34-085-21060

Well Details

Well ID: 34-085-21060
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Mentor
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: MERCANTILE
License Status: Producing
License Date: 2003-06-27
Spud Date: 2003-11-07
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2003-11-11
Well Total Depth: 3260 ft
Configuration: Vertical
Latitude: 41.702157628
Longitude: -81.29377015

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2003-06-27 Proposed Formations:CLINTON, Issued Date:6/27/2003, Expired Date:6/26/2004 6:00:00 AM, Drilling unit acres:87, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2003-11-07 RBDMS Rec
Completed 2003-11-11 RBDMS Rec
Reached Total Depth 2003-11-11 RBDMS Rec
Construction Permit Expires 2004-06-26 RBDMS Rec
Completion Report Received 2004-09-02 RBDMS Rec
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-10-21 2995 3007 13

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 400 Bbl 90000 500 GALLONS HCL ACID & 560M SCF NITROGEN

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 GREAT PLAINS EXPLORATION LLC 2878 0 305
2005 GREAT PLAINS EXPLORATION LLC 3418 98 365
2006 GREAT PLAINS EXPLORATION LLC 3513 0 365
2007 GREAT PLAINS EXPLORATION LLC 3064 0 365
2008 GREAT PLAINS EXPLORATION LLC 2138 0 365
2009 GREAT PLAINS EXPLORATION LLC 2857 0 365
2010 GREAT PLAINS EXPLORATION LLC 3123 0 365
2011 GREAT PLAINS EXPLORATION LLC 2300 0 365
2012 GREAT PLAINS EXPLORATION LLC 2209 13 366
2013 GREAT PLAINS EXPLORATION LLC 878 15 365
2014 GREAT PLAINS EXPLORATION LLC 1458 0 365
2015 GREAT PLAINS EXPLORATION LLC 381 0 365
2016 ROCKEFELLER OIL COMPANY LLC 790 0 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 GREAT PLAINS EXPLORATION LLC Brine 0 305
2005 GREAT PLAINS EXPLORATION LLC Brine 80 365
2006 GREAT PLAINS EXPLORATION LLC Brine 0 365
2007 GREAT PLAINS EXPLORATION LLC Brine 400 365
2008 GREAT PLAINS EXPLORATION LLC Brine 480 365
2009 GREAT PLAINS EXPLORATION LLC Brine 320 365
2010 GREAT PLAINS EXPLORATION LLC Brine 320 365
2011 GREAT PLAINS EXPLORATION LLC Brine 240 365
2012 GREAT PLAINS EXPLORATION LLC Brine 240 366
2013 GREAT PLAINS EXPLORATION LLC Brine 80 365
2014 GREAT PLAINS EXPLORATION LLC Brine 310 365
2015 GREAT PLAINS EXPLORATION LLC Brine 78 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0000086975 2016-02-18 UrbanProduction Wells Violations Noted I inspected this producing well as part of routine inspection activity. At the time of my inspection, I observed the following elements: a wellhead with mechanical plunger lift and tank battery consisting of one 100-barrel FRP and one 100-barrel steel stooge tank, with mechanical separator. The battery and wellhead were in in separate chain-link enclosures. Fittings and connections are free from leakage. The dedicated access road is in good condition. The enclosure gates and load-line valves are not locked and should be secured with locks. I measured the distance from the tank battery separator to the wellhead to be 10 feet. The distance from the mechanical separator to the production tank was 8 feet. OAC 1501:9-9-05(A) requires a minimum distance of 50 feet between the wellhead and the battery and 10 feet between the separator and the production tank. The owner must remedy the following by 03/25/2016: secure the load-line valves and enclosure gates with locks. Reconfigure the tank battery to meet the required separation distance. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
0571706744 2017-09-06 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: the load-lines were not secured with locks and the tank spacing within the battery was not compliant . In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. At the time of this inspection, the aforementioned deficiencies had not been remedied. The owner has made repeated pledges to address the issues, but with no demonstrable progress.
1462364941 2019-04-02 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice #86975, regarding production equipment spacing between the well and tank battery equipment and installation of locks on the tank valves and load lines as well as the fencing around the tank battery. At the time of my inspection, the enclosure gates and load-line valves are not locked and should be secured with locks. The distance from the tank battery separator to the wellhead has not been changed, nor has the distance from the mechanical separator to the production tank been reconfigured.

Rockefeller Oil Company, LLC needs to: 1) Reconfigure the tank battery to meet the required separation distance per: OAC 1501:9-9-05(A). 2) Secure the load-line valves and enclosure gates with locks.

1555145257 2017-04-19 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previously-issued compliance notice for the following: missing locks at the load-line valves and violation of the tank spacing requirements. At the time of this inspection, I observed the following: The load-line valves were not secured with locks and the production tank remained less than 10 feet from the mechanical separator unit. In addition, the ID signage has not been upgraded to reflect the change in ownership and is missing information required under OAC 1501:9-9-05(E)(1). I have attempted to contact the owner regarding the need for upgrade to the ID signage and, at the time of the filing of the report, have not received a response.
1781338150 2015-01-13 UrbanProduction Wells No Violations The fiber-reinforced production tank has been replaced with a steel tank and moved to address the spacing compliance problem. The unit is producing with no problems at the time of this inpsection.
1897335607 2017-12-12 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: The load-lines were no locked and secure, and the tank spacing was not in compliance. At the time of this inspection, I observed the following: the noted deficiencies remained. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance.
1985673941 2013-09-10 UrbanPreliminary Restoration Violations Noted The producing unit consists of a wellhead with mechanical plunger lift system and aboveground storage tank battery. The battery, separator, and wellhead are in separate chain-link enclosures. The battery is comprised of 1 100-barrel fiber-reinforced plastic (FRP) production tank, 1 100-barrel steel brine tank, and separator unit. The spacing between the production tank and the separator is less than 10 feet and is not in compliances with the required 10 feet. The spacing between the battery tanks are less than three feet and are not in compliance. There is adequate secondary containment. Locks and signage are present. The locked gated entry to the access road also requires a sign. The corrections should be made within 90 days.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0000086975 US-OH-129897 2016-04-27 LOCKS
0000086975 US-OH-129898 2016-04-27 Violation of separator spacing requirements
1985673941 US-OH-120100 2015-02-05 ID (a-i)
1985673941 US-OH-120101 2015-02-05 TANKS (a-I)

For data sources see[9]

References