If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20717 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.283697,"lon":-76.589689,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Penn Township | |
Operator Name: EXCO RESOURCES PA LLC | |
Well Pad ID: 148239 | |
Farm/Lease Name: DOEBLER UNIT 2H | |
License Status: Active | |
Spud Date: 2011-11-09 | |
Permit Date: 2011-10-17 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.283697 | |
Longitude: -76.589689 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-08-07 | 2013-08-28 | 7297 | 3,860,010.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Water | Operator | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 84.7562 | 0 |
FR-66 | Halliburton | Friction Reducer | Hydrotreated light petroleum distaillate | 64742-47-8 | 30 | 0.02749 | 0 | |
Scalechek LP-65 Scale Inhibitor | Halliburton | Scale Inhabitor | Ammonium chloride | 12125-02-9 | 10 | 0.00195 | 0 | |
LCA-1 | Halliburton | Solvent | Paraffinic solvent | Proprietary | 100 | 0.00214 | 0 | |
SAND-PREMIUM WHITE | Halliburton | Proppant | Crystalline Silica, quartz | 14808-60-7 | 100 | 12.3767 | 0 | |
SSA-2 | Halliburton | Proppant | Crystalline Silica, quartz | 14808-60-7 | 100 | 2.10025 | 0 | |
BE-9 | Halliburton | Biocide | Tributyl tetradecyl phosphonium chloride | 81741-28-8 | 30 | 0.02749 | 0 | |
FE ACID-<10% HCL | Halliburton | Acid | Hydrochloric acid | 7647-01-0 | 10 | 0.0633 | 0 | |
HAI-OS ACID INHIBITOR | Halliburton | Corrosion Inhibitor | Methanol | 67-56-1 | 60 | 0.00061 | 0 | |
Propargyl alcohol | 107-19-7 | 10 | 0.0001 | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | EXCO RESOURCES PA LLC | 1,016,984.00 | 360 | 0.00 | 0 | 0.00 | 0 |
2015 | EXCO RESOURCES PA LLC | 715,080.00 | 349 | 0.00 | 0 | 0.00 | 0 |
2016 | EXCO RESOURCES PA LLC | 472,654.00 | 277 | 0.00 | 0 | 0.00 | 0 |
2017 | EXCO RESOURCES PA LLC | 510,103.00 | 337 | 0.00 | 0 | 0.00 | 0 |
2018 | EXCO RESOURCES PA LLC | 429,598.00 | 334 | 0.00 | 0 | 0.00 | 0 |
2019 | EXCO RESOURCES PA LLC | 105,375.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | EXCO RESOURCES PA LLC | Drill Cuttings (in Tons) | 623.44 Tons | LANDFILL | 301358 |
2013 | EXCO RESOURCES PA LLC | Fracing Fluid Waste (in Barrels) | 5,800.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid (in Barrels) | 1,459.10 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid (in Barrels) | 54.76 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid (in Barrels) | 1,095.68 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC009 |
2013 | EXCO RESOURCES PA LLC | Fracing Fluid Waste (in Barrels) | 350.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC024 |
2013 | EXCO RESOURCES PA LLC | Fracturing Fluid Waste (in Tons) | 29.50 Tons | LANDFILL | 301358 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid (in Barrels) | 689.26 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC024 |
2013 | EXCO RESOURCES PA LLC | Fracing Fluid Waste (in Barrels) | 534.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EXCO RESOURCES PA LLC | Produced Fluid (in Barrels) | 219.10 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC024 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid (in Barrels) | 439.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid (in Barrels) | 220.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2015 | EXCO RESOURCES PA LLC | Produced Fluid (in Barrels) | 110.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2016 | EXCO RESOURCES PA LLC | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2016 | EXCO RESOURCES PA LLC | Produced Fluid (in Barrels) RWC 802 | 165.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2017 | EXCO RESOURCES PA LLC | Produced Fluid (in Barrels) RWC 802 | 155.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2018 | EXCO RESOURCES PA LLC | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2018 | EXCO RESOURCES PA LLC | Produced Fluid (in Barrels) RWC 802 | 122.90 Bbl | REUSE (AT WELL PAD) | |
2019 | EXCO RESOURCES PA LLC | Produced Fluid (in Barrels) RWC 802 | 107.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2012633 | Primary Facility | 2011-10-20 | Drilling/Alteration | No Violations Noted | |
2034062 | Primary Facility | 2012-01-12 | Drilling/Alteration | No Violations Noted | |
2062926 | Primary Facility | 2012-04-25 | Routine/Complete Inspection | No Violations Noted | |
2067471 | Primary Facility | 2012-05-11 | Routine/Complete Inspection | No Violations Noted | |
2077297 | Primary Facility | 2012-06-14 | Follow-up Inspection | No Violations Noted | |
2092261 | Primary Facility | 2012-08-16 | Routine/Partial Inspection | No Violations Noted | |
2098767 | Primary Facility | 2012-09-11 | Routine/Partial Inspection | No Violations Noted | |
2098794 | Primary Facility | 2012-09-05 | Routine/Complete Inspection | No Violations Noted | |
2117182 | Primary Facility | 2012-11-20 | Routine/Complete Inspection | No Violations Noted | |
2123226 | Primary Facility | 2012-12-06 | Routine/Complete Inspection | No Violations Noted | |
2125968 | Primary Facility | 2012-12-21 | Complaint Inspection | No Violations Noted | |
2151239 | Primary Facility | 2013-03-27 | Drilling/Alteration | No Violations Noted | |
2198891 | Primary Facility | 2013-08-26 | Routine/Complete Inspection | No Violations Noted | |
2575309 | Primary Facility | 2017-03-20 | Routine/Complete Inspection | No Violations Noted | I entered the site at 09:40, in response to a spill notification phone call I received from Bird Smith (EXCO) at 08:20 this morning. Mr. Smith reported that
approximately 56 barrels of produced water were released to containment from the bottom valve on the Doebler 3H (081-20718) produced water tank. The release was caused when the produced water froze in the valve and dislodged the gasket. At the time of the inspection, the Doebler 1-5H (081-20454, 081- 20717, 081-20718, 081-20719, 081-20720) wells were in production. Water was actively leaking from the bottom valve on the production tank for the Doebler 3H well but the vac-truck driver/operator was onsite vacuuming water from the containment. Snow was covering the ground around the containment and I found no evidence that any produced water had leaked out of the containment. Field conductivity of produced water in the containment was between 1650- 1995 umhos/cm at several locations. The conductivity of the produced water is significantly lower than expecte |
2800849 | Primary Facility | 2018-11-08 | Routine/Complete Inspection | No Violations Noted | Five wells staged for production phase. Five each water separators. No leaks detected from production equipment. No violations noted. |
2845618 | Primary Facility | 2019-02-27 | Routine/Complete Inspection | No Violations Noted | Five wells staged for production phase. Five each water separators. No leaks detected from production equipment. No violations noted. |
For data sources see[7]