X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-075-61211

Well Details

Well ID: 34-075-61211
Loading map...
Country: United States
State: Ohio
County: Holmes
Municipality: Richland Township
Operator Name: WHITNEY THOMAS C
Well Pad ID:
Farm/Lease Name: CRIDER R
License Status: Producing
License Date:
Spud Date:
Spud Drilling Contractor:
Final Drill Date: 1918-04-29
Well Total Depth: 3003 ft
Configuration: Vertical
Latitude: 40.462454345
Longitude: -82.17474651

For data sources see[1]

Well History

Well Status Well Status Date Comment
Completed 1918-04-29
Reached Total Depth 1918-04-29
Record Last Modified 2017-02-15

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1998 WHITNEY THOMAS C 0 138 365
1999 WHITNEY THOMAS C 0 170 365
2000 WHITNEY THOMAS C 0 77 365
2001 WHITNEY THOMAS C 0 78 365
2002 WHITNEY THOMAS C 0 83 365
2003 WHITNEY THOMAS C 0 83 365
2004 WHITNEY THOMAS C 0 93 365
2005 WHITNEY THOMAS C 0 52 365
2009 WHITNEY THOMAS C 0 60 365
2010 WHITNEY THOMAS C 0 0 0
2011 WHITNEY THOMAS C 0 0 0
2012 WHITNEY THOMAS C 0 45 180
2013 WHITNEY THOMAS C 0 0 0
2014 WHITNEY THOMAS C 0 30 52
2015 WHITNEY THOMAS C 0 54 365
2016 WHITNEY THOMAS C 0 53 365
2017 WHITNEY THOMAS C 0 154 365

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1998 WHITNEY THOMAS C Brine 0 365
1999 WHITNEY THOMAS C Brine 0 365
2000 WHITNEY THOMAS C Brine 0 365
2001 WHITNEY THOMAS C Brine 0 365
2002 WHITNEY THOMAS C Brine 0 365
2003 WHITNEY THOMAS C Brine 0 365
2004 WHITNEY THOMAS C Brine 0 365
2005 WHITNEY THOMAS C Brine 0 365
2009 WHITNEY THOMAS C Brine 0 365
2010 WHITNEY THOMAS C Brine 0 0
2011 WHITNEY THOMAS C Brine 0 0
2012 WHITNEY THOMAS C Brine 0 180
2013 WHITNEY THOMAS C Brine 0 0
2014 WHITNEY THOMAS C Brine 0 52
2015 WHITNEY THOMAS C Brine 0 365
2016 WHITNEY THOMAS C Brine 0 365
2017 WHITNEY THOMAS C Brine 0 365

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0543300076 2012-04-03 Production Wells Violations Noted Well is not producing,. No production reported since 2009. Old standard derrick with Pump jack under it. Electric is disconnected. Area around well is poorly kept. No ID on tank or well. Produce or plug or sell the well. Affix a valid legible ID to the well or tank. Failure to comply with this request may result in forfeiture of bond.
0866889500 2015-01-14 Production Wells No Violations The standard derrick has been removed. The pump jack is back together and the well was pumping at the time of the inspection. The compliance notice of 4/3/2012 is satisfied. There were no problems noted t the time of the inspection.
1498759917 2017-06-29 Production Wells Violations Noted Went to the location and saw what looked to be a stain in the limestone drive way starting at the stock tank for the above well. The stain went down the drive approximately 50 in both wheel tracks. The water was completely absorbed in the drive. It did not appear to get off the drive. The landowner came down to see what I was doing and said that this had happened before. The salt drain is tied in to a plastic line that goes in to a horizontal tank but you could see there was erosion of the earth between the tanks. There were also several open containers with a little oil in them that will be on the ground after the containers fill up with rain water. I contacted the operators wife and left a message and tried to contact the operator on his cell but got no answer and could not leave a message. I called Don Ridgeway his pumper and told him about the situation and he will remove the open containers and be more careful when draining water to keep it out of the environment.
1531921457 2018-07-18 Production Wells No Violations This is a follow up inspection to compliance notice 1498759917 issued on 06/29/2017. The compliance has been resolved. The On the day of my inspection I found an 8 5/8 inch diameter casing, a 4 1/2 inch diameter casing, and 2 3/8 inch diameter tubing. The well is operated by a pumping unit with an electric motor. The production equipment is made up of two 100 bbl. steel tanks, a 75 bbl. steel tank. The tanks are properly identified. The production reporting is up to date.
1656111138 2012-05-02 Production Wells No Violations Still no identification and the well is still not producing.
2081339201 2012-07-11 Production Wells No Violations An engine has been installed on the pumping unit but it is still not producable, as there is a come-a-long holding the horse head to the frame. I will attempt to contact the operator.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0543300076 US-OH-125954 2015-01-20 Failure to legibly identify well
0543300076 US-OH-125955 2015-01-20 Nonproduction; well shall be plugged or placed in temporary inactive status
1498759917 US-OH-114083 2017-08-31 9-1-07 Well operation causing pollution and contamination

For data sources see[7]

References