If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-019-22697 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.880494,"lon":-79.978133,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Butler | |
Municipality: Connoquenessing Township | |
Operator Name: XTO ENERGY INC | |
Well Pad ID: 154247 | |
Farm/Lease Name: LESNEY UNIT 5H | |
License Status: Active | |
Spud Date: 2018-01-24 | |
Permit Date: 2017-11-16 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 40.880494 | |
Longitude: -79.978133 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2018-04-20 | 2018-05-04 | 5554 | 25,407,500.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | CI-3 | C&J Energy Services | Acid Corrosion Inhibitors | Listed Below | Listed Below | 0 | 0 | 0 |
Water | XTO Energy/ExxonMobil | Carrier Fluid | Water | 7732-18-5 | 100 | 91.252 | 0 | |
BIO-CLEAR 2000 | C&J Energy Services | Biocides | Listed Below | Listed Below | 0 | 0 | 0 | |
Tar Bases, Quinoline Derivs. | 68513-87-1 | 1 | 0.00001300 | 0 | ||||
Iron Oxide | 1309-37-1 | 0.1 | 0.002725 | 0 | ||||
2,2-Dibromo-3-nitrilo-propionamide (DBNPA) | 10222-01-2 | 30 | 0.006397 | 0 | ||||
Crystalline Silica, quartz | 14808-60-7 | 99.9 | 1.47243 | 0 | ||||
Ammonium Chloride | 12125-02-9 | 2 | 0.000385 | 0 | ||||
Crystalline Silica, quartz | 14808-60-7 | 99.9 | 3.73772 | 0 | ||||
Hydrochloric Acid | 7647-01-0 | 7.5 | 0.052249 | 0 | ||||
Methanol | 67-56-1 | 1 | 0.000192 | 0 | ||||
Iron Oxide | 1309-37-1 | 0.1 | 0.003741 | 0 | ||||
Sodium Acetate Anhydrous | 127-09-3 | 3 | 0.00208 | 0 | ||||
Cinnamaldehyde | 104-55-2 | 15 | 0.000188 | 0 | ||||
Dimethylformamide | 68-12-2 | 20 | 0.000251 | 0 | ||||
Sorbitan Monooleate | 1338-43-8 | 2 | 0.001387 | 0 | ||||
2-Propenamide as residual | 79-06-1 | 0.1 | 0.00006900 | 0 | ||||
Polyethylene glycol | 25322-68-3 | 50 | 0.010662 | 0 | ||||
Titanium Oxide | 13463-67-7 | 0.1 | 0.003741 | 0 | ||||
Ethylene Glycol | 107-21-1 | 40 | 0.000501 | 0 | ||||
1-OCTANOL | 111-87-5 | 2.5 | 0.00003100 | 0 | ||||
Water | 7732-18-5 | 30 | 0.0208 | 0 | ||||
Ethylene Glycol | 107-21-1 | 5 | 0.003467 | 0 | ||||
Titanium Oxide | 13463-67-7 | 0.1 | 0.002725 | 0 | ||||
Ethoxylated Sorbitan Monooleate | 9005-65-6 | 1 | 0.000693 | 0 | ||||
Tar bases, quinoline derivs, benzyl chloride-quaternized | 72480-70-7 | 15 | 0.000188 | 0 | ||||
CJENERGY-Phosphate-00040 | Proprietary | 6 | 0.001155 | 0 | ||||
Water | 7732-18-5 | 92.5 | 0.644401 | 0 | ||||
Water | 7732-18-5 | 28.5 | 0.006077 | 0 | ||||
Alcohols, C12-15-branched and linear, ethoxylated propoxylated |
120313-48-6 | 2 | 0.001387 | 0 | ||||
Poly(oxy-1,2-ethanediyl),alpha-(4-nonylphenyl)-omega hydroxy-, branched |
127087-87-0 | 5 | 0.00006300 | 0 | ||||
Poly(oxy-1,2-ethandiyl), alpha-isodecyl-omega-hydroxy-phosphat e |
108818-88-8 | 2 | 0.001387 | 0 | ||||
Aluminum Oxide | 1344-28-1 | 1.1 | 0.041156 | 0 | ||||
Aluminum Oxide | 1344-28-1 | 1.1 | 0.029973 | 0 | ||||
Titanium Oxide | 13463-67-7 | 0.1 | 0.001474 | 0 | ||||
Distillates (Petroleum), Hydrotreated Light | 64742-47-8 | 35 | 0.024266 | 0 | ||||
Isopropanol | 67-63-0 | 2.5 | 0.00003100 | 0 | ||||
2-Butoxyethanol | 111-76-2 | 15 | 0.000188 | 0 | ||||
Water | 7732-18-5 | 30 | 0.000376 | 0 | ||||
Aluminum Oxide | 1344-28-1 | 1.1 | 0.016213 | 0 | ||||
Crystalline Silica, quartz | 14808-60-7 | 99.9 | 2.72211 | 0 | ||||
2-Propenoic acid, polymer with 2-propenamide, sodium salt | 25987-30-8 | 30 | 0.0208 | 0 | ||||
Water | 7732-18-5 | 96 | 0.018478 | 0 | ||||
1-DECANOL | 112-30-1 | 5 | 0.00006300 | 0 | ||||
Iron Oxide | 1309-37-1 | 0.1 | 0.001474 | 0 | ||||
Monoethanolamine hydrochloride | 2002-24-6 | 2 | 0.000385 | 0 | ||||
Triethyl Phosphate | 78-40-0 | 2.5 | 0.00003100 | 0 | ||||
Sand | C&J Energy Services | Sand - Bulk - Pennsylvania | Listed Below | Listed Below | 0 | 0 | 0 | |
FR-16 | C&J Energy Services | Friction Reducer | Listed Below | Listed Below | 0 | 0 | 0 | |
