X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-083-24412

Well Details

Well ID: 34-083-24412
Loading map...
Country: United States
State: Ohio
County: Knox
Municipality: Clay Township
Operator Name: MORAN WELL SERVICE INC.
Well Pad ID:
Farm/Lease Name: MORAN PHIL(SWIW #7)
License Status: Active Injection
License Date: 2009-10-16
Spud Date: 2008-10-03
Spud Drilling Contractor: BOWMAN DRILLING
Final Drill Date: 2008-10-06
Well Total Depth: 2588 ft
Configuration: Vertical
Latitude: 40.288751479
Longitude: -82.30614356

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-09-19 Proposed Formations:CLINTON, Issued Date:9/19/2008, Expired Date:9/19/2009 6:00:00 AM, Drilling unit acres:84.27, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-10-06
Completion Report Received 2008-12-04
Annulus Pressure Monitoring Approved 2009-10-16
APP 2009-10-16 Proposed Formations:NEWBURG, Issued Date:10/16/2009, Expired Date:10/16/2010 6:00:00 AM, Drilling unit acres:84.27, Proposed Well Type:SWD, Proposed Well Class:SWIW
Plugged Back 2009-10-21
Construction Permit Expires 2010-10-16
Last Compliance Report 2012-04-14
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-07-21 2300 2430 40

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 MORAN WELL SERVICE INC. 300 20 100
2009 MORAN WELL SERVICE INC. 0 0 0
2012 LBJ DRILLING CO INC 0 0 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 MORAN WELL SERVICE INC. Brine 1000 100
2009 MORAN WELL SERVICE INC. Brine 0 0
2012 LBJ DRILLING CO INC Brine 4726 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0025956674 2015-01-14 Brine Hauler No Violations Inspect Berry Well Service truck UIC # 354 brine hauler; no issues. Inspect Dow Cameraon truck UIC #343 brine hauler; no issues.
0120259573 2013-06-26 Preliminary Restoration No Violations Well is and injection well no violations during inspection.
0133148109 2015-03-23 Salt Water Injection Well No Violations Inspect storage and unloading facility. No activity and pump was not in operation during inspection.
0136584635 2012-04-11 Salt Water Injection Well No Violations I accompanied Brent Bear during this inspection. Phil Moran was pulling tubing and replacing it with new tubing and packer.
0190994166 2015-10-08 Salt Water Injection Well No Violations Inspect well for integrity and pressure. The well is shut in. No activity to service well has occurred.
0205085104 2015-05-27 Salt Water Injection Well Violations Noted Contacted by operator to report the mechanical integrity of the packer and tubing has failed. The well has been shut in. Service on the well will begin within the next few days.
0224669197 2013-10-24 Salt Water Injection Well No Violations Inspect well for integrity and pressure.
0255656973 2015-03-16 Salt Water Injection Well No Violations Inspect unloading and storage facility. Pump in operation. Line pressure at pump house was 520 psi.
0265171698 2009-11-05 Salt Water Injection Well No Violations I witnessed the construction of this dike facility. Three 300 barrel tanks are being placed inside of the dike along with the pump house.
0267628707 2018-08-30 Salt Water Injection Well No Violations Inspect well. The well is shut in and incapable of injecting fluids. Compliance notice was issued May 27, 2015.
0273875286 2010-11-10 Salt Water Injection Well No Violations The inspection showed that there was 85psi on the injection and 0psi on the annular space. There was proper identification posted. There were no violations noted this date.
0285994434 2012-08-15 Salt Water Injection Well No Violations I inspected this well today at approximately 11:00 am. There were no trucks unloading during inspection and the pump was running. ID was posted at the tank battery and at the well. No violations observed.
0294523782 2012-02-07 Salt Water Injection Well No Violations Returned to the well location today and met with Mr. Phil Moran, well owner, to check the status of this well. The pump was running at time of inspection. 170 psi was observed on the injection side of well and now 21 psi on annulus. Mr. Moran agreed to closely monitor well status.
