37-115-20948

Well Details

Well ID: 37-115-20948
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Jackson Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 152306
Farm/Lease Name: CHARLES 4H
License Status: Active
Spud Date: 2012-07-23
Permit Date: 2012-07-17
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.8781
Longitude: -75.627125

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-04-26 2013-04-26 6940.0 4293912.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Polyethylene Glycol 25322-68-3 60.0 0.01234
Ethoxylated alcohol Proprietary 35.0 0.00031
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.0 0.00617
Short Chained Glycol Ether 112-34-5 50.0 0.00044
Scale Hib A Universal Well Services, Inc. Scale Inhibitor Ethylene Glycol 107-21-1 30.0 0.00319
Sand (Natural) Universal Well Services, Inc. Proppant Silica 14808-60-7 99.9 9.71962
Water N/A Carrier Fluid N/A N/A 100.0 89.9986
Friction Reducer - B Universal Well Services, Inc. Friction Reducer Not Hazardous N/A 100.0 0.09023
EC6116A Universal Well Services, Inc. Biocide Dibromoacetonitrile 3252-43-5 5.0 0.00103
Unihib-G Universal Well Services, Inc. Corrosion Inhibitor Proprietary blend serfactants Proprietary 35.0 0.00031
HCL (15) Universal Well Services, Inc. Formation Damage Removal Hydrochloric Acid 7647-01-0 15.0 0.14974

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2013 SOUTHWESTERN ENERGY PROD CO 821,497.00 218 0.00 0 0.00 0
2014 SOUTHWESTERN ENERGY PROD CO 1,198,126.00 362 0.00 0 0.00 0
2015 SWN PROD CO LLC 866,387.00 365 0.00 0 0.00 0
2016 SWN PROD CO LLC 683,436.00 321 0.00 0 0.00 0
2017 SWN PROD CO LLC 558,068.00 365 0.00 0 0.00 0
2018 SWN PROD CO LLC 413,847.00 365 0.00 0 0.00 0
2019 SWN PROD CO LLC 107,399.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SOUTHWESTERN ENERGY PROD CO Drill Cuttings (in Tons) 1,039.31 Tons LANDFILL 101247
2012 SOUTHWESTERN ENERGY PROD CO Drilling Fluid Waste (in Barrels) 103.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 SOUTHWESTERN ENERGY PROD CO Drill Cuttings (in Tons) 637.64 Tons LANDFILL 101247
2013 SOUTHWESTERN ENERGY PROD CO Fracturing Fluid Waste (in Tons) 48.96 Tons LANDFILL 101247
2013 SOUTHWESTERN ENERGY PROD CO Fracing Fluid Waste (in Barrels) 1,925.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SOUTHWESTERN ENERGY PROD CO Produced Fluid (in Barrels) 4,191.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SOUTHWESTERN ENERGY PROD CO Produced Fluid (in Barrels) 1,723.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Servicing Fluid (in Barrels) 208.75 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Produced Fluid (in Barrels) 869.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Synthetic Liner Materials (in Tons) RWC 806 27.50 Tons LANDFILL 101247
2016 SWN PROD CO LLC Fracturing Fluid Waste (in Barrels) RWC 805 1,402.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 3,627.25 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 172.37 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Fracturing Fluid Waste (in Tons) RWC 805 10.04 Tons LANDFILL 301626
2016 SWN PROD CO LLC Drill Cuttings (in Tons) RWC 810 389.12 Tons LANDFILL 101247
2016 SWN PROD CO LLC Fracturing Fluid Waste (in Tons) RWC 805 46.40 Tons LANDFILL THR029
2017 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 7,694.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 43.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 105.23 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 369.50 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 442.50 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 2,023.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 383.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 3.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2089488 Primary Facility 2012-08-06 Drilling/Alteration No Violations Noted Desoto Rig 8 on site. Drilling out 13 3/8". Drilling top hole section only at this time. Drillers log on site and up to date. Secondary containment in place and in good condition. Well spudded on 7/24/12 with 41' of 20" conductor pipe. 13 3/8" set at 598' anc cemented with 585 sks of Surface Set at 15.85ppg - with 35 bbls cement returns to surface. No violations observed at this time.
2130273 Primary Facility 2013-01-08 Drilling/Alteration No Violations Noted Moving in Desoto Rig 10. Secondary contianment in place. Not bermed completely due to current rig move activities. No violations observed at this time. Permit # posted. Site ID sign in place. No Company man available on site at time of inspection. Will return when drilling begins.
2414203 Primary Facility 2015-10-08 Routine/Complete Inspection No Violations Noted
2431234 Primary Facility 2015-12-07 Routine/Complete Inspection No Violations Noted
2432070 Primary Facility 2015-12-04 Routine/Complete Inspection No Violations Noted Falcon Drilling Rig #25 is currently drilling the Charles 1H in the intermediate section of the well at a depth of (1,525) feet. Gene Tyson is the Company Man on-site. According to Mr. Tyson, casing will be run on this well today and the casing will be cemented at (1,647) feet. The surface casing was set at (603) feet. The well will be drilled to kickoff point at (5,950) feet. Falcon 25 will drill the 2H and 5H wells to kickoff point. The 4H well is in production. SDC Drilling Rig#44 will drill the 1H, 2H and 5H from kickoff point to total depth.
2433464 Primary Facility 2015-12-16 Routine/Complete Inspection No Violations Noted
2436247 Primary Facility 2015-12-23 Routine/Complete Inspection No Violations Noted
2444034 Primary Facility 2016-01-15 Routine/Complete Inspection No Violations Noted
2467265 Primary Facility 2016-03-23 Routine/Complete Inspection No Violations Noted
2472792 Primary Facility 2016-04-08 Routine/Complete Inspection No Violations Noted
2480992 Primary Facility 2016-05-04 Routine/Complete Inspection No Violations Noted
2498566 Primary Facility 2016-07-05 Routine/Complete Inspection No Violations Noted
2503452 Primary Facility 2016-07-21 Routine/Complete Inspection No Violations Noted
2586452 Primary Facility 2017-04-21 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 14:30p.m.

The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge, the valve going to the production tank was closed. There was 495psi on the production casing and 421psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 15:10p.m.

2692091 Primary Facility 2018-02-05 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and was unable to check for gas at the perimeter of the cellar because the gravel was frozen. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2791597 Primary Facility 2018-10-19 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.