37-117-21817

Well Details

Well ID: 37-117-21817
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Sullivan Township
Operator Name: SWEPI LP
Well Pad ID: 149430
Farm/Lease Name: THOMAS 503 2H
License Status: Active
Spud Date: 2016-08-11
Permit Date: 2015-11-05
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.834444
Longitude: -76.964667

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2016-12-12 2016-12-15 5734 2,281,310.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand U.S. Well Services, LLC Proppant Crystalline Silica, quartz 14808-60-7 100 24.7985 6,371,820.0
HCL Acid (12.6%-17.5%) U.S. Well Services, LLC Bulk Acid Water 7732-18-5 87.4 0.89272 229379
Hydrogen Chloride 7647-01-0 17.5 0.20756 53330.1
AI-303 U.S. Well Services, LLC Acid Corrosion Inhibitors Ethylene glycol 107-21-1 40 0.0003 77.7588
Cinnamaldehyde 104-55-2 20 0.00011 28.1128
Formic acid 64-18-6 20 0.00011 27.1884
Butyl cellosolve 111-76-2 20 0.0001 24.4967
Polyether 60828-78-6 10 0.00005000 13.5942
Acetophenone,thiourea,formaldehyde polymer 68527-49-1 5 0.00003000 6.7971
K-BAC 1020 U.S. Well Services, LLC Anti-Bacterial Agent 2,2-dibromo-3-nitrilopropionamide 10222-01-2 20 0.00813 2089.1
Deionized Water 7732-18-5 28 0.00464 1193.29
WFRC-2100 U.S. Well Services, LLC Friction Reducer Alcohol Ethoxylate 68551-12-2 5 0.00454 1167.6
Cationic copolymer of acrylamide 69418-26-4 30 0.00327 840
Hydrotreated Petroleum Distillates 64742-47-8 30 0.02208 5674.54
SI-1200 U.S. Well Services, LLC Scale Inhibitor Ammonia 7664-41-7 0.5 0.00013 33.6869
Ethylene Glycol 107-21-1 40 0.0098 2518.81
Water Shell Carrier/Base Fluid Water 7732-18-5 100 74.0479 19,026,200.0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 SWEPI LP 0.00 0 0.00 0 0.00 0
2017 SWEPI LP 1,306,702.17 346 0.00 0 0.00 0
2018 SWEPI LP 826,532.12 365 0.00 0 0.00 0
2019 SWEPI LP 166,541.85 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2016 SWEPI LP Drill Cuttings (in Tons) RWC 810 583.80 Tons REUSE OTHER THAN ROAD SPREADING
2016 SWEPI LP Produced Fluid (in Barrels) RWC 802 773.33 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWEPI LP Synthetic Liner Materials (in Tons) RWC 806 11.21 Tons LANDFILL 301358
2017 SWEPI LP Produced Fluid (in Barrels) RWC 802 832.47 Bbl REUSE (AT WELL PAD)
2017 SWEPI LP Produced Fluid (in Barrels) RWC 802 38.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017 SWEPI LP Waste Water Treatment Sludge (in Tons) RWC 804 26.41 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 SWEPI LP Unused Fracturing Fluid Waste (in Barrels) RWC 805 250.00 Bbl REUSE (AT WELL PAD)
2017 SWEPI LP Unused Fracturing Fluid Waste (in Barrels) RWC 805 2,199.96 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018 SWEPI LP Produced Fluid (in Barrels) RWC 802 692.50 Bbl REUSE (AT WELL PAD)
2018 SWEPI LP Produced Fluid (in Barrels) RWC 802 125.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2019 SWEPI LP Produced Fluid (in Barrels) RWC 802 66.66 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2509354 Primary Facility 2016-08-10 Preoperation Inspection No Violations Noted Three cellars dug on ~3.3 acre pad on top of hill. Well vegetated slopes.
2563406 Primary Facility 2017-02-21 Routine/Complete Inspection No Violations Noted
2594841 Primary Facility 2017-05-17 Routine/Partial Inspection No Violations Noted EC reading w Oakton PCSTestr 35: production tank containment--2.2 mS/cm, basin--0.20 mS/cm.

A 3 man crew is on site coating some of the production line w primer. A vac truck and driver are also on site. On site ~1305-1425.

2708161 Primary Facility 2018-03-21 Routine/Partial Inspection No Violations Noted SWEPI inspection log in mailbox near site ID sign; last inspection listed on March 18, 2018. I got a 0.34 mS/cm electrical conductivity reading with an Oakton PCSTestr 35 from a puddle the pad (broke thru ice on top). Air temp 32F. JLP
2852344 Primary Facility 2019-03-12 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of SWEPI's Thomas 503 well site in Rutland & Sullivan Twps, Tioga County on 3/12/2019 at 1250 hours. The weather was 30 degrees and partly cloudy. The act 9 sign was observed at the site entrance along with the site's E&S Plan which was in the mailbox. The onsite inspection log was in the mailbox by the entrance. Company personnel last inspected the site on 3/3/2019 and noted no issues.

There is currently 3 Marcellus wells onsite (2H, 4H, & 6H). Parts of the site have been recently reclaimed. The infiltration berm to the east, reclaimed portion of the pad to the north, and the reclaimed pony pad all looked good today. No erosional issues were noted. All disturbed areas have silt sock lined downgrade of them. The constructed areas all matched the site restoration plan. Containment structures were intact and functioning, no evidence of spills or releases was noted. Areas of the pad not recently disturbed are well vegetated and stabilized.

No violations noted today, I de

For data sources see[7]