0298345922 2012-12-20 Salt Water Injection Well No Violations I inspected this injection well and facility today accompanied by UIC Inspector Tom Benko. No trucks unloading during visit. The pump was not running. No violations were observed.
0312866163 2014-04-22 Brine Hauler No Violations LBJ Drilling Co. UIC 103 unload at facility. Truck identification ok.
0389071904 2012-04-12 Salt Water Injection Well No Violations I accompanied Brent Bear during this inspection. Phil Moran was running new tubing and packer in the well.
0390535948 2010-07-01 Drill / Deepen / Reopen No Violations I witnessed drilling operations today. B&J Drilling are drilling at a depth of 518 feet. All fluids are being contained within a properly lined pit. There are no violations noted this date.
0392443168 2015-03-02 Brine Hauler No Violations Inspect storage facility, pump shut down belts require replacing, pressure at pump house 480 psi. Dow Cameron Truck DC27 Trailer TK 8, UIC 343 deliver filter water from Dow Cameron Storage 060-2014-7. Measure specific gravity at 1.050 units.
0423129706 2012-04-12 Salt Water Injection Well No Violations I witnessed the construction and testing activity performed on this saltwater injection well today. Cemenco pumped packer inhibitor through 2 7/8 tubing and circulated to the surface. The well was shut-in and 625 psi was placed on the annulus. The pressure was monitored for the required 15 minutes with an allowance of 5% decline. After 15 minutes, my gauge showed 622 psi with only 3 psi loss. The well passed the required test.
0467913146 2015-03-05 Salt Water Injection Well No Violations Inspect Storage and unloading area. No activity during inspection.
0540945870 2014-07-08 Salt Water Injection Well No Violations Inspect well for integrity and pressure.
0561691177 2015-02-09 Brine Hauler No Violations Dow Cameron Truck DC28 UIC #343 delivered a load of filter water from the Dow Cameron Storage Facility UIC #60-2014-7. The Specific Gravity of the load of water was measured at 1.020 units.
0566460658 2016-04-13 Salt Water Injection Well No Violations Inspect well. Compliance order follow up. Well is shut in. No activity to pull packer and tubing. Location has standing water and is wet.
0673572392 2014-06-16 Brine Hauler No Violations Inspected Three Dow Cameraon Brine tanker trucks. Collected brine water sample TSB056 for chemical analysis from truck DC26 trailer TK3. Inspected truck DC25 trailer TK7 and truck DC14 trailer TK5. Markings and log were present.
0711306269 2016-07-21 Salt Water Injection Well No Violations Inspect well. This well has not been serviced and is shut in.
0775379107 2012-04-11 Salt Water Injection Well No Violations An inspection revealed service rig on location to pull 2 3/8 tubing and packer from wellbore, due to pressure equalization. During the retrieval, the top of packer came loose and fell down the hole. Mr. Phil Moran ran his tools in the hole and verified packer was on bottom of well. Witnessed the installation of used 2 7/8 tubing with new Parmaco Packer into the wellbore with Jeff Fry and Brandon Mitchell. Packer inhibitor and pressure test will be conducted tomorrow.
0810794191 2015-06-13 Salt Water Injection Well No Violations Inspect well for integrity and pressure. Well is shut in. Integrity of packer and tubing has failed. Operator is scheduled to work on well.
0885350827 2009-11-06 Salt Water Injection Well No Violations I witnessed the construction of the dike, the setting of tanks, and pump house.
0924745369 2013-01-29 Salt Water Injection Well No Violations I inspected the tank battery facility at this salt water injection well location today. There were no trucks during inspection. The pump was not running. No violations.
0933679790 2012-01-31 Salt Water Injection Well No Violations I accompanied Jeff Fry and Will Ziegler during this inspection.
0979493811 2014-07-08 Brine Hauler No Violations Inspect Dow Cameron Oil and Gas brine hauling truck UIC 343. Tractor DC28 with Trailer TK4. Log and truck ok.
1027772381 2014-01-09 Salt Water Injection Well No Violations Inspect well for integrity and pressure. Pump in operation during inspection.
