If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-111-24831 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.666381772,"lon":-81.00901014,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Monroe | |
Municipality: Green Township | |
Operator Name: ECLIPSE RESOURCES I LP | |
Well Pad ID: US-OH-001486 | |
Farm/Lease Name: ROLLAND E | |
License Status: Plugged and Abandoned | |
License Date: 2018-03-16 | |
Spud Date: 2018-03-17 | |
Spud Drilling Contractor: | |
Final Drill Date: 2018-03-17 | |
Well Total Depth: 110 ft | |
Configuration: Horizontal | |
Latitude: 39.666381772 | |
Longitude: -81.00901014 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2018-03-16 | Proposed Formations:UTICA/POINT PLEASANT, Issued Date:3/16/2018, Expired Date:3/15/2020 12:00:00 PM, Drilling unit acres:138.147, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2018-03-17 | |
Plugged/Abandoned | 2018-07-19 | |
Record Last Modified | 2019-06-05 | |
Construction Permit Expires | 2020-03-15 |
For data sources see[2]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0244353062 | 2018-07-19 | Plug / Plug Back | No Violations | On site inspection to witness the well plugging process. The company has decided to move the surface location of the said well. Previously only 110 of 24 diameter surface casing was set along with a 60 mouse hole. Hanson Redi mix cement company out of New Martinsville West Virginia provided the 9 sack grout mix. With the calculated hole volume of 9 cubic yards. The cement weight was 18.5 pounds per gallon. The fluid level in the wells was pulled out with vacuum trucks prior to commencing the cement jobs. The well was grouted from surface and filled with Redi mix to 30 below grade level. A permanent marker was placed over the 24 conductor casing before backfilling the cellar. |
1591982070 | 2018-07-18 | Plug / Plug Back | No Violations | On site for a 16:00 pm call out to plug 2 wells on the pad with 24 conductor only set to 110. The cement trucks did not show up for the job. I was notified they would be plugging at 8:00 am the next morning. |
1668610190 | 2018-03-19 | Casing String Witnessed | No Violations | On the day inspection of my accompanied by ODNR Inspector Jeff Adams, I witnessed that Precision Rathole had drilled a 30 inch diameter hole to the depth of 120 feet and ran 122 feet of 24 inch diameter 94.62 pounds per foot conductor pipe with a 2 foot stick up. Stingray Pressure Pumping was onsite and pumped 2 barrels of fresh water, performed a 400 pounds per square inch pressure test, gained circulation with 7 barrels of fresh water and cemented pipe with 290 sacks Class A cement with 2% CaCl and .25 pound per sack of Celluseal weighing 15.6 pounds per gallon and a yield of 1.21 cubic foot per sack. Cement was weight was verified with pressurized mud scales and displaced to 110 feet with 57 barrels of fresh water with good cement returns of 13 barrels to surface. Mix water was tested revealing chlorides of 86 parts per million, pH 7 and 61 degrees. |
For data sources see[3]