37-081-20365

Well Details

Well ID: 37-081-20365
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Penn Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 147842
Farm/Lease Name: BOWER UNIT 6H
License Status: Active
Spud Date: 2011-04-06
Permit Date: 2010-09-15
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.281244
Longitude: -76.631217

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-10-11 2011-10-11 7365.00 4,466,120.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 DWP-972 Calfrac Well Services Oxygen Scavenger Sodium thiosulfate 7772-98-7 31.00 0.01
Sand (Proppant) Calfrac Well Services Propping Agent Quartz 14808-60-7 99.90 13.65
Water Base Fluid Water 100.00 85.44
DWP-944 Calfrac Well Services Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 40.00 0.01
Polyethylene glycol 25322-68-3 70.00 0.02
DAP-923 Calfrac Well Services Corrosion Inhibitor Fatty acids, tall-oil 61790-12-3 30.00 0.00037000
Ethoxylated C14-15 alcohols 68951-67-7 30.00 0.00037000
Alkenes, C>10 .alpha.- 64743-02-8 5.00 0.00006000
Thiourea polymer 68527-49-1 30.00 0.00037000
Methanol 67-56-1 60.00 0.00074000
Propargyl alcohol 107-19-7 10.00 0.00012000
3 HCl Acid Calfrac Well Services Perforation Breakdown Hydrochloric acid 7647-01-0 100.00 0.69
DAP-103 Calfrac Well Services Iron Control Citric acid 77-92-9 60.00 0.00307000
DAP-901 Calfrac Well Services Scale Inhibitor Phosphoric acid ammonium salt 5.00 0.00090000
Methanol 67-56-1 30.00 0.00540000
Ammonium chloride 12125-02-9 10.00 0.00180000
Amine salt 5.00 0.00090000
Organic phosphonate 30.00 0.00540000
Oxyalkylated polyamine 5.00 0.00090000
DWP-612 Calfrac Well Services Friction Reducer No Hazardous Materials 100.00 0.08

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 170,395.00 309 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 163,920.00 365 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 153,195.00 365 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 147,655.00 306 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 107,305.00 270 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 121,242.00 337 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 127,787.00 364 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 30,235.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 EXCO RESOURCES PA LLC Fracing Fluid Waste (in Barrels) 8,203.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 307.12 Bbl STORAGE PENDING DISPOSAL OR REUSE
2012 EXCO RESOURCES PA LLC Fracturing Fluid Waste (in Tons) 111.64 Tons LANDFILL 301358
2012 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 8,943.15 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 109.52 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EXCO RESOURCES PA LLC Drill Cuttings (in Tons) 5.81 Tons LANDFILL 301358
2013 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 652.34 Bbl STORAGE PENDING DISPOSAL OR REUSE
2013 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 780.86 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 328.56 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC009
2013 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 2,245.16 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 109.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC024
2014 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 285.50 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 351.60 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2014 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 369.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC024
2014 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 88.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2014 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 848.20 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 1,188.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 88.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2015 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 176.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC009
2015 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 219.80 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) 2,026.70 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2016 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) RWC 802 2,129.40 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) RWC 802 1,989.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) RWC 802 1,720.90 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) RWC 802 147.40 Bbl REUSE (AT WELL PAD)
2018 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) RWC 802 368.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 EXCO RESOURCES PA LLC Produced Fluid (in Barrels) RWC 802 397.60 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1979986 Primary Facility 2011-06-13 Drilling/Alteration No Violations Noted
1985134 Primary Facility 2011-06-27 Routine/Partial Inspection No Violations Noted
1997759 Primary Facility 2011-08-22 Drilling/Alteration Violation(s) Noted
2043854 Primary Facility 2012-02-17 Routine/Complete Inspection No Violations Noted
2044676 Primary Facility 2012-02-21 Routine/Complete Inspection Outstanding Violations - No Viols Req'd
2055068 Primary Facility 2012-03-29 Follow-up Inspection Outstanding Violations - No Viols Req'd
2055076 Primary Facility 2012-03-26 Follow-up Inspection Outstanding Violations - No Viols Req'd
2074197 Primary Facility 2012-06-06 Routine/Complete Inspection No Violations Noted
2110584 Primary Facility 2012-10-24 Routine/Complete Inspection No Violations Noted
2437889 Primary Facility 2015-12-30 Routine/Complete Inspection No Violations Noted Arrived @ 13:15. Weather: foggy, cloudy, some fine drizzle5 wells, formerly in production, were shut-in. All well cellars were filled with gravel. There were two open annular vents at each well. The 13-3/8” x 9-5/8” was vented with a 1” pipe. The 9-5/8” x 5-1/2” annulus was vented with a 2” pipe. The annuli were monitored with an Altair 5X gas meter calibrated on 12/28/15.
2543944 Primary Facility 2016-12-08 Routine/Complete Inspection No Violations Noted Routine Inspection; 12/8/2016. I entered the location at 10:06 and began the inspection. At the time of the inspection, the Bower Unit 1H (081-20149, 2H (081-20361), 3H (081- 20362), 4H (081-20456), and 6H (081-20356) wells were in production. The well pad area was well vegetated and can be considered permanently stabilized. The well site has not been restored and the Well Site Compliance Information Request reply (submitted 9/21/2015) says the pad was reclaimed and the Notice of Termination was to be submitted in September of 2015. The well pad remains at its original size and the site currently does not conform to the permitted restoration plan. The original E&S permit has been expired since 10/16/2014.

The Department considers a well site to be restored under Section 3216(c) of the 2012 Oil and Gas Act when the oil or gas owners or operators meet the following:

1. All permanent post construction stormwater control features as identified in the Post Construction Stormwater Management/Site Restoratio
2694626 Primary Facility 2018-02-14 Routine/Complete Inspection No Violations Noted Weather was 30° and cloudy at time of inspection. Well had a digital pressure gauge attached above the swab valve for the tubing and attached to the 5 1/2 casing valve. Pressure on the tubing was 211 psi at time of inspection. The digital gauge on the 5 1/2 casing was not functioning at time of inspection. An analog gauge read approximately 310 psi for the casing. There were three annulus vents plumbed to surface. The 5 1/2 x 9 5/8 annulus vent was plumbed across location to the produced water tanks. The 9 5/8 x 13 3/8 and 13 3/8 x 20 annulus vents were open and 0% combustible gas was detected at time of inspection. No violations were noted at time of inspection.
2833652 Primary Facility 2019-01-28 Routine/Complete Inspection No Violations Noted On January 28, 2019, Department representative Brad Kline conducted a routine site inspection at EXCO Resources, LLC. Bower Pad 1H. Site inspection log was onsite for review. No E&S issues were observed during the time of inspection. The site is stable and well vegetated meeting the 70% uniform, perennial, vegetative cover.

There are a total of 5 producing wells located on this well pad. All wells are tagged with API/well permit numbers. Well cellars are filled in with gravel. There are 5 GPU’s and 4 steel vertical production fluids tanks onsite. Production fluid tanks were stationed in secondary containment.

No violations noted. The Department recommends submitting a Notice of Termination and a Well Site Restoration Report when the criteria is met.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1997759 618485 08/22/2011 2011-08-22 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days Administrative bubbling 13 3/8 x 9 5/8 casing annulus

For data sources see[7]

References