1034928003 2015-06-23 Salt Water Injection Well No Violations Inspect well. Well is shut in for work over.
1043301093 2012-01-31 Salt Water Injection Well No Violations Site inspection with Jeff Fry and Will Ziegler, injection pump is leaking into the dike, operator will be advised to repair,
1055474052 2015-02-23 Brine Hauler No Violations Inspect storage and unloading facility. Operator thawed out frozen lines over weekend, subsequently the lines re-froze due to extreme cold. Dow Cameron Truck DC27 Trailer TK8, UIC 343, collect sample to measure specific gravity at 1.070 units. Dow Cameron Truck DC 28 UIC 343, collect water sample to measure specific gravity at 1.075 units.
1071446012 2018-05-03 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the 2017 Salt Water Injection Well Annual Report (Form 204) that was due to the Division by April 15, 2018. Please submit the requested report by June 4, 2018. Reports received 6/4/2018.
1122011437 2013-05-13 Salt Water Injection Well No Violations Inspect tank facility. No truck activity. Operator indicated it has been slow the last few weeks.
1135124045 2009-11-12 Salt Water Injection Well No Violations I inspected the construction of the tank battery and dike location today. The pump house building has been built and located inside the dike along with three 300 barrel tanks. A concrete unloading pad has been constructed with a curb around the outside. There is a drain the pad that leads to the an underground tank. The lead line to the well has been placed on top of the ground but has not yet been pressure tested.
1159557783 2019-02-11 Salt Water Injection Well Violations Noted The Division has not received the 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019.
1182917576 2015-02-09 Salt Water Injection Well No Violations Inspect storage location. The pump is in operation. The injection well was not inspected.
1197986938 2014-04-22 Salt Water Injection Well No Violations Inspect well. Well in production. Pump running during inspection.
1223143511 2008-10-04 Drill / Deepen / Reopen No Violations Witnessed cementing of surface casing. Good returns.
1256225688 2009-10-21 Plug / Plug Back No Violations I witnessed the bottom hole plug today. There was 25 sacks of cement used to plug the Clinton by the bulhead method for 300 feet of fill up. The well is being plugged back to be used as an underground injection well. The pressure test is set up for 10-23-09. I also witnessed the construction of the dike area and the installation of the 30 mil liner and sand. Construction will continue tomorrow and into next week.
1256742774 2009-10-22 Salt Water Injection Well No Violations Phil Moran is completing the construction of the dike. Four inches of sand was placed underneath and on top of a 30 mil liner. Around the dike walls an additional liner was used. This second liner was placed on top of the sand and the 30 mil liner. Gravel screenings was then placed on top of this second liner. The dike measures 40 feet by 60 feet with approximately 40 inch side walls. It will contain three 300 barrel tanks and the pump.
1260808461 2009-12-14 Salt Water Injection Well No Violations I inspected the tank battery / pump house location of this injection well today. Phil Moran was not on location. The line between the tanks and the well need to be pressure tested. The pump was not running and there was zero pressure on the line. 882 barrels have been pumped. There were no violations noted this date.
1265347316 2014-05-30 Brine Hauler No Violations This date received a phone call from John Niceswanger saying all of Dow Camerons fleet has been equipped or stenciled with their phone number .
1276858044 2012-03-30 Salt Water Injection Well Violations Noted An inspection of this saltwater injection well revealed pressure equalization. Vacuum was observed on both the injection and annular sides of the well. Note: The injection pump was not running at time of inspection. At the conclusion of inspection, I notified the well owner, Mr. Phil Moran, of this deficiency by telephone. Mr. Moran agreed to resolve, as this well had exhibited the same conditions back in February. (Note: While pumping since February, pressure would be observed on the injection side and Mr. Moran would add fluid to annular space resulting in no vacuum.) Absorbent pads have been placed around the pump inside the pump house.
1285448688 2016-01-21 Salt Water Injection Well No Violations Inspect well for integrity and pressure. The well is currently shut in.
1293125901 2010-12-23 Administrative Inspection No Violations Talked to well operator Phil Moran this date. ID is posted.
