If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-021-21205 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.627828,"lon":-78.748447,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Cambria | |
Municipality: West Carroll Township | |
Operator Name: NTS ENERGY LLC | |
Well Pad ID: | |
Farm/Lease Name: FORD NTS FORD 1 | |
License Status: | |
Spud Date: | |
Permit Date: 2015-03-09 | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Latitude: 40.627828 | |
Longitude: -78.748447 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2015 | NTS ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | NTS ENERGY LLC | 930.00 | 120 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2016 | NTS ENERGY LLC | Produced Fluid (in Barrels) RWC 802 | 50.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2365536 | Primary Facility | 2015-04-28 | Drilling/Alteration | No Violations Noted | Well Id sign and E&S plan were present at access road. At the time of the inspection, no E&S concerns and no freeboard issues were present at the site. NTS contracted Whipstock to complete the gas well. Conductor pipe (20”) was set at 40 ft. and was sanded in. 9 5/8” pipe was set at 399 feet. On 4/28/15, cement of pipe was completed with 135 sks of Type I and 8 bbl. return. C&J Energy performed cement project. Water was recorded at 290 feet and coal was recorded at 63 ft. Current depth was 430 feet. |
2365568 | Primary Facility | 2015-04-28 | Complaint Inspection | No Violations Noted | DEP personnel, Paul Wyrwas and Jason Brannon inspected complaint of water notice. DEP met property owner. Complainant was not home. Property owner was concern that drilling adjacent to his property will affect his potable water source and was not notified of drilling. As per regulation, all property owners with potable wells were sampled and notified of drilling activity. Currently, the property owner resident home and adjacent trailer were approximately 2500 feet from gas well. DEP and owner walked to resident’s water source to take a GPS reading. Based on location on directions of owner, a location of N 40^ 37.673’ and W 78^45.207’ was recorded at point source. Based on this location, the source was 1900 feet from the gas well. Property was also recorded several ponds and springs on property located on the hillside of the resident with water flow to the pond and surface stream located on the hillside. |
2365575 | Primary Facility | 2015-04-29 | Routine/Complete Inspection | No Violations Noted | Well Id sign and E&S plan were present at access road. At the time of the inspection, no E&S concerns and no freeboard issues were present at the site. NTS contracted Whipstock to complete the gas well. Conductor pipe (20”) was set at 40 ft. and was sanded in. 9 5/8” pipe was set at 399 feet. 7” pipe was set at 910 feet. On 4/29/15, cement of pipe was completed with 180 sks of Class AI and 6 bbl. return. C&J Energy performed cement project. Water was recorded at 290 feet and coal was recorded at 63 ft. Current depth was 940 feet. Plug was down at 11:58 hrs. Anticipated depth is 3900 feet. |
2368368 | Primary Facility | 2015-04-29 | Routine/Complete Inspection | Violation(s) Noted | On-site inspection in response to spud notification for 4/27/2015.At time of inspection, drill rig on-site. Site ID sign present. Valid drilling permit posted. E&S plan on-site.Per on-site plan, Operator representative made “field changes” to E&S plan previously prepared by certified engineer. Changes include the addition of access road culverts, substitution of BMPs, the location of the access road, and potentially the location of the wellhead.Beginning of shared access road rocked and in good condition.Beginning of access road has been re-located per changes made to the E&S plan by Operator representative.Culverts not identified on the E&S plan have been installed in several locations along the access road and are not equipped with adequate outlet protection.Silt fence with hay bales have been installed in place of compost sock as identified on the E&S plan. Silt fence is not properly installed and/or maintained.**ADDITIONAL COMMENTS ON PAPER SAIR** |
2368606 | Primary Facility | 2015-05-05 | Drilling/Alteration | No Violations Noted | Well Id sign and E&S plan were present at access road. At the time of the inspection, no E&S concerns and no freeboard issues were present at the site. NTS contracted Whipstock to complete the gas well. Conductor pipe (20”) was set at 46 ft. and was sanded in. 13 3/8” pipe was set at 107 feet. A void was encountered at 56 feet approximately 2’. Cement of pipe was completed with 75 sks of Class A and 0 bbl. return. Cement was completed to surface. C&J Energy performed cement project. Current depth was 120 feet. Plug was down at 8:30 hrs. Anticipated depth is 3900 feet. |
