If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-105-21412 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.837585,"lon":-77.737741,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Potter | |
Municipality: Ulysses Township | |
Operator Name: WATER TERRIER LLC | |
Well Pad ID: | |
Farm/Lease Name: HEADWATERS WC P3 | |
License Status: Plugged OG Well | |
Spud Date: 2008-10-01 | |
Permit Date: 2008-01-03 | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Latitude: 41.837585 | |
Longitude: -77.737741 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | WATER TERRIER LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | WATER TERRIER LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | WATER TERRIER LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | WATER TERRIER LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1903573 | Primary Facility | 2010-06-21 | Complaint Inspection | Violation(s) Noted | Complaint #272172 |
2001641 | Primary Facility | 2011-08-31 | Compliance Evaluation | No Violations Noted | A site visit was conducted on 8/31/11 at 1415 to follow up on violations cited for 78.56(2) - Failure to maintain 2' freeboard in an impoundment and 78.65(2) - Failure to restore site within 30 days of permit expiration when well not drilled during a 6/21/10 inspection (1903573). The surface of the pad has been stabilized. The pit appears to have been reclaimed / removed. Based on this inspection the violations noted above have been resolved. The well pad is sparsely vegetated and should be seeded and mulched to reduce the potential for accelerated erosion. |
2095290 | Primary Facility | 2012-08-10 | Routine/Complete Inspection | Violation(s) Noted | |
2216520 | Primary Facility | 2013-10-22 | Follow-up Inspection | No Violations Noted | |
2316816 | Primary Facility | 2014-10-21 | Follow-up Inspection | No Violations Noted | |
2587029 | Primary Facility | 2017-04-24 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Inspection of Water Terrier’s Headwaters P3 well conducted April 24, 2017 at 10 am. ALCO was rigged up on the pad for plugging ops. They tagged TD @ 3270’, I went over depths and pump volumes with rig company and cementer. Cementer pumped gel ahead of (4) balanced cement plugs in the open hole. We saw good rate and returns throughout the job, all joints pulled dry, slurry looked good. No Issues. |
2590403 | Primary Facility | 2017-04-28 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Routine Inspection of Water Terrier’s now plugged Headwaters P3 well conducted April 28, 2017 at 11:40 am. ALCO is rigged down and there is a 2” candycane monument on the well. No measurable flow was observed. I left location at about noon. No issues. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1903573 | 592537 | 06/21/2010 | 2010-06-21 | 78.56(2) - Failure to maintain 2 ' of freeboard in an impoundment. | Administrative | 78.56(a)(2). Failure to maintain 2 feet of freeboard in pit. |
1903573 | 593715 | 06/21/2010 | 2010-06-21 | 78.65(2)* - Failure to restore site within 30 days of permit expiration when well not drilled | Environmental Health & Safety | 78.65(2) for failure to restore the well site within 30 days of permit expiration. Permit issued 1-3-08. It has been determined that well not drilled with due diligence. As per Oil and Gas Act section 601.201(i), the permit is considered expired. TLT |
2095290 | 647763 | 08/10/2012 | 2012-08-10 | 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling | Administrative | No ID |
2095290 | 647764 | 08/10/2012 | 2012-08-10 | 78.73(a) - GENERAL PROVISION FOR WELL CONSTRUCTION AND OPERATION - Operator failed to construct and operate the well in accordance with 25 Pa. Code Chapter 78 and ensure that the integrity of the well is maintained and health, safety, environment and | Environmental Health & Safety | Insufficient barriers |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
592537 | 261886 | NOV - Notice of Violation | Comply/Closed | 2011-08-31 | |||
593715 | 261886 | NOV - Notice of Violation | Comply/Closed | 2011-08-31 | |||
647763 | 334100 | COA - Consent Order and Agreement | Comply/Closed | 2016-01-28 | |||
647764 | 334100 | COA - Consent Order and Agreement | Comply/Closed | 2016-01-28 |
For data sources see[5]