37-117-21421

Well Details

Well ID: 37-117-21421
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Bloss Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 148209
Farm/Lease Name: DCNR 595 24H 50268
License Status: Active
Spud Date: 2012-01-26
Permit Date: 2012-01-18
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.691264
Longitude: -77.112578

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-08-12 2013-08-30 7844 5,590,240.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 7.5% HydroChloric Acid Universal Well Services Acid Hydrochloric Acid HCl 7647-01-0 7.5 0.0646542 0
Bactron K-176 Champion Technologies Biocide Ethanol 64-17-5 5 0.0010849 0
Glutaraldehyde 111-30-8 30 0.00650938 0
Quaternary ammonium compounds,
benzyl-C12-16-

alkyldimethyl, chlorides

68424-85-1 10 0.00216979 0
1-Decanaminium, N-decyl-N,N-dimethyl-, chloride 7173-51-5 10 0.00216979 0
Proppant 80/100 Oklahoma Universal Well Services Proppant Silica 14808-60-7 100 0.653793 0
Gyptron T-390 Champion Technologies Scale Inhibitor Methanol 67-56-1 10 0.00074286 0
Nonylphenol Ethoxylate Proprietary 10 0.00074286 0
FlowPlus DR-5018 Champion Technologies Friction Reducer Sorbitan Monoleate 1338-43-8 5 0.00275219 0
Acrylamide 79-06-1 0.1 0.00005504 0
Hydrotreated Light Distillates 64742-47-8 30 0.0165132 0
Unihib G Universal Well Services Corrosion Inhibitor Glycol Ether 112-34-5 50 0.00016547 0
Ethoxylated Alcohol Proprietary 35 0.00011583 0
Resin Based Nonionic Inhibitor Proprietary 35 0.00011583 0
Iron Stabilizer II Universal Well Services Corrosion Inhibitor Ethylene Glycol 107-21-1 30 0.000391 0
Water Seneca Resources Carrier/Base Fluid Water 7732-18-5 100 91.4149 0
Proppant 30/50 Ottawa Universal Well Services Proppant Silica 14808-60-7 100 3.7725 0
Proppant 40/70 Ottawa Universal Well Services Proppant Silica 14808-60-7 100 4.06059 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2012 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2013 SENECA RESOURCES CO LLC 179,532.00 76 0.00 0 0.00 0
2014 SENECA RESOURCES CO LLC 449,858.80 322 0.00 0 0.00 0
2015 SENECA RESOURCES CO LLC 156,462.94 114 0.00 0 0.00 0
2016 SENECA RESOURCES CO LLC 274,528.00 254 0.00 0 0.00 0
2017 SENECA RESOURCES CO LLC 350,346.51 328 0.00 0 0.00 0
2018 SENECA RESOURCES CO LLC 287,808.10 353 0.00 0 0.00 0
2019 SENECA RESOURCES CO LLC 64,732.04 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SENECA RESOURCES CO LLC Drill Cuttings (in Tons) 700.70 Tons LANDFILL 301358
2013 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) 1,411.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC012
2013 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) 8,426.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) 8,363.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) 14.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC012
2015 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) 811.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) 790.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) RWC 802 436.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) RWC 802 1,335.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) RWC 802 740.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 SENECA RESOURCES CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 19.17 Bbl REUSE (AT WELL PAD)
2017 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) RWC 802 1,406.42 Bbl REUSE (AT WELL PAD)
2017 SENECA RESOURCES CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 106.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) RWC 802 1,330.58 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) RWC 802 8.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) RWC 802 718.32 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 44.17 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) RWC 802 748.34 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) RWC 802 2.79 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) RWC 802 60.00 Bbl REUSE (AT WELL PAD)
2019 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) RWC 802 65.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Produced Fluid (in Barrels) RWC 802 21.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC003

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2061725 Primary Facility 2012-04-20 Routine/Complete Inspection No Violations Noted
2068773 Primary Facility 2012-04-30 Compliance Evaluation No Violations Noted
2069034 Primary Facility 2012-05-16 Routine/Complete Inspection No Violations Noted drilling 21 H
2085068 Primary Facility 2012-07-12 Routine/Complete Inspection No Violations Noted
2199675 Primary Facility 2013-08-29 Routine/Complete Inspection No Violations Noted
2201986 Primary Facility 2013-09-04 Incident- Response to Accident or Event No Violations Noted Fracking the 6 gas wells. Hydraulic oil spill reported (50 gal)
2219838 Primary Facility 2013-10-17 Routine/Complete Inspection No Violations Noted
2235889 Primary Facility 2014-01-07 Routine/Partial Inspection No Violations Noted 6 gas wells producing. Pad ice covered today
2292702 Primary Facility 2014-07-23 Follow-up Inspection No Violations Noted
2481933 Primary Facility 2016-05-04 Routine/Partial Inspection No Violations Noted 6 Marcellus Shale wells producing natural gas. Groundwater monitoring well also on pad.
2609234 Primary Facility 2017-06-27 Routine/Complete Inspection Violation(s) Noted Six Wells in production phase. Six water separators located with in containment. No leaks detected from production equipment. The wellsite restoration report is not on file for the site. Site not restored. No active drilling permits for the DCNR 595 C at the time of this this inspection.
2820359 Primary Facility 2018-12-26 Site Restoration No Violations Noted NOT denied. Filter sock (photos 1 & 3) is considered a temporary E & S control; ESCGP termination requires "permanent stabilization" and removal of temporary E & S controls.

I did not take electrical conductivity from pooled water on site, because it is all frozen. Air temp: 32F JLP

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2609234 789329 2017-06-27 2018-02-09 OGA3216(A) Environmental Health & Safety My inspection revealed that you failed to restore the DCNR 595 Tract C site after the completion of drilling. This is a violation of the Oil and Gas Act, 58 P.S. section 3216 (a) which provides: A) General rule. Each oil and gas well owner or operator shall restore the land service within the area d
2609234 789330 2017-06-27 2018-02-09 78a65(a)1 Environmental Health & Safety Failure to minimize and restore the well site. This site is not in compliance with the restoration schedule submitted to the DEP by Seneca.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
789329 354722 NOV - Notice of Violation 2018-02-09
789330 354722 NOV - Notice of Violation 2018-02-09

For data sources see[7]

References