34-011-20103

Well Details

Well ID: 34-011-20103
Loading map...
Country: United States
State: Ohio
County: Auglaize
Municipality: St. Marys Township
Operator Name: INNEX OIL AND GAS INC
Well Pad ID:
Farm/Lease Name: ELSHOFF (SWIW #1)
License Status: Final Restoration
License Date: 2013-02-07
Spud Date: 2010-02-23
Spud Drilling Contractor:
Final Drill Date: 2010-03-10
Well Total Depth: 3075 ft
Configuration: Vertical
Latitude: 40.543053351
Longitude: -84.36096315

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-02-09 Proposed Formations:MT. SIMON, Issued Date:2/9/2010, Expired Date:2/9/2011 6:00:00 AM, Drilling unit acres:10, Proposed Well Type:SWD, Proposed Well Class:SWIW
Reached Total Depth 2010-03-10 STATUS BASED ON LOGS REC'D
Annulus Pressure Monitoring Approved 2010-04-01 STATUS BASED ON LOGS REC'D
Last Compliance Report 2010-05-04 STATUS BASED ON LOGS REC'D
APP 2013-02-07 Proposed Formations:MT. SIMON SANDSTONE, Issued Date:2/7/2013, Expired Date:2/7/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:SWD, Proposed Well Class:SWIW
Plugged/Abandoned 2013-04-04 STATUS BASED ON LOGS REC'D
Construction Permit Expires 2015-02-07 STATUS BASED ON LOGS REC'D
Record Last Modified 2015-09-24 STATUS BASED ON LOGS REC'D

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0164653730 2010-09-30 Production Wells No Violations Check well and storage.

Id posted by the well head. Preliminary restoration not done, top soil still stock piled around the site.

0293824688 2011-11-21 Salt Water Injection Well No Violations Inspect well. Well shut in. Tanks have rust holes. Replacement fiberglass tanks on order. No ID at Tanks. Advised operator that well will need to be tested once a month and data recorded, because pressure leaks off within several days.
0312890608 2013-04-01 Plug / Plug Back No Violations At the time of the inspection Jet Wire Line Services were on site for a cement bond log on the 5.5 casing. The top of the cement from the bottom plug set on 3-22-13 was tagged at 2513. The bond log showed good cement behind the casing at 2290 and some partial cement up to 2200. The casing was then shot by Jet Wire Line at 2127 and removed from the well.
0395588498 2013-05-21 Final Restoration No Violations At the time of the inspection all plugging operation were completed and all equipment had been removed from the location. The location is in a farm field and was graded by the plugging contractor. The location was tilled and planted by the landowner. Final Restoration Passed.
0477928497 2013-01-17 Salt Water Injection Well No Violations At the time of my inspection the well was being used to inject the water recovered from the release on 1-12-2013. Detailed records of all fluids injected are to be kept by Allied Environmental and Innex Oil and Gas Inc.
1269056497 2012-03-08 Salt Water Injection Well No Violations Inspect Well. Injector rate of 60 bbl/day.
1273849339 2010-05-14 Salt Water Injection Well No Violations On site to witness Mechanical Integrity Test.

Pulled the tubing and packer. Cleaned the drill mud from the well. Put a 40,000lb shear ring on the packer and ran it back into the hole. Put in 500gal of acid. Unseat the packer and put in 1000gal of fresh water and inhibitor, reset the packer at the same depth and pressure up on the annulus to 1000psi and held for 15 min. test. Lost 10 psi for a final pressure of 990 psi. Past test.

1311187720 2011-06-16 Preliminary Restoration No Violations An inspection conducted with Will Ziegler revealed that the Pre-liminary Restoration meets ORC 1509.072. No violations were noted.
1351777087 2012-10-29 Salt Water Injection Well No Violations At the time of my inspection the pressure on the annular space between the 5.5 casing and the 2 3/8 tubing was pressured up to 140 psi. In five minutes the pressure was at 138 and at 15 minutes it was at 136 psi. This represents a 2.8% loss over 15 minutes. The annulus was pressured to 250 psi at 8 am and my test was done at noon on the same day. The drop from 250 psi to 140 psi over a four hour period represents a 3% loss. The operator of the well believes that the 5.5 longstring casing was not connected tightly and the annulus is losing pressure to formations behind the casing that are not cemented. At the time of my inspection the well was shut in due to a leak in the flow line from the pump to the well but during normal operation pressures in the tubing exceed 800 psi with no sign of lost pressure into the annulus.
1366893871 2013-04-04 Plug / Plug Back No Violations At the time of the inspection the well had been bailed down to 575, 125 below the surface casing, and filled from the surface with approximately 5 yards of 9 sack grout from St. Henry Tile Co.
1424138826 2013-03-22 Plug / Plug Back No Violations At the time of the inspection a bottom plug was set in the well from 2900 to 2515 with 45 sacks of 50/50 pozmix from PetroSet Cementing Services.
1504942545 2011-06-16 Production Wells No Violations I inspected the well location with Brent Bear. See Bears report for details.
1738332536 2013-01-30 Salt Water Injection Well No Violations At the time of my inspection the well was being used to inject fluids collected during the release associated with Complaint #4186. Mark Amell of Amell Inc. was hired to oversee the plugging of the well for Innex Oil and Gas Inc. as soon as the remaining fluids have been injected.
1808706409 2012-04-30 Salt Water Injection Well No Violations Inspect Well.
1825346400 2012-09-11 Preliminary Restoration No Violations At the time of my inspection, Preliminary Restoration was passed.
1848265083 2012-09-11 Salt Water Injection Well No Violations At the time of my inspection both the annular space and the tubing were on a vacuum. I contacted the operator who indicated the well is shut in due to a leak in the line from the pump to the well. The operator will set up a time to test and service the well and will contact the necessary inspectors prior to doing so.
2037892039 2013-04-03 Plug / Plug Back No Violations At the time of the inspection a plug was set across the Trenton from 1300 to 900 with 80 sacks of 50/50 pozmix from PetroSet Cementing Services. The cement was pumped through 1.5 tubing and no circulation was observed. The cement will be tagged with the bailer after 24 hours to determine the top of the plug.