2368607 | Primary Facility | 2015-05-06 | Drilling/Alteration | No Violations Noted | Well Id sign and E&S plan were present at access road. At the time of the inspection, no E&S concerns and no freeboard issues were present at the site. NTS contracted Whipstock to complete the gas well. Conductor pipe (20”) was set at 46 ft. and was sanded in. 13 3/8” pipe was set at 107 feet. 7” pipe was set at 910’. Cement of pipe was completed with 150 sks of Class A and 3 bbl. return. C&J Energy performed cement project. Current depth was 922 feet. Plug was down at 13:45 hrs. Anticipated depth is 3900 feet. |
2371778 | Primary Facility | 2015-05-11 | Routine/Partial Inspection | Violation(s) & Outstanding Violations | RTPT inspt conducted as follow-up to inspection record 2368368 in which Operator representative Steve Phillips moved the location of the drilled well on the E&S plan from the permitted well location identified on the E&S plan by a certified engineer. |
2376835 | Primary Facility | 2015-06-01 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | On-site FUI conducted in response to viols issued under inspection record 2368368 (enf ID 323048).At time of inspt, well drilled, but not yet equipped for production.Viols previously issued under inspection record 2371778 (enf ID 323515) remain outstanding.Previously requested seasonal high groundwater table data (inspection record 2368368) not yet received by Dept.AR culverts remain un-equipped with adequate outlet protection.One lined below-grade drill pit on-site. Pit remains structurally compromised.The on-site Control and Disposal Plan remains unidentified, inadequate, and continues to be non-compliant with current regulations.Requested written responses to vios issued under inspt records 2368368, 2371778 not yet received by Dept.Viols issued under inspt records 2368368, 2371778 (enf IDs 323048, 323515) remain outstanding.Environ'l Trainee C. Witham present during inspt.**Add'l comments on paper SAIR** |
2376955 | Primary Facility | 2015-05-26 | Administrative/File Review | Outstanding Violations - No Viols Req'd | Admin inspt. Department contacted Operator representative Steve Phillips via phone to discuss violations issued under under inspection record 2371778 (enf ID 323515) for failure to drill the well in the exact location as identified on the permitted well plat. |
2392134 | Primary Facility | 2015-07-23 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | On-site FUI conducted in response to violations issued under inspection record 2368368 (enf ID 323048).ARculverts remain un-equipped with adequate outlet protection.Silt fence remains improperly installed and/or maintained.Unidentified earth disturbance down-gradient of perimeter BMPs and disturbed perimeters of well pad nearing 70% uniform and adequate vegetative growth.One lined below-grade drill pit remains on-site. Pit remains structurally compromised with liner closest to wellhead beginning to fall in. Orange security fence around pit is structurally compromised.On-site C&D Plan remains unidentified and inadequate and continues to be non-compliant with current regs.Previously requested seasonal high groundwater table data (inspection record 2368368) not received by the Dept. Requested written responses to viols not received by the Dept.Viols remain outstanding. |
2395775 | Primary Facility | 2015-07-29 | Administrative/File Review | Outstanding Violations - No Viols Req'd | Admin inspection conducted in response to violations issued under inspection record 2371778 (enf ID 323515) for failure to drill the well in the exact location as identified on the permitted well plat. |
2468380 | Primary Facility | 2016-03-23 | Routine/Complete Inspection | No Violations Noted | gas well in production. no issues. |
2500751 | Primary Facility | 2016-07-12 | Routine/Complete Inspection | No Violations Noted | system running. no issues |
2532283 | Primary Facility | 2016-10-17 | Routine/Complete Inspection | No Violations Noted | system running. noi issues |
2603815 | Primary Facility | 2017-06-01 | Routine/Complete Inspection | No Violations Noted | system running. no issues |
2678236 | Primary Facility | 2018-01-04 | Routine/Complete Inspection | No Violations Noted | System running no issues. Well tag present. Emergency contact sign present. |
2713044 | Primary Facility | 2018-04-02 | Routine/Complete Inspection | No Violations Noted | Well tag and emergency contact number present at the site. No issues at the site |