34-055-21789

Well Details

Well ID: 34-055-21789
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Parkman Township
Operator Name: EXCALIBUR EXPLORATION INC
Well Pad ID:
Farm/Lease Name: HOFSTETTER
License Status: Producing
License Date: 2003-11-14
Spud Date: 2004-01-19
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2004-01-25
Well Total Depth: 4254 ft
Configuration: Vertical
Latitude: 41.367487494
Longitude: -81.08377995

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2003-11-14 Proposed Formations:ORISKANY/NEWBURG/CLINTON, Issued Date:11/14/2003, Expired Date:11/13/2004 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2004-01-19 RBDMS Rec
Completed 2004-01-25 RBDMS Rec
Reached Total Depth 2004-01-25 RBDMS Rec
Completion Report Received 2004-03-23 RBDMS Rec
Construction Permit Expires 2004-11-13 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-06-08 4061 4107 32

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 69313 Gal 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 EXCALIBUR EXPLORATION INC 283 253 92
2005 EXCALIBUR EXPLORATION INC 3485 988 365
2006 EXCALIBUR EXPLORATION INC 1595 864 365
2007 EXCALIBUR EXPLORATION INC 838 421 334
2008 EXCALIBUR EXPLORATION INC 1049 531 335
2009 EXCALIBUR EXPLORATION INC 631 356 334
2010 EXCALIBUR EXPLORATION INC 725 354 365
2011 EXCALIBUR EXPLORATION INC 248 339 365
2012 EXCALIBUR EXPLORATION INC 121 285 366
2013 EXCALIBUR EXPLORATION INC 71 263 365
2014 EXCALIBUR EXPLORATION INC 438 300 365
2015 EXCALIBUR EXPLORATION INC 532 240 365
2016 EXCALIBUR EXPLORATION INC 483 180 365
2017 EXCALIBUR EXPLORATION INC 550 205 365
2018 EXCALIBUR EXPLORATION INC 573 230 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 EXCALIBUR EXPLORATION INC Brine 532 92
2005 EXCALIBUR EXPLORATION INC Brine 916 365
2006 EXCALIBUR EXPLORATION INC Brine 547 365
2007 EXCALIBUR EXPLORATION INC Brine 330 334
2008 EXCALIBUR EXPLORATION INC Brine 328 335
2009 EXCALIBUR EXPLORATION INC Brine 279 334
2010 EXCALIBUR EXPLORATION INC Brine 294 365
2011 EXCALIBUR EXPLORATION INC Brine 57 365
2012 EXCALIBUR EXPLORATION INC Brine 214 366
2013 EXCALIBUR EXPLORATION INC Brine 72 365
2014 EXCALIBUR EXPLORATION INC Brine 251 365
2015 EXCALIBUR EXPLORATION INC Brine 107 365
2016 EXCALIBUR EXPLORATION INC Brine 153 365
2017 EXCALIBUR EXPLORATION INC Brine 70 365
2018 EXCALIBUR EXPLORATION INC Brine 134 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0070395314 2004-01-20 Drill / Deepen / Reopen No Violations Rig moved on trouble setting conductor had to dit metal end of conductor closed off .
0701596143 2018-07-25 Production Wells No Violations At the time of this inspection, the well was equipped with a pumping unit. The valve on the tubing and flow line was open. The production records for this well were current. The tank battery consisted of one 100 BBL tank and a mechanical separator. Valves on the separator were open. The tank battery was diked and had legible signage. The lease access was stable.
1006368033 2012-07-06 Production Wells No Violations My inspection today found the pump unit well, tank battery and lease road in good repair.
1074609817 2004-01-20 Drill / Deepen / Reopen No Violations
1328990121 2007-06-07 Preliminary Restoration No Violations One 210 BBL one 110BBl tank on site, Heat treat separator on site, heating lines are not hooked up. Well head has a pump jack. Well head is leaking company needs to fix leak and clean up oil. Old pump jack on site needs removed. Site is graded and seeded, vegetation is established. Operator has well marked as 1787, last number on the permit sign needs fixed. Called John Smit, he will have oil cleaned up and well sign corrected. They are storing pump jack on site until next well is drilled. Restoration is passed. Sign and oil leak are production issues.
1364990630 2013-04-03 Production Wells No Violations My inspection found today that the water around the well had had been pumped out and the seal around the 4.5 had been tightened down and was not leaking. Nothing else has changed since my last inspection.
1387221918 2013-03-27 Production Wells No Violations My inspection found the well to be equipped with a pump jack. The wellhead was surrounded by a dike that was filled with water. The seals around the 4.5 inch pipe were leaking. I advised John Smit the well tender of the issue. He stated he would have it corrected tomorrow. The tank battery is in good repair. The tank battery consists of a 210 BBL production tank, a 100 BBL brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition.

For data sources see[9]

References