SI-6 PA-Only | C&J Energy Services | PA-Proprietary | Listed Below | Listed Below | 0 | 0 | 0 | |
HC-7.5 | C&J Energy Services | Bulk Acid | Listed Below | Listed Below | 0 | 0 | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2018 | XTO ENERGY INC | 346,377.24 | 128 | 0.00 | 0 | 3,085.81 | 122 |
2019 | XTO ENERGY INC | 456,808.04 | 90 | 0.00 | 0 | 3,164.16 | 90 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2018 | XTO ENERGY INC | Produced Fluid (in Barrels) RWC 802 | 5,225.00 Bbl | REUSE (AT WELL PAD) | |
2018 | XTO ENERGY INC | Other Oil & Gas Wastes (in Tons) RWC 899 | 0.04 Tons | RESIDUAL WASTE PROCESSING FACILITY | 101674 |
2018 | XTO ENERGY INC | Drill Cuttings (in Tons) RWC 810 | 1,207.43 Tons | LANDFILL | 100585 |
2018 | XTO ENERGY INC | Drilling Fluid Waste (in Barrels) RWC 803 | 1,100.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018 | XTO ENERGY INC | Waste Water Treatment Sludge (in Tons) RWC 804 | 49.64 Tons | RESIDUAL WASTE PROCESSING FACILITY | 101674 |
2018 | XTO ENERGY INC | Other Oil & Gas Wastes (in Barrels) RWC 899 | 125.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018 | XTO ENERGY INC | Synthetic Liner Materials (in Tons) RWC 806 | 64.82 Tons | LANDFILL | 100434 |
2018 | XTO ENERGY INC | Produced Fluid (in Barrels) RWC 802 | 24,009.11 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018 | XTO ENERGY INC | Synthetic Liner Materials (in Tons) RWC 806 | 34.79 Tons | LANDFILL | 100585 |
2018 | XTO ENERGY INC | Unused Fracturing Fluid Waste (in Tons) RWC 805 | 14.49 Tons | LANDFILL | 100434 |
2018 | XTO ENERGY INC | Produced Fluid (in Barrels) RWC 802 | 4,117.20 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2018 | XTO ENERGY INC | Produced Fluid (in Barrels) RWC 802 | 843.56 Bbl | INJECTION DISPOSAL WELL | 34-133-24189 |
2018 | XTO ENERGY INC | Produced Fluid (in Barrels) RWC 802 | 544.00 Bbl | INJECTION DISPOSAL WELL | 34-133-21076 |
2018 | XTO ENERGY INC | Produced Fluid (in Barrels) RWC 802 | 120.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20114 |
2019 | XTO ENERGY INC | Produced Fluid (in Barrels) RWC 802 | 1,384.96 Bbl | INJECTION DISPOSAL WELL | 34-133-21076 |
2019 | XTO ENERGY INC | Produced Fluid (in Barrels) RWC 802 | 8,066.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2019 | XTO ENERGY INC | Produced Fluid (in Barrels) RWC 802 | 2,378.67 Bbl | INJECTION DISPOSAL WELL | 34-133-24189 |
2019 | XTO ENERGY INC | Produced Fluid (in Barrels) RWC 802 | 4,876.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2684628 | Primary Facility | 2018-01-22 | Administrative/File Review | No Violations Noted | |
2687369 | Primary Facility | 2018-01-25 | Routine/Partial Inspection | No Violations Noted | At the time of inspection, Lightning Energy Services was onsite with a Soilmec auger rig. They were circulating in mouse holes. Cellar has been set. Well was partially covered with a steel plate while mouse hole was being set. The Pawlowicz well was surrounded with a steel cage. Emergency Response sign and permit sign is correctly posted at the lease access entrance. |
2690721 | Primary Facility | 2018-02-05 | Administrative/File Review | No Violations Noted | |
2690857 | Primary Facility | 2018-02-05 | Administrative/File Review | No Violations Noted | |
2692933 | Primary Facility | 2018-02-05 | Routine/Partial Inspection | No Violations Noted | At the time of inspection, rig is onsite , but has been laid down. Well was covered with a steel plate. Most of equipment remained onsite and is on containment. Toolpusher said they'll be moving rig to Ohio. Surface casing was cemented using 435 sxs Class A (94 bbls), 2% Gypsum, 2% CaCl2, 15.6 ppg, 1.22 yield. Displaced with 76 bbls water and landed plug. Floats held and 22 bbls cement returned to surface. A float shoe and collar were used with 4 centralizers.
