 970.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 108.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2016 | EQT PROD CO | Drilling Fluid Waste (in Barrels) RWC 803 | 130.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Waste Water Treatment Sludge (in Tons) RWC 804 | 100.51 Tons | RESIDUAL WASTE PROCESSING FACILITY | 2014-541 |
2016 | EQT PROD CO | Other Oil & Gas Wastes (in Tons) RWC 899 | 4.78 Tons | LANDFILL | 100419 |
2017 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 2,160.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 540.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 267.70 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 16.89 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | EQT PROD CO | Other Oil & Gas Wastes (in Barrels) RWC 899 | 235.38 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 108.56 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 158.31 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | EQT PROD CO | Other Oil & Gas Wastes (in Barrels) RWC 899 | 85.38 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 414.02 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 58.78 Bbl | INJECTION DISPOSAL WELL | 34-167-29543 |
2019 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 69.49 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2364125 | Primary Facility | 2015-03-12 | Routine/Complete Inspection | No Violations Noted | A routine Inspection performed in conjunction with a water supply complaint inspection (ID#2364119). Proper signage and all records including the ESCGP, well permits, PPC, ERP, containment plan, E&S plan and drawings and PCSM plan located on-site. There is a freshwater impoundment located on-site which had little water stored during this inspection. There is currently no drilling activity on-site. There is one existing well (125-23192) and three wells (125-27425, 125-27435 and 125-27436) have been spud and vertical portions drilled between 12/23/14 and 1/3/15; the laterals plan to be drilled in the spring/summer. 5 additional wells were recently permitted but have not been spud as of this inspection. The diversion channels (channels 1 &2) along the backside of the FW Impoundment (E) may need re-graded as there was some water ponding. All areas on-site appear to be temporarily stabilized with matting and all of the E&S controls are installed and appear to be functioning appropriately. There were no violations noted during this inspection. |
2394984 | Primary Facility | 2015-06-02 | Routine/Complete Inspection | No Violations Noted | |
2401420 | Primary Facility | 2015-08-21 | Drilling/Alteration | No Violations Noted | Himes Diversified auger rig |
2415571 | Primary Facility | 2015-10-14 | Drilling/Alteration | No Violations Noted | Alpha Hunter Drilling Rig #6 |
2418111 | Primary Facility | 2015-10-21 | Drilling/Alteration | No Violations Noted | Alpha Hunter Drilling Rig #6 |
2439740 | Primary Facility | 2015-01-08 | Drilling/Alteration | No Violations Noted | Orion Drilling Rig #17 |
2444496 | Primary Facility | 2016-01-26 | Drilling/Alteration | No Violations Noted | Orion Drilling Rig #17
TD was at 10,796 ft. MD (7691 ft. TVD) on 1/9/2016. The 5 ½” casing was set at 10,792 ft. The estimated top of cement is at 3501 ft. |
2593312 | Primary Facility | 2017-05-15 | Routine/Complete Inspection | No Violations Noted | On Monday, May 5, 2017, I completed a routine-complete inspection at the Cashdollar Well Site located in Amwell Township, Washington County.
The Act 9 sign was in place and clearly legible at the site entrance which is secured with a gate and a lock. The access road and well pad are in good condition and the site is stabilized with vegetative growth. The operator may consider re-evaluating the vegetation on-site to determine the necessity of keeping the filter sock and silt fence in place or whether it can be removed. The operator should also continue their periodic monitoring program and address any deficiencies, signs of accelerated erosion and/or sedimentation upon identification. The secondary containment structure around the production tanks appear to be in good condition and functioning as intended. The gas wells appear to be in good working order and are labeled as required. No violations were noted during the inspection. |
2821156 | Primary Facility | 2019-01-02 | Routine/Complete Inspection | No Violations Noted | Today I conducted a routine inspection at the Cash Dollar well pad and the following was observed.
Proper signs were displayed identifying the site. The access road was maintained and in good condition. The outer slopes were stabilized with thick vegetation no erosion observed outside of the LOD. The well heads were maintained no leaks or defects observed. The production tanks were in good condition no defects or leaks.The production tanks secondary containment was intact.
|
For data sources see[7]