1322591972 2011-11-29 Salt Water Injection Well No Violations An inspection revealed no violations at this time. The injection pump was running at time of the inspection. Flowmeter not installed at this time. Note: Rainfall event today.
1345293194 2017-01-26 Salt Water Injection Well No Violations Inspect well. This well has not been serviced and is shut in. The wellhead pressures were not collected due to previous compliance notification.
1353301723 2017-11-03 Salt Water Injection Well No Violations Inspect well. The well is shut in and incapable of injecting fluids. Compliance notice was issued May 27, 2015.
1362597490 2013-02-25 Salt Water Injection Well No Violations Inspect Surface facility. Collect brine sample TSB021 from tanks. Water sample is primarily flow back water delivered by Dow Cameron from the Gulph Port Energy, Lyons #1-27H, 3406721088. Measure tank storage dike area; 45 ft by 69 ft by 3.25 ft.; Three 300 bbl tanks.
1368474243 2018-10-16 Salt Water Injection Well No Violations Inspect well. The well is shut in and incapable of injecting fluids. Compliance notice was issued May 27, 2015.
1369257729 2014-11-21 Salt Water Injection Well No Violations Inspect facility with Jennifer Gingras and Ken Brown. No activity during inspection.
1373965125 2014-08-27 Salt Water Injection Well No Violations Inspect facility. Pump in operation during inspection. Collect Brine sample TSB064 for chemical analysis.
1381313979 2009-10-27 Salt Water Injection Well No Violations Cemenco used there pump truck to pressure up on this well today in order to get the formation to brake and open up. The well was taking approximately 2 barrels a minute at 750 psi. Phil Moran, the well owner would like to see it do better than that and will treat the well with more acid. Producers came this afternoon and treated the well with 1200 gallons of acid and also pumped pressure on the well. The well then took about 6 barrels a minute with 750 psi.
1387216027 2010-12-22 Salt Water Injection Well No Violations Well not running. Met owner Phil Moran. Questions on forms. Did not go to well head. Facility appears ok. Needs ID.
1393427423 2014-02-24 Salt Water Injection Well No Violations Inspect well and tank battery. Pump off during inspection. Collect brine water sample for chemical analysis TSB047.
1397144809 2014-04-10 Brine Hauler No Violations Inspect Brine Truck Wilsons Water Hauling UIC 25-309.
1402315543 2014-05-29 Brine Hauler Violations Noted Stopped at injection well and assisted Inspector Benko, and operator Phil Moran to pressure test injection line from pump house to both injection wells. This permit and permit 4603. While I was at the pump house a red semi tanker belonging to Dow Cameron arrived to unload. UIC 343, driver D. Grubbs. Truck was a red Peterbuilt license PHJ382, with a red trailer license TQA7107. At 10:15am I checked his hauler log. This was his second trip this date from frac tanks at their yard, storage Permit 2014-07 . Both times he had a load of 130 Bbl.. Log was correct but truck failed to have the Dow Camerons phone number displayed per 1509.223. I informed the driver of violation. He then called their shop and had me talk to John Niceswanger. I informed John of requirements of 1509.223 and he informed me they would correct with decals and notify me when done.
1408120422 2014-08-07 Salt Water Injection Well No Violations Inspect facility. There were not any trucks unloading during inspection. Recipes for four trucks were at the facility.
1410261665 2014-09-08 Brine Hauler No Violations Inspect brine hauler at unloading pad. Sheeler Dozer Service UIC 25366; Log and truck are current. Collected Brine sample Number TSB065 from truck for chemical analytical analysis. The water was from the Sands #1 in Licking county API # 34089234690000.
1424182378 2015-02-12 Brine Hauler No Violations Inspect storage and unloading area. Pump in operation, pressure at pump house is 620 psi. Dow Cameron truck DC 28 UIC #25-343 deliver 130 bbl of filter water from Dow Cameron storage UIC 60-2014-7. Collect water sample, and measure Specific Gravity at 1.055 units.