Intermediate casing was cemented using 670 sxs Class A (146 bbls), 2% Gypsum, 2% CaCl2, 15.6 ppg, 1.22 yield. Displaced with 154 bbls water. Did not bump plug. Floats held and 25 bbls cement returned to surface. A float shoe and collar were used with 16 centralizers. |
2702978 | Primary Facility | 2018-03-09 | Administrative/File Review | No Violations Noted | |
2706599 | Primary Facility | 2018-03-19 | Administrative/File Review | No Violations Noted | |
2709305 | Primary Facility | 2018-03-15 | Drilling/Alteration | No Violations Noted | At the time of inspection, 5 1/2" was being unloaded from trucks. Nomac 79 was onsite drilling production hole. BOP had been tested on 3/10 and passed. Chemicals were all contained and there were no apparent rips, tears, or holes in containment. |
2709543 | Primary Facility | 2018-03-19 | Routine/Partial Inspection | No Violations Noted | At the time of inspection, Nomac 79 was rigging down and will be moving to the Briston pad. Production casing was cemented using a lead of 400 sxs 35:65 Poz Class H (79 bbls), 15.2 ppg, 1.1 yield and tail of 1685 sxs Class H, 35% Acid Soluble (470 bbls), 15.6 ppg, 1.57 yield. Pumped 335 bbls water and plug landed. Floats held. 10 bbls spacer to surface and top of cement estimated to be at 2165'. |
2718425 | Primary Facility | 2018-04-16 | Administrative/File Review | No Violations Noted | |
2723389 | Primary Facility | 2018-04-26 | Administrative/File Review | No Violations Noted | |
2727814 | Primary Facility | 2018-05-09 | Routine/Partial Inspection | No Violations Noted | On 5/9/2018, WQS Brian MacQuarrie onsite, meet with Shawn Gearhart- XTO Energy. Currently the plugs are being drilled out on the Lesney 5H. The well site consists of two wells; the Palowicz 4H-019-22583 (currently shut in) and the Lesney 5H-019-22697. Erosion and Sedimentation plan and E/S inspection reports in mailbox. Site sign maintained at entrance. Erosion and Sedimentation BMPs installed and maintained. |
2737133 | Primary Facility | 2018-06-04 | Administrative/File Review | No Violations Noted | |
2742848 | Primary Facility | 2018-06-19 | Administrative/File Review | No Violations Noted | |
2748878 | Primary Facility | 2018-07-05 | Routine/Partial Inspection | No Violations Noted | On 7/5/2018, WQS Brian MacQuarrie onsite. The well site consists of two wells; the Palowicz 4H-019-22583 and the Lesney 5H-019-22697 in production. Erosion and Sedimentation plan and E/S inspection reports in mailbox. Site sign maintained at entrance. Compost filter sock removed and placed in a pile on well pad. Vegetative growth established in previously disturbed areas. |
2753671 | Primary Facility | 2018-07-19 | Administrative/File Review | No Violations Noted | |
2812617 | Primary Facility | 2018-12-06 | Routine/Partial Inspection | No Violations Noted | On 12/6/2018, WQS Brian MacQuarrie onsite. Post Drilling Site Restoration report received for WellAPI 019-22697. All equipment not necessary for production removed from site. Site consists of two wells (4H-019-22583 and 5-019-22697). Tank battery consists of three 400 bbl tanks installed within secondary steel containment structure. Other production equipment includes two GPUs and TVO. Well site vegetated. Infiltration pond maintained. |
For data sources see[7]