Well Details

Well ID: 34-093-20533
Loading map...
Country: United States
State: Ohio
County: Lorain
Municipality: Pittsfield Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: HEIDEN EH & MCCONNELL ER
License Status: Storage Well
License Date:
Spud Date: 1947-09-29
Spud Drilling Contractor:
Final Drill Date: 1947-10-23
Well Total Depth: 2189 ft
Configuration: Vertical
Latitude: 41.225705451
Longitude: -82.20687175

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1947-09-29
Completed 1947-10-23
Reached Total Depth 1947-10-23
Record Last Modified 2013-04-10

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 COLUMBIA GAS TRANSMISSION LLC 0 0 0
2002 COLUMBIA GAS TRANSMISSION LLC 0 0 0
2003 COLUMBIA GAS TRANSMISSION LLC 0 0 0
2004 COLUMBIA GAS TRANSMISSION LLC 0 0 0
2005 COLUMBIA GAS TRANSMISSION LLC 0 0 0
2006 COLUMBIA GAS TRANSMISSION LLC 0 0 0

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2002 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2003 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2004 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2005 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2006 COLUMBIA GAS TRANSMISSION LLC Brine 0 0

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0218505674 2015-01-05 Storage Well No Violations Performed annual inspection for Columbia Gas Storage Well #8479 on 01/05/2015. The well is equipped with a wellhead with 1-master valve and 1-wing valve, a drip tank, and 1-10 bbl plastic tank. Well identification is posted, but the API Number listed is incorrect. Tyler Small, Columbia Gas Team Leader, was notified of this issue and will address it promptly. No other problems were noted at the time of the inspection.
0416229843 2018-05-16 Storage Well No Violations Conducted Annual Compliance inspection for this Columbia Gas Storage well #8479. The well identification is clearly post. No compliance issues were found at time of this inspection.
0804275712 2013-11-26 Storage Well No Violations Performed annual storage well inspection for Columbia Gas Storage Well #8479 on 11/26/2013. Storage well is equipped with a 5-bbl plastic tank. Well identification is clearly posted. No problems were noted at the time of the inspection.
0981685363 2013-02-11 Storage Well No Violations I inspected Columbia Gas Transmission storage well # 8479 today. The well is located in the Wellington Storage Field, Pittsfield Township, Lorain County, Ohio. The well is equipped with a main valve, side valve with a 3.00 line to the drip tank. There is a 1.00 line from the drip tank to a 5 BBL storage tank. All lids and hatches are closed and secure. The well is properly tagged and is identified with a clear, legibly marked well identification sign mounted on the drip tank. No violations found.
1318788649 2017-10-04 Storage Well No Violations Conducted annual compliance inspection for this Columbia Gas Storage Well #8479. This well is equipped with a wellhead with 1-master valve and 1-wing valve, a drip tank, and 1-10 bbl. plastic tank. Well identification is clearly displayed on the drip bottle near the well head. No compliance issues were found at the time of this inspection.
1383050258 2016-02-02 Storage Well No Violations Inspected Columbia Gas Storage Well #8479 on 02/02/2016. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, a drip tank, and 1-5 bbl plastic tank. No dike is present. Tyler Small, Columbia Gas Team Leader, was notified of this issue and will have it addressed promptly. Well identification is clearly displayed. No other problems were noted at the time of the inspection.
1530156134 2017-07-19 Storage Well No Violations Conducted annual inspection for this Columbia Gas Storage Well #8479. This well is equipped with a wellhead with 1-master valve and 1-wing valve, a drip tank, and 1-10 bbl. plastic tank. Well identification is posted. No compliance issues were found at the time of this inspection.
1710203510 2014-01-16 Storage Well No Violations Performed annual inspection for Columbia Gas Storage Well# 8479 on 01/16/2014. Well is equipped with a drip tank and 1-5 bbl plastic tank. Well identification is clearly displayed. No problems were noted at the time of the inspection.

For data sources see[8]