If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-22088 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.338862973,"lon":-81.74162062,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Cuyahoga | |
Municipality: North Royalton | |
Operator Name: PIN OAK ENERGY PARTNERS LLC | |
Well Pad ID: | |
Farm/Lease Name: HOLZMAN UNIT | |
License Status: Producing | |
License Date: 2008-12-01 | |
Spud Date: 2009-07-21 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2009-07-26 | |
Well Total Depth: 3532 ft | |
Configuration: Vertical | |
Latitude: 41.338862973 | |
Longitude: -81.74162062 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-12-01 | Proposed Formations:ORISKANY/NEWBURG/CLINTON, Issued Date:12/1/2008, Expired Date:12/1/2009 6:00:00 AM, Drilling unit acres:21.27, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2009-07-26 | |
Completion Report Received | 2009-10-20 | |
Construction Permit Expires | 2009-12-01 | |
Change of Owner | 2018-08-21 | Operator changed from 3434, GONZOIL INC to 9722, PIN OAK ENERGY PARTNERS LLC |
Record Last Modified | 2018-08-21 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2009-11-13 | 3335 | 3390 | 21 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 72000 Gal | 48700 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | GONZOIL INC | 750 | 893 | 365 |
2011 | GONZOIL INC | 2149 | 796 | 365 |
2012 | GONZOIL INC | 1405 | 557 | 366 |
2013 | GONZOIL INC | 1082 | 437 | 365 |
2014 | GONZOIL INC | 1308 | 416 | 365 |
2015 | GONZOIL INC | 976 | 255 | 365 |
2016 | GONZOIL INC | 819 | 265 | 365 |
2017 | GONZOIL INC | 916 | 276 | 365 |
2018 | GONZOIL INC | 289 | 88 | 180 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | GONZOIL INC | Brine | 659 | 365 |
2011 | GONZOIL INC | Brine | 97 | 365 |
2012 | GONZOIL INC | Brine | 110 | 366 |
2013 | GONZOIL INC | Brine | 35 | 365 |
2014 | GONZOIL INC | Brine | 70 | 365 |
2015 | GONZOIL INC | Brine | 40 | 365 |
2016 | GONZOIL INC | Brine | 25 | 365 |
2017 | GONZOIL INC | Brine | 101 | 365 |
2018 | GONZOIL INC | Brine | 0 | 180 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0183496048 | 2014-03-25 | UrbanPreliminary Restoration | No Violations | The unit is producing with no observed problems. Load-outs are locked and entry gates are locked. The ID placard is good. No signs of leaks or problems. The lease road is well maintained. ID placards, secondary containment, and process safety equipment is present. Spacing is compliant. The 8.625 casing is accessible. |
0820711854 | 2009-07-22 | Drill / Deepen / Reopen | No Violations | rigging up on site. |
0925848756 | 2017-05-01 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery is separate chain-link enclosures located on a residential parcel, surrounded by woods . The enclosure gates were locked. Fittings and connections at both the wellhead and battery were secure. Load-line valves were plugged, locked and secure. The tank lids were closed and secure. Secondary containment was intact and the interior areas were dry and free from signs of leakage or problems. I walked and inspected the areas around the wellhead and battery and found no evidence of impact or environmental degradation relating to the on-going production activity. |
1035201231 | 2019-04-30 | Production Wells | No Violations | I conducted an inspection of the well and found no violation at well or tank battery. |
1140328054 | 2015-05-19 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection. The wellhead and battery are located in a wooded area behind a single-family home. Access to the wellhead is via the shared driveway which continues for an additional 600 feet to the wellhead. Enclosure gates are locked and secure. ID signage is present and complete. Process safety gear is present. The production tank hatches are secure. At the time of this inspection I observed the following items requiring maintenance: The electrical box is unlocked and unsecure. There is oil staining around back-pressure (Baird) valve which requires clean-up. These maintenance issues must be remedied as soon as practicable or by 06/19/2015. |
1174481982 | 2013-09-05 | UrbanPreliminary Restoration | No Violations | The producing unit consists of a producing wellhead with pumpjack and aboveground storage tank battery. The wellhead and tank battery are enclosed in separate board-on-board enclosures. The battery is comprised of one 100-barrel production tank and one 20-barrel poly brine tank. The secondary containment is good. 1501:9-9-05E safety equipment is present. There is a separate skid-mounted compressor unit located inside a third board-on-board enclosure. Unit ID is good. I did not observe any signs of leaks or spills. There is a very large, dead, red oak (48-inch diameter, 75 in height) which is beginning to lean over the tank battery. Im contacting Gonzoil to discuss possible intervention. The unit passes preliminary restoration. |
1228129370 | 2013-10-28 | UrbanProduction Wells | No Violations | I spoke with Doug Gonzalez about the dead tree over-hanging the battery. He indicated that they are aware and are making plans to cut the tree. |
1563989303 | 2016-09-28 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. At the time of this inspection, I observed the following: The wellhead is located on a residential parcel, in a partially wooded area, with the wellhead and battery located within the same clearing. The wellhead chain-link enclosure was locked and secure. Fittings and connections at the well were secure and free from signs of leakage or problems. The battery chain-link enclosure was locked and secure. The fittings and connections were secure and free from signs of leakage or problems. The load-lines were locked, plugged and secure. The secondary containment was intact and free from signs of spills, leakage, or other problems. There was a stand-alone compressor unit located within a separate, board-on-board enclosure, which was secure. I walked the areas around the wellhead and battery and noted normal growth of vegetation with no signs of impact or environmental degradation. |
1672327703 | 2011-10-31 | UrbanPreliminary Restoration | No Violations | Urban Preliminary Restoration due. Preliminary Restoration passed. |
2036397405 | 2015-06-26 | UrbanProduction Wells | No Violations | I inspected this producing unit as a follow-up to an earlier inspection. On my previous inspection, I had noted that the electrical box was unlocked and there was some staining around the Baird valve. At the time of this inspection the issues have been resolved. The electrical box is locked. The leaking Baird valve has been fixed. The wellhead and battery enclosures are locked and secure. Load-lines are locked. Process safety equipment is present and in good condition. The fittings and connections are secure and free from signs of leakage. I met with the landowner and he expressed satisfaction with the on-going operations of the producing unit and responsiveness of the well owner. He reported no complaints. |
2089847696 | 2010-02-01 | Drill / Deepen / Reopen | No Violations | checking on well site crew working on grading and planting trees. |
For data sources see[9]