1424875185 2015-02-17 Brine Hauler No Violations Inspect unloading facility. Lines are frozen due to extreme cold. Bremer Steam Service deliver load of brine water. Measure specific gravity at 1.230 units equates to 10.25 lb./gallon water.
1426085181 2015-03-04 Salt Water Injection Well No Violations Inspect Storage and unloading area. No activity during inspection.
1433940579 2015-06-10 Salt Water Injection Well No Violations Corrective action for exceeding approved injection pressure released as a result of the issuance of an Order by the Chief Order Number 2015-295; Modification of Permit to increase the Maximum Allowable Injection Pressure, dated June 8, 2015.
1490905748 2009-10-23 Salt Water Injection Well No Violations A pressure test on the bottom hole plug was performed today. A solvent truck was used to pressure up on the well. At 9:25 am the test began with 715 psi on the well. At 9:40 am there was 705 psi on the well. The well passed the pressure test as there was less than 5% loss during the 15 minute test.
1495067179 2014-10-27 Salt Water Injection Well No Violations Inspect well for integrity and pressure. The well is shut in.
1497619997 2017-06-16 Salt Water Injection Well No Violations Follow-up for compliance notice issued 5/27/2015. Inspect well. The well is shut in and incapable of injecting fluids.
1502190819 2017-08-01 Salt Water Injection Well No Violations Inspect well. The well is shut in and incapable of injecting fluids. Compliance notice was issued May 27, 2015.
1521206121 2018-03-13 Salt Water Injection Well No Violations Inspect well. The well is shut in and incapable of injecting fluids. Compliance notice was issued May 27, 2015.
1526384958 2018-05-14 Salt Water Injection Well No Violations Inspect well. The well is shut in and incapable of injecting fluids. Compliance notice was issued May 27, 2015.
1568162415 2011-10-03 Salt Water Injection Well No Violations Meet Phil moran at site and went over operation of well and site.
1582093509 2014-04-10 Salt Water Injection Well No Violations Inspect well for integrity and pressure. The annulus valve is open.
1613746013 2015-02-02 Salt Water Injection Well No Violations Inspect well and storage facility. Operator collected a water sample from a Dow Cameron Truck the previous day to test for the specific gravity. The specific gravity of the water sample was tested with a hydrometer and determined to be 1.04 units. During the inspection the Dow Cameron Truck DC-28 with trailer TK-4, UIC #343, delivered 130 bbl of water from the Dow Cameron storage facility. A sample of water was collected and the specific gravity of the water was measured with the hydrometer and determined to be 1.07 units.
1679013550 2014-08-21 Brine Hauler No Violations Inspect Dow Cameron truck UIC#343; Tractor DC-28; Trailer TK-4 at well head.
1688040990 2015-02-26 Salt Water Injection Well No Violations Inspect well and facility. No activity during inspection.
1692194018 2015-02-19 Salt Water Injection Well No Violations Inspect storage and unloading facility. No activity at facility due to discharge lines being frozen.
1710360862 2012-06-27 Salt Water Injection Well No Violations Today I inspected the tank battery for the injection well accompanied by Jeff Fry. During inspection a brine truck with Diversified Resources was unloading a tank of water. UIC number was displayed and visible. The UIC number was 25-424. No violations during inspection.
1769634894 2014-09-08 Brine Hauler No Violations Inspect brine truck at unloading pad. Dow Cameron UIC# 25343; Tractor DC28 and Trailer TK4. The Log book and truck are current. The Moran well service pump filters have been plugged up prematurely and casing the pump to shut down. The Dow Cameron Tuck unloaded 130 bbl of sludge type brine water to be disposed at a different facility.
1786442845 2013-09-05 Salt Water Injection Well No Violations Did pressure checks with Thomas Benko.
1792712278 2016-10-06 Salt Water Injection Well No Violations Inspect well. This well has not been serviced and is shut in. The wellhead pressures were not collected due to previous compliance notification.
1810808874 2013-09-05 Salt Water Injection Well No Violations Inspect well for integrity and pressure.
