If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-21251 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.62819616,"lon":-81.35766668,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Kirtland | |
Operator Name: DAVID OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: HORSBURGH | |
License Status: Producing | |
License Date: 2007-12-11 | |
Spud Date: 2008-01-16 | |
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC | |
Final Drill Date: 2008-01-23 | |
Well Total Depth: 3270 ft | |
Configuration: Vertical | |
Latitude: 41.628196160 | |
Longitude: -81.35766668 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-10-29 | Proposed Formations:CLINTON, Issued Date:10/29/2007, Expired Date:10/28/2008 6:00:00 AM, Drilling unit acres:20.22, Proposed Well Type:OG, Proposed Well Class:POOL |
APP | 2007-12-11 | Proposed Formations:CLINTON, Issued Date:12/11/2007, Expired Date:12/10/2008 6:00:00 AM, Drilling unit acres:20.22, Proposed Well Type:OG, Proposed Well Class:POOL |
Correction to Well | 2007-12-21 | CORRECTION TO FOOTAGE, SHOULD BE "314'SL & 1113'EL OF LOT 18, TRACT 1". |
Correction to Well | 2007-12-28 | CORRECTION TO FOOTAGE, SHOULD BE "314'SL & 1113'EL OF LOT 18, TRACT 1". |
Reached Total Depth | 2008-01-23 | |
Completion Report Received | 2008-03-04 | |
Construction Permit Expires | 2008-12-10 | |
Change of Owner | 2016-12-14 | Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-06-30 | 3086 | 3099 | 20 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 19664 Gal | 100000 | FRAC ALSO INVOLVED 584 MSCF OF N2 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | JOHN D OIL & GAS COMPANY | 11492 | 318 | 278 |
2009 | JOHN D OIL & GAS COMPANY | 22224 | 511 | 365 |
2010 | JOHN D OIL & GAS COMPANY | 10246 | 317 | 365 |
2011 | JOHN D OIL & GAS COMPANY | 6603 | 166 | 365 |
2012 | JOHN D OIL & GAS COMPANY | 3322 | 97 | 366 |
2013 | JOHN D OIL & GAS COMPANY | 3193 | 62 | 365 |
2014 | JOHN D OIL & GAS COMPANY | 3313 | 52 | 365 |
2015 | JOHN D OIL & GAS COMPANY | 3504 | 23 | 365 |
2016 | DAVID OIL COMPANY LLC | 478 | 0 | 61 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | JOHN D OIL & GAS COMPANY | Brine | 320 | 278 |
2009 | JOHN D OIL & GAS COMPANY | Brine | 800 | 365 |
2010 | JOHN D OIL & GAS COMPANY | Brine | 560 | 365 |
2011 | JOHN D OIL & GAS COMPANY | Brine | 320 | 365 |
2012 | JOHN D OIL & GAS COMPANY | Brine | 80 | 366 |
2013 | JOHN D OIL & GAS COMPANY | Brine | 145 | 365 |
2014 | JOHN D OIL & GAS COMPANY | Brine | 160 | 365 |
2015 | JOHN D OIL & GAS COMPANY | Brine | 60 | 365 |
2016 | JOHN D OIL & GAS COMPANY | Brine | 0 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0960896678 | 2009-09-17 | Preliminary Restoration | No Violations | Preliminary restoration was completed. |
1014986635 | 2008-01-16 | Drill / Deepen / Reopen | No Violations | aera graded silt fence installed ready for rig. |
1365223358 | 2008-01-17 | Drill / Deepen / Reopen | No Violations | surface |
1469340960 | 2017-09-08 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: the load-lines were no secured with locks. In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. At the time of this inspection, the aforementioned deficiencies had not been remedied. The owner has made repeated pledges to address the issues, but with no demonstrable progress. |
1700620403 | 2018-03-15 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: the load-lines were no secured with locks. In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. At the time of this inspection, the aforementioned deficiencies had not been remedied. The owner has made repeated pledges to address the issues, but with no demonstrable progress. |
1766662925 | 2016-02-18 | UrbanProduction Wells | Violations Noted | I inspected this producing well as part of routine inspection activity. At the time of my inspection, I observed the following elements: a wellhead with mechanical plunger lift and tank battery consisting of two100-barrel steel storage tanks, with mechanical separator. The battery and wellhead were in in separate board-on-board enclosures. Fittings and connections are free from leakage. The production tank did have a spark arrestor, a low-pressure relief valve, and carbon filter as required. Tanks lids were closed and sealed. The dedicated access road is in good condition. The enclosure gates were not locked and or secure. The load-line valves were not locked and must be secured with locks. The owner must remedy the following by 04/01/2016: secure the load-line valves and enclosure gates with locks. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection. |
1982952403 | 2012-10-26 | UrbanProduction Wells | No Violations | The unit consists of a 2-tank battery with mechanical separator in a 8-foot wooden fence. The spacing is in accordance with the rule, and the valves and mechanicals are in good repair. The dike is adequate. I did not observe any signs of leaking product or gas vapors. The wellhead is fitted with a mechanical lift and is enclosed in a 6-foot wooden fence. The well is producing. The lease road is in good repair. There is a locked gate at the head of the lease road |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1766662925 | US-OH-117574 | 2016-04-27 | LOCKS |
For data sources see[9]