37-015-21960

Well Details

Well ID: 37-015-21960
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Stevens Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 147919
Farm/Lease Name: CAMPBELL ERCOLE DEMENTO 3H
License Status: Active
Spud Date: 2012-06-06
Permit Date: 2011-10-05
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.787550
Longitude: -76.178908

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-10-04 2012-10-04 6059.00 4,153,968.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FRA-405 Clearwater International Friction Reducer Ammonium chloride 12125-02-9 5.00 0.00422000
Sodium chloride 7647-14-5 7.50 0.00633000
Ethoxylated C12-16 alcohols 68551-12-2 5.00 0.00422000
Distillates, petroleum, hydrotreated light 64742-47-8 27.50 0.02
SI-115 Clearwater International Scale Inhibitor Phosphonic acid, [[(phosphonomethyl)imino]bis[2,1-ethanediylnitrilobis(methylene)]]tetrakis-,
sodium salt
22042-96-2 20.00 0.00237000
Sodium chloride 7647-14-5 5.00 0.00059000
15 HCl Acid Hydrochloric acid 7647-01-0 15.00 0.12
AI-250 Clearwater International Acid Inhibitor 2-Butoxyethanol 111-76-2 40.00 0.00084000
Isopropanol 67-63-0 40.00 0.00084000
Propargyl alcohol 107-19-7 40.00 0.00084000
Southwestern Energy Sand H2O + Disolved Salts 100.00 90.09
Quartz 14808-60-7 100.00 8.93
K Bec Biocide Polyethylene glycol 25322-68-3 60.00 0.01
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00458000
Southwestern Energy Water/Produced Water

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2012 SOUTHWESTERN ENERGY PROD CO 450,743.00 67 0.00 0 0.00 0
2013 SOUTHWESTERN ENERGY PROD CO 1,663,690.00 348 0.00 0 0.00 0
2014 SOUTHWESTERN ENERGY PROD CO 1,155,389.00 364 0.00 0 0.00 0
2015 SWN PROD CO LLC 775,085.00 365 0.00 0 0.00 0
2016 SWN PROD CO LLC 583,419.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 355,997.00 365 0.00 0 0.00 0
2018 SWN PROD CO LLC 218,693.00 335 0.00 0 0.00 0
2019 SWN PROD CO LLC 62,511.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SOUTHWESTERN ENERGY PROD CO Fracturing Fluid Waste (in Tons) 594.98 Tons LANDFILL 101247
2012 SOUTHWESTERN ENERGY PROD CO Drill Cuttings (in Tons) 361.03 Tons LANDFILL THR029
2012 SOUTHWESTERN ENERGY PROD CO Drill Cuttings (in Tons) 1,149.79 Tons LANDFILL 101247
2013 SOUTHWESTERN ENERGY PROD CO Fracturing Fluid Waste (in Tons) 28.93 Tons LANDFILL 101247
2013 SOUTHWESTERN ENERGY PROD CO Produced Fluid (in Barrels) 3,442.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SOUTHWESTERN ENERGY PROD CO Produced Fluid (in Barrels) 487.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Produced Fluid (in Barrels) 345.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 133.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 144.07 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2017 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 307.43 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 31.42 Bbl SURFACE IMPOUNDMENT 826342
2017 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 10.00 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 72.85 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 34.16 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 131.42 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 63.28 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 27.15 Bbl REUSE (AT WELL PAD)
2019 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 47.14 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2121981 Primary Facility 2012-12-05 Routine/Complete Inspection No Violations Noted Well drilled and in production. 5 seperators, 2 condensate tanks onsite. Request cellars no longer be filled with gravel. DEP requesting that gravel be removed from previously drilled wells on location.
2268346 Primary Facility 2014-04-30 Routine/Complete Inspection No Violations Noted
2370801 Primary Facility 2015-05-15 Routine/Complete Inspection No Violations Noted
2536945 Primary Facility 2016-11-09 Site Restoration No Violations Noted
2679392 Primary Facility 2018-01-02 Routine/Complete Inspection No Violations Noted On January 2, 2018, the Department conducted a routine inspection at the SWN Production Company LLC, GU-K-Pad in Stevens Township, Bradford County. The Department was represented by Andrew Hobbins. SWN had several employees on site working on the GPUs during the inspection.

The site sign, E & S plan and inspection logs were on site and available for review. The site was snow covered. PCSM has not been addressed at the site. The Department recommends that SWN continues to follow the schedule and stipulations of the CO&A regarding site restoration.

Seven wells were observed in production during the inspection. The wells were labeled and no bubbling was observed in the well cellars. Two production tanks and seven GPUs were also on site. No staining was observed on the snow covered pad surface. No conductivity readings were taken due to puddles being frozen.

No violations were observed.

2814942 Primary Facility 2018-12-13 Routine/Complete Inspection No Violations Noted Cold/windy at time of inspection

All vents vented to production tanks

For data sources see[7]