1811567986 2017-05-15 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on April 15th for 2016, despite a letter that was sent April 28, 2017 with a deadline of May 12, 2017 to submit the reports requested. please submit the requested Forms to the Division by 5/26/2017. REPORTS RECEIVED 6/6/2017
1888934474 2009-09-30 Salt Water Injection Well No Violations Jeff Fry and I inspected the well location at the request of Tom Tomastik. We met with the landowner and well owner Phil Moran. He explained his intentions about converting his Clinton well into a salt water injection well. We discussed the area to be used for the unloading pad, storage tanks, dike construction, and the plug back procedures for this operation. Also, we took GPS coordinates for the nearest water well, which is on Phil Morans property.
1899618550 2015-01-23 Salt Water Injection Well Violations Noted Inspect well for integrity and pressure. Injection pump in operation during inspection. Operator pumping lighter weight water during inspection.
1907153924 2013-06-20 Brine Hauler No Violations Inspect water truck Berry Well service Truck UIC 25-354 truck #143. Collect water sample from the truck for chemical analysis sample TSB029.
1909451003 2015-02-24 Brine Hauler No Violations Inspect storage and pump facility. Inspect Dow Cameron Truck DC27 trailer TK8 UIC 343 deliver filter water from Dow Cameron storage facility 060-2014-7. Collect Brine sample TSB071 from truck during unloading for chemical analysis; pH about 7, acidified sample pH about 1, the specific gravity measured at 1.050 units.
1942572568 2009-12-30 Salt Water Injection Well No Violations Jeff Fry and I inspected this well location today and performed a pressure test on the pipeline between the tank battery and the injection well. The pressure test passed. The test began with 620 psi at 9:32am and ended at 9:47 with 620 psi. Phil Moran was also on location. Phil still needs to post proper identification and the construction of this injection well facility will be complete.
1978882999 2011-09-26 Salt Water Injection Well No Violations An inspection revealed no violations.
2035819234 2009-10-26 Salt Water Injection Well No Violations Jet Wireline Services, Inc. perforated this well today. The well was loaded with acid and then salt water before being perforated. There were a total of 41 shots. They were 2 and 1/8 bi-wire shots. The perforation was from 2365 to 2405.
2063467839 2015-08-10 Salt Water Injection Well No Violations Inspect well for integrity and pressure. Well is shut in for repairs.
2126940036 2014-08-21 Salt Water Injection Well No Violations Inspect well for pressure and integrity. The pump was in operation at the storage facility. The well was shut in during inspection.
2130956941 2012-02-06 Salt Water Injection Well No Violations An inspection revealed that well contained vacuum on both injection and annulus sides of well. Note: Pump not running at time of inspection. The annulus valve was opened for approx 10 seconds with constant vacuum. After checking the injection side of well and observing vacuum, the annulus valve was again opened and verified presence of vacuum. At 9:37 am, I left Mr. Phil Moran a voicemail message. Mr. Moran would check well later this evening while pump was running and observed vacuum on annulus. However, states it eventually blew down. Further stating 200 psi on injection and filled fill annulus with approx 15 gal of water. Agreed to meet at well location tomorrow for further review.
2135920832 2010-09-23 Salt Water Injection Well No Violations Well not operating. Needs ID posted at facility and wellhead. Talked to County Inspector Will Ziegler. He contacted well operator Phil Moran this am on ID and pressure monitoring.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0205085104 US-OH-120891 2015-07-29 Violation of injection tubing/fitting requirements
0205085104 US-OH-120892 2015-07-29 Failure to pass required test
1071446012 US-OH-101485 2018-08-03 Failure to file salt water injection annual report
1159557783 US-OH-104228 2019-04-08 Failure to report disposal fees
1276858044 US-OH-107687 2012-04-24 Failure to monitor pressures/volumes
1276858044 US-OH-107688 2012-04-24 Mechanical failure/contamination
1402315543 US-OH-111907 2014-06-12 Failure to properly identify brine hauling truck
1811567986 US-OH-118092 2017-06-29 9-3-04B Failure to file salt water injection annual report
1899618550 US-OH-119090 2015-06-18 Exceeding maximum allowable injection pressure

For data sources see[9]

References