Well Details

Well ID: 34-007-22868
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Morgan Township
Operator Name: CAMBRIAN HUNTER INC
Well Pad ID:
Farm/Lease Name: ABELL
License Status: Plugged and Abandoned
License Date: 2013-09-05
Spud Date: 1985-01-08
Spud Drilling Contractor: H.L.H. DRLG
Final Drill Date: 1985-01-14
Well Total Depth: 3489 ft
Configuration: Vertical
Latitude: 41.645339385
Longitude: -80.84987163

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-08-30 3698 CAMBRIAN HUNTER INC GeoDate 8/30/84
Oil and Gas 1984-08-30 Issued Date 8/30/84 Expired Date 1/30/85 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03489 Proposed Drill Depth 03489
Original Spud 1985-01-08
Completed 1985-01-14
Reached Total Depth 1985-01-14
Completion Report Received 1985-03-14
APP 2013-09-05 Proposed Formations:CLINTON, Issued Date:9/5/2013, Expired Date:9/5/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2014-09-29
Construction Permit Expires 2015-09-05
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3308 3342 14

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 40000 FRAC;H2O,SAND

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1176167724 2012-12-04 Production Wells Violations Noted Complainant Bill Abell [ landowner ] . My inspection of well found there is no tank battery for this well , further inspection of wellhead found tubing in production casing with valve which is shut-in . Well is disconnected from flowline , also surface and production casing heads are below ground level . There is gas venting from below ground level around well casings . I contacted Jerry Lamire with Cambrian Hunter , I advised him of findings [ idle well , gas leak ] , He said he would repair gas leak immediately and plug well when ground conditions allow it . NOTE : Well is located in a low area which has standing water over entire well site . REMEDIAL WORK REQUIRED : REPAIR GAS LEAK , PLUG OR PRODUCE WELL .
1879336760 2014-09-29 Plug / Plug Back No Violations Complaint # 4063, Bill Abell. I was on site to witness the plugging of this well. Upon completion of plugging this well the compliance notice has been resolved. NO VIOLATIONS.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1176167724 US-OH-104672 2013-02-05 Well insufficiently equipped to prevent escape of oil and gas
1176167724 US-OH-104673 2013-02-05 Defective casing, leaking well

For data sources see[5]