37-115-21499

Well Details

Well ID: 37-115-21499
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: New Milford Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 150342
Farm/Lease Name: HUMBERT 5H
License Status: Active
Spud Date: 2014-03-21
Permit Date: 2013-11-18
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.888983
Longitude: -75.703761

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2015-08-06 2015-08-09 6373 5,053,170.0 35616

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Fresh Water Operator Base Fluid Fresh Water 7732-18-5 100 4.95232 42,143,300.0
Hazardous and Non-Hazardous Ingredients Fatty acid ester Confidential 5 0.00000883 76
Polyacrylate Confidential 30 0.00168718 14358
9-Octadecenamide, n,n-bis-2(hydroxy-ethyl)-,(Z) 93-83-4 5 0.00000883 76
Non-hazardous food substance Proprietary 100 0.00001257 107
Ammonium chloride 12125-02-9 10 0.000162166 1380
Inorganic salt Confidential 30 0.00005298 451
Tributyl tetradecyl phosphonium chloride 81741-28-8 10 0.000122518 1043
Polyacrylate Confidential 30 0.00005298 451
Sodium chloride 7647-14-5 30 0.00168718 14358
Hydrochloric acid 7647-01-0 30 0.011235 95608
Water 7732-18-5 100 0.0429691 365659
Organic phosphonate Confidential 10 0.00086653 7374
Alcohols, C12-16, ethoxylated 68551-12-2 10 0.00001766 151
Crystalline silica, quartz 14808-60-7 100 95.0032 808,459,000.0
Hydrotreated light petroleum distillate 64742-47-8 30 0.00174016 14809
BE-9, FR-76, HAI-150E, LP-65 MC,
PermVis VFR-10, SAND-COMMON
WHITE - 100 MESH, SAND-PREMIUM WHITE-30/50
Halliburton Biocide, Corrosion Inhibitor, Friction Reducer, Proppant NA NA 0 0 0
HCl >10% Halliburton Solvent Hydrochloric acid 7647-01-0 0 0 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2015 SWN PROD CO LLC 739,146.00 126 0.00 0 0.00 0
2016 SWN PROD CO LLC 1,565,595.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 764,923.00 364 0.00 0 0.00 0
2018 SWN PROD CO LLC 545,211.00 365 0.00 0 0.00 0
2019 SWN PROD CO LLC 132,179.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 SOUTHWESTERN ENERGY PROD CO Drill Cuttings (in Tons) 833.07 Tons LANDFILL 101247
2014 SOUTHWESTERN ENERGY PROD CO Fracing Fluid Waste (in Barrels) 159.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Drill Cuttings (in Tons) 298.28 Tons LANDFILL 101247
2015 SWN PROD CO LLC Fracing Fluid Waste (in Barrels) 43.60 Bbl LANDFILL THR029
2015 SWN PROD CO LLC Produced Fluid (in Barrels) 13,907.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 3,014.99 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 16.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 21.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 1,246.79 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 352.83 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 104.24 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 2,093.35 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 428.67 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 21.67 Bbl REUSE (AT WELL PAD)
2019 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 3.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 250.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 19.00 Bbl SURFACE IMPOUNDMENT 826342

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2266412 Primary Facility 2014-04-02 Drilling/Alteration No Violations Noted Conductor set
2287696 Primary Facility 2014-07-14 Drilling/Alteration No Violations Noted Falcon Rig# 18 is the active drilling rig on the location. Laddie Pendergraft is the company man on location. The current drilling depth is (3,543) feet. According to Mr. Pendergraft, the vertical section of the Humbert 5H well is being drilled through the process of air drilling. The surface casing was cemented at (613) feet and the intermediate casing was cemented at (1,641). Falcon Rig #18 will drill the vertical section of the well to a total depth of (5,365) feet. This is set to be completed tomorrow morning, 7/15/14. The Humbert 1H well is in the production phase of operations. Fluid level in tank to contain drill cuttings is right at 2' freeboard level. Drilling rig secondary berm behing brine box used for solids control is uneven and not completely secure.
2394932 Primary Facility 2015-08-03 Drilling/Alteration No Violations Noted
2409931 Primary Facility 2015-09-24 Routine/Complete Inspection No Violations Noted
2464428 Primary Facility 2016-03-14 Routine/Complete Inspection No Violations Noted
2481550 Primary Facility 2016-05-04 Routine/Complete Inspection No Violations Noted
2492752 Primary Facility 2016-06-14 Routine/Complete Inspection No Violations Noted
2565648 Primary Facility 2017-02-27 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:00p.m.

The cellar was set up with a plastic corrugated pipe around the well for inspection access; there was water above the surface casing with no bubbling noticed. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure and the valve going to the production tank was closed. There was 573psi on the production casing and 350psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 13:55p.m.

2663875 Primary Facility 2017-11-22 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. The (13x9) and (9x5) annuli were below the water level and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2732630 Primary Facility 2018-05-21 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. No E&S issues were observed. No violations noted.
2765498 Primary Facility 2018-08-21 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a plastic corrugated pipe around the well for inspection access. There was water .5' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2774298 Primary Facility 2018-08-22 Routine/Complete Inspection No Violations Noted The Department arrived on site at 1417 hours to conduct a RTNC inspection. Present to represent the Department were Gene Rickard (WQS) and myself.

The pad surface and access road were stabilized with no apparent erosional issues. All the slopes and berms were well-vegetated and stabilized.

The produced fluid tank and its containment appeared to be in good condition. The GPUs and their containment also appeared to be in good condition, although the containment was about halfway full with stormwater and should be vacuumed out.

The well heads were properly labeled with the name and permit number. No visible bubbling was visible in the well cellars. The entrance to the access road was marked by the required signage. All required paperwork was present in the pad's mailbox.

The Department concluded the inspection and left the site at 1438 hours.

For data sources see[7]

References