Well Details

Well ID: 34-169-25234
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Congress Township
Operator Name: FUTURE PRODUCTION INC
Well Pad ID:
Farm/Lease Name: CROSS G D
License Status: Producing
License Date: 1997-12-19
Spud Date: 1997-11-07
Spud Drilling Contractor: G & H DRLG
Final Drill Date: 1997-11-15
Well Total Depth: 5302 ft
Configuration: Vertical
Latitude: 40.977131733
Longitude: -82.09012215

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1997-11-07 RBDMS Rec
Completed 1997-11-15 RBDMS Rec
Reached Total Depth 1997-11-15 RBDMS Rec
APP 1997-12-19 Proposed Formations:TREMPEALEAU-MT. SIMON, Issued Date:12/19/97, Expired Date:12/19/98 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EDPW
Construction Permit Expires 1998-12-19 RBDMS Rec
Completion Report Received 1999-01-21 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1999-04-01 2946 2968 16
1999-04-01 5207 5221 6

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 300 Gal 0 TPL DRY AFTER TREATMENT…PB TO CLINTON
H2O 0 45940 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1998 DUCK CREEK ENERGY INC 1309 0 365
1999 DUCK CREEK ENERGY INC 616 0 365
2000 DUCK CREEK ENERGY INC 2295 0 365
2001 FUTURE PRODUCTION INC 665 0 355
2002 FUTURE PRODUCTION INC 789 0 365
2003 FUTURE PRODUCTION INC 699 0 365
2009 FUTURE PRODUCTION INC 589 0 364
2013 FUTURE PRODUCTION INC 254 0 305
2014 FUTURE PRODUCTION INC 256 5 364
2015 FUTURE PRODUCTION INC 212 2 274
2016 FUTURE PRODUCTION INC 43 5 91
2017 FUTURE PRODUCTION INC 21 0 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1998 DUCK CREEK ENERGY INC Brine 0 365
1999 DUCK CREEK ENERGY INC Brine 0 365
2000 DUCK CREEK ENERGY INC Brine 0 365
2001 FUTURE PRODUCTION INC Brine 49 355
2002 FUTURE PRODUCTION INC Brine 0 365
2003 FUTURE PRODUCTION INC Brine 80 365
2009 FUTURE PRODUCTION INC Brine 35 364
2013 FUTURE PRODUCTION INC Brine 43 305
2014 FUTURE PRODUCTION INC Brine 39 364
2015 FUTURE PRODUCTION INC Brine 28 274
2016 FUTURE PRODUCTION INC Brine 36 91
2017 FUTURE PRODUCTION INC Brine 53 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0518843943 2018-06-15 Production Wells No Violations Inspected production well on 06/15/2018 at the request of Supervisor Terry Whitehair to follow-up on Chiefs Order #2014-459. The tank battery consists of 1-100 bbl steel tank, 1-1,600 gal plastic tank, and 1-horizontal separator, located within an earthen dike. The tank battery is used by multiple wells (2), however well identification is only displayed for one of the wells utilizing it. The well is a rabbit well. Well identification is posted at the wellhead, however it very faded. A Do Not Operate tag dated 05/09/2018 was also noted at the wellhead. At the time of the inspection, it was noted that the line from the wellhead to the separator was open, however the tubing head was shut-in at the wellhead. As all noted wellhead valves were shut-in, the well is not currently in production, in accordance with Chiefs Order #2014-459. No other problems were noted at the time of the inspection.
0939894781 2016-12-05 Production Wells No Violations Inspected production well on 12/05/2016. The tank battery consists of 1-100 bbl steel tank and 1-horizontal separator, located within an earthen dike. The tank battery is used by multiple wells (2), however well identification is only posted for one of the wells utilizing it. The well is rabbit well. No well identification is posted at the wellhead as required. The operator, Future Productions, was notified of these issues and will address them promptly. No other problems were noted at the time of the inspection.
1057842392 2019-04-22 Production Wells No Violations Inspected production well on 04/22/2019 to follow-up on Chiefs Order #2014-459. The well is a rabbit well that was shut-in at the time of the inspection. Well identification is posted at the wellhead, but the permit number posted on it is incorrect. A phone call to Future Production was un-returned as of 05/06/2019. No other problems were noted at the time of the inspection.
1137977990 2016-12-05 Preliminary Restoration No Violations Inspected production well on 12/05/2016. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes.

For data sources see[9]