X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-21801

Well Details

Well ID: 37-115-21801
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: New Milford Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 148583
Farm/Lease Name: INNES SOUTH 6H
License Status: Active
Spud Date: 2014-07-03
Permit Date: 2014-06-16
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.832011
Longitude: -75.732358

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-11-29 2014-12-02 7010 4,454,020.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 15% HCl Reagent Acid HCL 7647-01-0 15 0.153629 70804.6
AI-600 Weatherford Acid Inhibitor Triethyl Phosphate 78-40-0 7 0.000179234 82.605
Tar bases, quinoline derivs, benzyl chloride-quaternized 72480-70-7 13 0.000332863 153.41
Cinnamaldehyde 104-55-2 10 0.000256049 118.008
Ethoxylated Nonylphenol 68412-54-4 10 0.000256049 118.008
2-Butoxyethanol 111-76-2 7 0.000179234 82.605
Isopropyl Alchol 67-63-0 7 0.000179234 82.605
Ethylene Glycol 107-21-1 60 0.00153629 708.046
N,N-Dimethylformamide 68-12-2 40 0.0010242 472.031
EC6486 Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00276712 1275.31
K Bac -1020 WST Biocide Polyethylene glycol 25322-68-3 60 0.00693124 3194.47
2,2-Diobrom-3nirilopropionamide 10222-01-2 20 0.00231041 1064.82
Sand Keane Sand Crystalline Silica, Quartz 14808-60-7 100 15.8754 7,316,640.0
FRA-405 Clearwater Friction Reducer Petroleum Distillates 64742-47-8 40 0.0258107 11895.6
Sodium Chloride 7647-14-5 10 0.00645268 2973.91
Alcohols, C-12-16, Ethoxylated 68551-12-2 7 0.00451688 2081.74
Ammonium Chloride 12125-02-9 7 0.00451688 2081.74
Water SWN Water / Produced Water H2O + Disolved Salts 7732-18-5 100 83.0126 38,258,800.0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2015 SWN PROD CO LLC 1,519,170.00 329 0.00 0 0.00 0
2016 SWN PROD CO LLC 1,017,005.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 517,652.00 365 0.00 0 0.00 0
2018 SWN PROD CO LLC 565,098.00 365 0.00 0 0.00 0
2019 SWN PROD CO LLC 146,074.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 SOUTHWESTERN ENERGY PROD CO Drill Cuttings (in Tons) 1,350.59 Tons LANDFILL 101247
2014 SOUTHWESTERN ENERGY PROD CO Fracing Fluid Waste (in Barrels) 1,370.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Fracing Fluid Waste (in Barrels) 12.34 Bbl LANDFILL THR029
2015 SWN PROD CO LLC Fracturing Fluid Waste (in Tons) 12.34 Tons LANDFILL THR029
2015 SWN PROD CO LLC Produced Fluid (in Barrels) 5,560.71 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 2,139.74 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 14.29 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 656.30 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 278.44 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 117.12 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 1,120.02 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 238.13 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 10.14 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 248.86 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 17.14 Bbl SURFACE IMPOUNDMENT 826342

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2285173 Primary Facility 2014-07-09 Drilling/Alteration No Violations Noted Well spud 7/3/14 - conductor set. Rig expected to move on location 7/11/14
2299624 Primary Facility 2014-08-26 Routine/Complete Inspection No Violations Noted Falcon Rig# 18 is the active drilling rig on the location. Laddie Pendergraft is the company man on location. The current drilling depth is (4,740) feet. I observed a relatively large hole in the composite mats surveying the drilling rig containment system. Beneath the composite mats are layers of felt and a (40) mil HDPE liner. Mr. Pendergraft said the hole will be repaired today. The secondary containment as part of the drilling rig and associated equipment appeared to be in good condition as well as did the production equipment secondary containment. The fluid levels in the drill cuttings containers and Keystone Landfill containers did not exceed the (2)’ freeboard requirement of Title 25, Env. Protection, Pa. code 78.56.
2300090 Primary Facility 2014-08-28 Drilling/Alteration No Violations Noted
2307275 Primary Facility 2014-09-20 Routine/Complete Inspection No Violations Noted
2329102 Primary Facility 2014-12-15 Incident- Response to Accident or Event No Violations Noted Arrived at the site at 12:00 in response to reported spills of (3-5) barrels of flowback water and (50) gallons of antifreeze. Hydraulic fracturing operations were in progress. Keane Frac is the subcontractor conducting well stimulation (frac) procedures on Innes South 8H well. Justin Phillips, Health, Safety and Environmental Staff Coordinator Supervisor of SWN reported the estimated (3-5) barrel capacity spill flowback water spill that occurred on containment to the Department at 9:30 PM on 12/13/14. Chris Becker, Health, Safety & Environmental staff Coordinator of SWN reported the estimated (50) gallon antifreeze spill to the Department on 12/14/14 at 2:30 PM. There is no evidence the spills escaped secondary containment, no evidence of comprised liner integrity and no evidence of an impact to the pad surface in the general area where the spills occurred. Both spills occurred due to mechanical malfunction according to SWN.
2366974 Primary Facility 2015-05-01 Routine/Complete Inspection No Violations Noted
2452232 Primary Facility 2016-02-23 Routine/Complete Inspection No Violations Noted
2477411 Primary Facility 2016-04-22 Routine/Complete Inspection No Violations Noted
2488538 Primary Facility 2016-05-31 Routine/Complete Inspection No Violations Noted
2559659 Primary Facility 2017-02-06 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:20p.m., the cellar was set up with a plastic corrugated pipe around the well for inspection access and it was about half full of ice. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure and the valve going to the production tank was closed. There was 574psi on the production casing and 505psi on the production line. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 14:10p.m.

2652103 Primary Facility 2017-10-25 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. The (20x13) and (13x9) annuli were below the water level with no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2755274 Primary Facility 2018-07-24 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. There was water .5' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[7]

References